Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Bi-Directional: Tico 007 Multifunctional Counter - Tico 732

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Multifunctional Counter - tico 732

007
Bi-directional
■ high-contrast LED or LCD-Display, 6 digits
■ small and compact DIN dimensions 48 x 48 mm
■ easy operation by one key per digit
■ direct access to parameters
■ available with 1 or 2 presets
■ transistor and relay with changeover contact, for each preset
■ with integrated separate totalizer
■ 5 basic functions easily programmable: counter, tachometer, time counter,
shift counter and batch counter
■ display range from – 99999 to 999999

Counters
Preset
PROGRAMMING

6 R 4
count mode F1 F2 PSC PRG Reset F1 F2 PSC PRG

E 1 E 2 E 3 E 5 E 6
and POWER ON and POWER ON

E E E E E
> 5 sec

preset 1 preset 2 prescaler function-parameter e.g. Basic-


function*

count mode
decimalpoint
counter
F1 PRG F2 PRG PSC PRG
reset/set-mode tachometer
signal length time counter
pnp/npn-selection shift counter
reset mode batch counter
output memory
time counter- * only for
tachometer multifunction
programming mode keylock for: version
manual reset
preset 1 or 2
prescaler

The important values, preset 1, preset 2, prescaler and separate totalizer can be
directly selected. It is necessary only to press the relevant button and the E-button
together. To make the operation still more easy, access to those values can be locked
separately.

All other system parameters like operation and count modes are laid down in a com-
mon operation level. These parameters are usually programmed once only during the
first initiation.

Components 2003/2004 ENCODERS C O U N TE R S CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS 127


tico 732 Technical data

TECHNICAL DATA Display LED or LCD, 6 digits, leading zero suppression, decimal point
Digit height LED 7.6 mm; LCD 9 mm
Supply voltage 12...24 VDC; 24 VAC; 115 VAC; 230 VAC; 50/60 Hz, depending
General on version
Current consumption 12...24 VDC < 150 mA
100/115/230 VAC < 50 mA; including sensor supply
Sensor supply only when AC operated: 12 ... 30 VDC, max 50 mA
Data retention non-volatile memory > 10 years
Operating temperature 0 ... +50 °C
Storage temperature - 20 ... + 70 °C
Electrical connection screw terminals
Mounting with clamping frame
Protection class (IEC 144) front side IP 65, terminals IP 20
Vibrostability 10 m/s2 (10...150 Hz) according to IEC 68-T2-6
Shock stability 100 m/s2 (18 ms) according to IEC 68-T2-27
General design according to VDE 0411, DIN 57411, protection class II
Approvals UL + CUL E 96337
Amplitude thresholds < 2 V and > 8 V or < 2 V and > 3.8 V with TTL level, max 40 VDC
Active edge programmable; positive with pnp input; negative with npn input
Pulse shape any (squarewave 1:1 for max. frequency)
Input resistance approx. 5 kOhm (static)
Counting frequency max. 5 kHz (2.5 kHz bi-directional)
Prescaler programmable from 0.001 to 9.999 (999.999)
Counter Count inputs A, B - phase discriminator with single evaluation
- differential mode (add/sub)
- count direction mode
- totalizing mode (add/add)
Pulse length min. 17 ms (30 Hz), 100 µs (5 kHz)
Control input C - manual reset possible
- external reset, static or dynamic, programmable,
pulse length > 5 ms
- automatic reset when main preset has been reached
(programmable)
Relay changeover contact max. 250 VAC / 30 VDC, min. 5 V AC/DC
max. 1 A, min. 10 mA, delay < 5 ms
Transistor pnp output 12...24 VDC max 10 mA of DC-supply; 12…30 VDC
max. 10 mA of AC-supply
Tacho Method time interval (1/Tau)
Display range 1/min or 1/sec
Min input frequency 0.125 Hz = 8 sec
Alarms 2 alarms with programmable start-up-suppression
Time-counter Time bases programmable; sec, min., h or hh.mm.ss
Resolution programmable 1; 0.1; 0.01; 0.001
Function single pulse measurement (short time meter) or cumulated
counting (hour meter)
Count mode pulse width or period measurement (start-stop)

DIMENSIONS
Dimensions in mm

plug terminal clamping frame

128 Components 2003/2004 ENCODERS C O UN TER S CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS
Technical data tico 732

DIMENSIONS

VDC 1 Rel/1 Trans VAC 1 Rel/1 Trans

Counters
Preset
VDC 2 Rel/2 Trans VAC 2 Rel/2 Trans
For versions with no output, pins 7–9 and 15-17 are not connected.

POSSIBLE VARIANTS
Display Function Outputs Power supply

Counter +
totalizier no output 12 - 24 VDC

LCD Tacho 100 VAC


1 output
(1 relay,
1 transistor

LED Time counter +


totalizer 115 VAC

2 outputs
(2 relays,
Shift counter* 2 transistors) 230 VAC

Batch counter*

ORDER INFORMATION Display Preset 12–24 VDC 24 VAC 115 VAC 230 VAC

LCD – 0 732 000 0 732 071 0 732 037 0 732 001


LCD 1 0 732 002 0 732 073 0 732 039 0 732 003
LCD 2 0 732 012 0 732 078 0 732 049 0 732 013
LED – 0 732 018 0 732 080 0 732 055 0 732 019
LED 1 0 732 020 0 732 0821 0 732 057 0 732 021
LED 2 0 732 030 0 732 087 0 732 067 0 732 031

Important: Only versions with 2 presets or without preset can be used as tachometers.