2/2-Way Solenoid Valve, Direct-Acting: Type 741

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

2/2-Way Solenoid Valve, Direct-acting Type 741

G 1/4, G 1/2 Advantages/Benefits

EEx ed IIC T4

Normally closed

Body material:
Brass, stainless steel

Compact design

Design/Function Applications

The Type 741 is a direct-acting Single-phase bridge and varistor are • Dosing systems
plunger-type solenoid valve, housed in a flameproof enclosure to • Analytical devices
normally closed by spring action, protection classification "d". Coil • Fuels
assisted by the fluid pressure and terminal box correspond to • Petrochemical
(circuit function A). protection classification "e ", i.e. • Compressed air motors
increased safety. • Offshore-technology
When energized, the solenoid • Vacuum
armature is drawn in against the The solenoid epoxy encapsulation
spring to open the valve. efficiently dissipates the heat
generated by the coil.

Fluid Control Systems


2/2-Way Solenoid Valve, Direct-acting Type 741

Technical Data

Circuit Function Body Materials

A 2/2-way valve, Body of brass


Normally closed Body and seat 1.4410
Valve internals 1.4105, 1.4303

PTB.-No. Ex-88.B.1049
Specifications
2)
Orifice Kv-Value QNn-Value Pressure Range Weight
1)
DN Water Air
[mm] [m 3 /h] [l/min] [bar] [kg]
2 0,12 130 0-22 0,90
4 0,50 540 0- 4 0,90
6 0,80 860 0- 1 0,90
10 1,50 1600 0- 0,2 0,90
1)
Measured with 6 bar upstream pressure and 1 bar pressure drop across the valve at +20 °C, 2)
Also suitable for technical vacuum.

All pressures quoted are gauge pressures with respect to the prevailing atmospheric pressure.

Operating Data (Valve) Operating Data (Actuator)

Seal Materials / Fluids Handled / Temp.-Range Operating voltages 240, 220, 110, 24 V/UC
(universal current)
NBR Neutral fluids, e.g. compressed air, gas, water, A bridge rectifier has been incorporated in the solenoid
hydraulic oil, oils and fat without additives, system, which makes it suitable for both direct and
town gas -10 to+90 °C alternating current operation for the same nominal voltage
(universal current to DIN 40 700).

FPM Hot air, oxygen, per-solutions, hot oils, oils with Voltage tolerance ±10 %
additives
-10 to +90 °C Power consumption 10 W (hold)

For more detailed information please refer to resistance Rating IP 65


chart (Leaflet-No. 1896009).
Duty cycle 100% continuously rated
Max. ambient temperature +40 °C
Cycling rate up to 600 c.p.m. depending
Max. viscosity approx. 21 mm /s 2 on operating pressure

Response times opening approx. 30 ms


closing approx. 60 ms Installation / Accessories

Installation as required, but preferably


The response times have been measured with water at a
with solenoid system
working pressure of max. 6 bar. They depend upon
upright
pressure and viscosity of the fluid handled.

Electrical connection • moulded-in cable H05RN-


F3 G, 3 x 0,75 mm2,
length 3 m, with tension
relieving cable gland
• junction box on request

Safety fuse A safety fuse with a medium


response time and rated
according to the nominal
current should be
incorporated in the circuit.
The nominal current rating is
printed on the actuator.
2/2-Way Solenoid Valve, Direct-acting Type 741

Dimensions in mm

24

18

56
45,5
6

80
100

93
3000

17
NPT 1/4
G 1/4
SW 27
48

34,5
12 bei G 1/4
10 bei NPT 1/4
74,5

Brass body DN 2 - 6
Stainless steel body DN 4 - 10
11

40
10,8
Ø26

28
56

76
93

80

6,5

14
G 1/4
G 3/8

37
SW 22
56

Brass body DN 10
2/2-Way Solenoid Valve, Direct-acting Type 741

Ordering Chart (Other Versions on Request)

Circuit Orifice Flow Rate Port Pressure Body Seal Weight Voltage/ Order-No.
2)
Function Water Air Connect. Range Material Material Frequency
DN Kv-Value QNn
[mm] [m 3 /h] [l/min] [mm] [bar] [kg] [V/Hz]
A 2,0 0,12 140 G 1/4 0-22 Brass NBR 0,90 024/UC 089 473 Z
110/UC 089 474 S
220/UC 089 475 T
240/UC 089 476 U

4,0 0,50 540 G 1/4 0- 4 Brass NBR 0,90 024/UC 089 450 E
110/UC 089 451 T
220/UC 089 452 U
240/UC 089 453 V
Stainless FPM 0,90 024/UC 059 095 T
110/UC 076 299 D
220/UC 087 290 U
240/UC 076 300 J

6,0 0,80 860 G 1/4 0- 1 Brass NBR 0,90 024/UC 089 466 S
Brass NBR 0,90 110/UC 089 467 T
Brass NBR 0,90 220/UC 089 468 C
Brass NBR 0,90 240/UC 089 469 D
Stainless FPM 0,90 024/UC 076 301 F
110/UC 076 302 G
220/UC 076 303 H
240/UC 076 304 A

10,0 1,50 1600 G 1/2 0- 0,2 Brass NBR 0,90 024/UC 076 294 Y
110/UC 076 295 Z
220/UC 076 297 T
240/UC 076 298 C
Stainless FPM 0,90 024/UC 057 297 Y
110/UC 076 305 B
220/UC 085 932 H
240/UC 076 306 C
1)
Measured with 6 bar upstream pressure and 1 bar pressure drop across the valve at +20 °C, 2)
Also suitable for technical vacuum.

Order-No. for Accessories

Safety Fuses [mA] Order-No.

24 V 1000 007 077 V


110 V 315 007 055 X
220/240 V 160 007 070 A

In case of special requirements We reserve the right to make technical 710-GB/ 2-0117
please consult for advice. changes without notice.