Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Operating Manual of Multihead

Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

OPERATION MANUAL OF

MULTIHEAD WEIGHER

Page 1 of 62
PREFACE

Multihead weigher is automatic weighing equipment by using


MCU control system to achieve high speed, accuracy and
stable performance. Different function could be expanded
according to customer’s requirements.

To ensure proper use and safe operation, please refer this


operation manual carefully before using. This manual contains
most of the instruction that how to start machine and setup
parameters.

If any problem arises while using Multihead weigher machine,


please feel free to contact our service department. We will try
our best to provide you a professional service.

NOTICE

Working Environment:
 Temperature: 0° - 45°C.
 Humidity: 35% - 85% none condensing.
 Keep away from the disturb source.
 Installation place should on rigid, horizontal and no
vibration surface.
 Leave enough space around machine for maintenance.

DO’s and DON’Ts

 Only professional engineer is allowed to repair the


machine when failure happens.
 Turn off the main power while cleaning, moving or
repairing the machine.
 Avoid bumping or strong pressure on weigh hoppers.
 The machine should be treated carefully while
transporting, installation and disassembling. Prevent from
strong vibration.

Page 2 of 62
Chapter 1 Introduction

Main components………………………………………………………..5
Working Theory………………………………………………………….7

Chapter 2 Connection

Synchronizing with packaging machine……………………………….8

Chapter 3 Operation
Startup Procedure………………………………………………………10
Page Configuration……………………………………………………..12
Home Menu……………………………………………………………..13
Program Copy…………………………………………………………..16
Automatic Run…………………………………………………………..19
Manual Test……………………………………………………………..25

Chapter 4 Weigher setup


Program Setup………………………………………………………….28
Setup 1……………………………………………………………30
Setup 2……………………………………………………………33
Setup 3……………………………………………………………36
Setup 4……………………………………………………………38
Setup 5……………………………………………………………41
Calibration……………………………………………………………... 42
Summary……………………………………………………………….. 44

Page 3 of 62
Chapter 5 System Configuration

System Setup……………………………………………………………46
Setup 1………………………………………………………….... 47
Setup 2…………………………………………………………… 49
Setup 3…………………………………………………………….51
Setup 4…………………………………………………………….52
Setup 5…………………………………………………………….53
About…………………………………………………………………….. 54
Password………………………………………………………………... 55

Chapter 6 Error

Error Description…………………………………………………………57

Page 4 of 62
CHAPTER 1 INTRODUCTION

This Chapter gives brief introduction of Multihead weigher


machine.

MAIN COMPONENTS

Main Vibrator:
Main vibrator is the vibrating source for the top cone, from top
cone; product will be distributed to linear vibrator pan.

Linear Vibrator:
Linear vibrator is the vibrating source for the linear vibrator pan;
product will be distributed to intermediate hopper (feed hopper).

Page 5 of 62
Intermediate (Feed) Hopper:
Intermediate (feed) hopper receives products from linear
vibrator. It will discharge product to weigh hopper which is
below it, when weigh hopper is empty.

Weigh Hopper:
Each weigh bucket is connecting to load cells and it will read
weight of product inside the weigher, and controller will use the
weighted data to make combination. Selected weigh hopper will
discharge products to the collecting hopper or machine.

Page 6 of 62
WORKING THEORY

The product is fed to main vibrator pan than it is distributed to


feed hopper by linear vibrator pan of each head. Each feed
hopper will drop the product into weigh hopper as soon as it
becomes empty.

The weigher computes the product weight in individual weigh


hopper and identifies which combination contains weight
closest to target weight. The Multihead weigher will open all the
hopper of this combination and product falls to the packaging
machine. The working principle of Multihead weigher is as
shown in chart.

Main vibrator pan

Linear
vibrator pan
Multihead Weigher

Feed Hopper

Weigh Hopper

Weigh Hopper
Combination

Discharge

Packaging m/c,
Conveyer etc.

Page 7 of 62
CHAPTER 2 CONNECTION

SYNCRONIZING WITH PACKAGING MACHINE

Master Mode: When Multihead weigher servers as master.

Operation Sequence:

1. Machine will set continuous signal to dump request input.

2. When combination of weigher is ready, machine sends


ready signal and drop material to machine.

3. On receiving ready signal slave machine will run single


packing cycle.

Master Slave

READY
INFEED SIGNAL
REQUEST
SIGNAL

DUMP
REQUEST
SIGNAL

Page 8 of 62
Slave Mode: When packaging machine serves as master.

Operation Sequence:

1. When combination of weigher is ready, Multihead weigher


sends the ‘ready’ signal to the packaging machine.

2. After packaging machine receives the ‘ready’ signal, it


sends ‘dump request signal’ to weigher to dump the
weight.

3. After receiving the dump request signal, Multihead


weigher dumps the weight into packaging machine.

Slave Master
DUMP
INFEED
REQUEST
REQUEST
SIGNAL
SIGNAL

READY
SIGNAL

Page 9 of 62
CHAPTER 3 OPERATION

This Chapter Explains The Daily Procedure.

STARTUP PROCEDURE

Main Power On:


Turn on the main power switch, installed in system.
After the main power is switch on, LED lights on HMI will be on.

As shown in above figure, after system initialization “Please


Press Zero” alert will display to remind you to press zero
before starting machine.

During this process all weigh hopper will open and close in
sequence to empty the residual, then the zero function will be
performed. Unless zeroing the whole machine run command
will remain locked.

Page 10 of 62
Once zero function is activated, machine will display all weigh
hopper readings.it should be steady in between -0.2 to +0.2g
after this function.

Note: Initial zero is compulsory. Only after zeroing is completed


“RUN” button will be unlocked.

Page 11 of 62
PAGE CONFIGURATION
Time & Date
Page Name Display

Page Name:

Page name identifies the content of each page.

Time & Date Display:

Local time and date will display on each page.

Page 12 of 62
HOME MENU

After initial zero is completed, “Automatic Run Mode page” will


be displayed as shown in figure.

Home Button

Page 13 of 62
Main Navigation Menu:
By pressing home button, the main navigation menu will
be activated.
From this menu user can access “Automatic Run”,
“Program Setup”, “System Setup”, “Manual Test”, “Calibration”,
“Program Copy”, “Summary”, “Password” and “About”.

Automatic Run:
Use this menu to start, stop, other operation and to
observe live statistics of the system like actual weight, target
weight, overweight, under weight, and average combination
hopper.

Program Setup:
Use this menu to change the program setting for
operation.

System Setup:
Use this menu to change the system setting for the
operation.

Manual Test:
Use this menu to perform the manual testing of all
functions of vibrators, buckets and also to check input and
output of the system.

Calibration:
Use this menu to perform calibration of all loadcells.

Program Copy:
Use this menu to backup the program in the memory or
to select the saved program for the operation.

Summary:
Use this menu to check the production summary and
error log generated during operation.

Page 14 of 62
Password:
Use this menu to change the password of setups and
calibration page.

About:
Use this menu to check the version of all cards.

Page 15 of 62
PROGRAM COPY

After initial zero process is completed, touch ‘Program Copy’


from the main navigation menu to select program for system.

On the left corner of the screen list of all program number and
respective name is given, accordingly selection of program can
be done.

Page 16 of 62
HMI>>Machine:

Press “>>” button to load preset program from HMI memory to


the machine.

Popup screen will open when this button is pressed, specify


program number, accordingly program name will display press
“Copy” button to complete process.

COPYING…

If program is copied completely then “COPYING…” message


will display as shown in above screen.

Page 17 of 62
Machine>>HMI:

Press “>>” button to backup program from machine to HMI


memory.

COPYING…

Popup screen will open when this button is pressed, specify


program number and give program name to save the program
in HMI memory.

If program is saved successfully then “COPYING…” message


will display and if any error occurs during copy then “COPY
ERROR” message will display.

Page 18 of 62
Automatic Run

Touch “Automatic Run” from main navigation window to enter


the page. Program number
Help and name

Drop
weight
Actual
Speed

Info
display

Weigher Image

RUN:
Press “RUN” button to start the operation, weigher will
start its function and “RUN” button will enable “STOP” button.
And press “STOP” button to stop the working.

When machine is in running condition “HOME” button is


invalid, user can’t switch to another window.

EMPTY:
Press “EMPTY” button to clean out all products on the
weigher. During this operation all other buttons on the screen
will be invalid except “STOP” button.
Press “STOP” button to stop empty function.

Page 19 of 62
ZERO:
When “ZERO” button is pressed, in sequence weigh
hopper will open and dump the product, reading of each head
will be zero. During this operation all other buttons on the
screen are invalid.

STOP:
Press “STOP” button to stop the operation.

INFO DISPLAY:
Following data is displayed on this page.

Program No, & Name:


This tag will display current
program number and name given to
that program.

Drop Weight:
The last weight dropped on
drop signal.

Actual Speed:
This will display the speed, at which weigher is running.

Target Wt:
The target weight is preset desired weight.

Over Wt:
The overweight is presettable maximum over weight limit
of the weighed product.

Under Wt:
The underweight is presettable minimum under weight
limit of the weighed product.

Average Comb Hopper:


The average combination hopper will display number of weigh
hopper that are selected in a combination.
Page 20 of 62
HELP:
Press “i” to activate the help menu, press again to deactivate.
Help menu explains the meaning of each colour that the image

changes during operation.

Colour Indication:

HPR : Respective hopper is deactivated.


DISABLED
DEFAULT : Respective hopper is in normal state.
FORCE DUMP : Respective hopper should be dump forcibly.
COMBINATION : Respective hoppers are in combination.
BEING FED : Respective Hoppers products are being fed.
UNDER WT : Respective Hoppers product weight is less
Than target weight.
AUTO ZERO : Respective Hopper is currently under auto
Zeroing process.
HEAD ERROR : Respective Hopper has error.
OVER WT : Respective Hoppers product weight is
Greater than target weight.
RUN CHP : Collecting hopper is in running state.

Page 21 of 62
FUNCTION ERROR:
During functions error mentioned below can be generated,
description of error are given.

Alert 1

INITIALIZATION FAIL

Alert 2:

NO COMBINATION FOUND

Page 22 of 62
Alert 3:

OVERWT COMBINATION

Alert 4:

NO HEAD FOUND

Page 23 of 62
Alert 5:

ERROR ON ALL HEAD

Alert 6:

AUX CARD ERROR

Page 24 of 62
MANUAL TEST

To test system manually, touch “Manual Test” on main


navigation menu that will open two selections “i/o check” and
“Function check”.

I/O CHECK:

Page 25 of 62
I/O Check:
To check input and output of system manually, press this
option.

To check output, press check button if output is working


properly then it will be indicated green colour as shown in
above screen.

To check input, give signal to the system, if it is working


properly then indication of that input will be displayed on the
screen.

Function Check:
Press here to check
Press here to check linear vibrator of
Main vibrator selected head

Help

Press here
to check
feed
Hopper
Press here
to check
weigh
hopper

Home Select head of which Press here to check Press here to check
function to be checked Right hopper of CHP Left hopper of CHP

Page 26 of 62
Press on the indicated place to check the
function. Once it is pressed respective
symbol will turn to Yellow, which indicates
that function is working.To enable and
disable head, press that head. It will turn
“RED”, which indicates head is disabled.
Clean:
To clean the machine, press “CLEAN” button which display on
the screen, other buttons are become invalid when cleaning
operation is running. To stop clean function, press “STOP”
button.

Once:
To run whole cycle of selected head, press “ONCE” button.

Help Info:
Meaning of color displayed on 3D weigher image is known by
pressing “i” on right top corner of the page.

This display of status can be deactivated by pressing “I” again.

Page 27 of 62
CHAPTER 4 WEIGHER SETUP
This Chapter Explains all the parameters required to setup
weigher.

PROGRAM SETUP
Touch “PROGRAM SETUP” on main navigation menu to enter
the page. There will be a password window open. Input “1111”
in password and press enter to go.

There are five setup screens in total.

PROGRAM SETUP
PROGRAM NO. 1

Page 28 of 62
Page
slection
Program
number

Program Number:
Program No. indicates the current program that is in use
for the operation.

Page Selection:
Press on the page number to go to different setup Pages.
The selected page will be display in dark grey colour.

Any changes made within the current program, will be saved


automatically.

Page 29 of 62
SETUP 1

List of parameters in setup 1 are explained below.

Target Wt.:
This is that desired weight which is achieved by the
combination. Use this parameter to set to change the target
weight for current program. Its unit is in grams.

Over Wt.:
Use this parameter to set up the overweight limit in the
combination. Its unit is in grams.

Under Wt.:
Use this parameter to set up the underweight limit in the
combination. Its unit is in grams.

Correct Wt.:
These function servers as the fast solution to correct the
weight variation. When there is consistent weight variation
caused by improper setting (delay time etc), use correction

Page 30 of 62
weight setting to bring the weight back closet to the target
weight.
I.e. if improper hopper open time causes product leakage, thus
result in consistent weight variation of 3 grams; correction
weight can be set as – 3g.

Zero Interval:
The load cell performs zeroing automatically after set time
of combination. This function aims to remove error to ensure
weighing accuracy. In Zero status, the hopper is cleared
up and will not be consider in combination. Its unit is in
minute.

Stagger Dump Time:


Stagger dump is used when the products could cause
blockage of the outlet funnel. When this function is used, weigh
hoppers selected in combination will open in sequence.
Stagger dump interval is used to set the time interval
between each bucket is opened. Its unit is ms. System will
multiply the entered value by 10 to get time in millisecond.

Over Wt. Comb alarm:


Select the processing ways in case of there isn’t any
combination.

 NO: Auto enforced dumping. If there is no any


combination the weigher computer will recalculate all
combination and identifies the overweight closest to the
target weight, discharge this overweight products and
output the "Overweight" signal.

 YES: Manual intervention. The weigher will stop and


message will be displayed “OVERWT COMBINATION”,
press “DUMP” to remove alert and system will start
combination again.
Select the processing ways in case if there isn’t any
combination.

Page 31 of 62
Required Speed:
Set an expected speed for Multihead weigher. It can be
set according to the working speed of the connected packaging
machine. Its unit is combination/minute.

Vibrator Setting:
Touch display
button to open
the vibrator
setting page,
where individually
or all together the
amplitude of
linear vibrator can
be set and main
vibrator amplitude
can be set.

Page 32 of 62
SETUP 2

List of parameters in setup 2 are explained below.

Product Feed Time:


It refers the lasting time of conveyor feeding to the
weigher; conveyor will begin to feed material after weigher
output feeding signal. After the product is fed up to the upper
limit, the feeding signal will be last signal for "Product Feed
Time" and then the weigher stop feeding output feeding signal.
Its unit is in seconds.

No Product Pause:
Weigher will pause automatically when the products on
the top cone is under the ‘signal start weight’. When the
products are over the ‘signal start weight’, weigher will restart
automatically.

Page 33 of 62
Force Dump Hopper:
This value is used as judging criteria when no qualified
combination is found. When actual underweight hoppers
exceed this value, re-combination will take place. When actual
underweight hoppers are below this value, weigher will dump
the unqualified weights.

Min Single HPR Wt.:


It is a percentage to be set. If single hopper weight is less
than certain percentages of target weight, the hopper is not
allowed to join combination and it needs feed more material.
And this hopper can attend the combination when reaching the
certain percentage.

Multi Comb Time:


When target weight is large, it will be divided into several
times to discharge. The collecting hopper will open to dump the
products into packaging equipment after collecting all the
products from the multi-combination times discharges.

CHP Mode:
1: Single timing hopper door open (the right door).
2: The two doors of timing hopper open at the same time.
3: The two doors of timing hopper open by 2input.
4: The timing hopper, one door discharge to packing
machine, the other discharge to overweight rejecter.

No Comb Repeat:
This function is used when the any weigh hopper is not
selected into combination over preset number of cycles, it will
be forced into combination the next cycle.

Page 34 of 62
WHP Move Pattern:
Set a move pattern of weigh hopper.
1: FWD-FWD
2: REV-REV
3: FWD-REV
4: REV-FWD

FHP Move Pattern:


Set a move pattern of feed hopper.
1: FWD-FWD
2: REV-REV
3: FWD-REV
4: REV-FWD

CHP Move Pattern:


Set a move pattern of weigh hopper.
1: FWD-FWD
2: REV-REV
3: FWD-REV
4: REV-FWD

Page 35 of 62
SETUP 3

List of parameters in setup 3 are explained below.

Vibrator Start Delay:


It refers the time delay that linear vibrator to feed product
to feed hopper after the feed hopper open. If it is too short
product may be blocked in feed hopper, if it is too long it will
affect weighing speed.
Its unit is millisecond.

WHP Start Delay:


It refers the time delay that weigh hopper to dump product
into collecting hopper after the collecting hopper open. Its unit
is millisecond.

Page 36 of 62
FHP Start Delay:
It refers the time delay that feed hopper to dump product
into weigh hopper after the weigh hopper open. Its unit is
millisecond.

CHP Start Delay:


It refers the time delay that collecting hopper to discharge
product into packaging machine after the weigh hopper dump
product to ensure all the material in the collecting hopper and
then allow next discharge. Its unit is millisecond.

Vibrator Run Time:


Vibrator on time. Value is to be entered as a number.
System will multiply the entered value by 10 to get time in
millisecond.

WHP Hold Time:


Time between opening and closing of weigh hopper to
ensure all products are discharged. Its unit is in millisecond.

FHP Hold Time:


Time between opening and closing of feed hopper to
ensure all products are discharged. Its unit is in millisecond.

CHP Hold Time:


Time between opening and closing of collecting hopper to
ensure all products are discharged. Its unit is in millisecond.

Page 37 of 62
SETUP 4

List of parameters in setup 4 are explained below.

Stable Time:
Use this parameter to set the time after which weight
reading is taken by the system and displayed on the HMI. Its
unit is millisecond.

Combination Mode:
This setting is used to select the combination mode that is
weigh or count. Weigh is standard mode of combination.

Auto Adjust Amp Model:


Auto Adjust Amplitude Model is used to automatically
monitor and adjust the amplitude of linear vibrators. Automatic
frequency control has three different modes: OFF, AFCT and
AFCI.
 OFF: It means to close this function. The amplitude can
only be adjusted by manual.

Page 38 of 62
 AFCT: It adjusts the amplitude according to the
combination hoppers and it will give an auto adjustment to
all linear vibrator amplitudes.
 AFCI: It adjusts the amplitude according to the individual
hopper weight and it will give an auto adjustment to the
single linear amplitude, meanwhile, display the single
amplitude.

When AFCT is selected following parameters are to be set.

Comb HPR:
It refers the average weigh hoppers which are used in a
successful combination weighing.

Single Accept Comb Error Hoppers:


It refers to the acceptable deviation of average number of
combination hoppers.

Page 39 of 62
Track Interval AFCT:
After N times successful combination cycles, it will give an
auto adjustment to all linear amplitudes.

When AFCI is selected following parameters are to be set.

Single Hopper Average Wt:


It refers to the ideal average weight of single hopper, and
it was calculated as certain percentage of single combination
weight.

Single Hopper Accept Error Wt:


It refers to the single acceptable hopper weight error
during running.

Track Interval AFCI:


After N times successful combination counts, it will give an
auto adjustment to all linear amplitudes.

Page 40 of 62
SETUP 5

PRODUCT IMAGE:

PROGRAM SETUP

PROGRAM NO. 1

Product image represents the current application in operation.

Touch the Page no.5 to activate the picture library. There are 8
pictures available from the manufacture setting. To select
product touch the suitable picture.

Page 41 of 62
CALIBRATION

Touch “CALIBRATION” on main navigation menu to enter the


page. There will be a password window open. Input “3333” in
password and press enter to go.

Page 42 of 62
Actual Weight:
On the right corner of the page, actual weight of all head
will be displayed.

Head No.:
Enter the head number of which calibration to be done.

Calibration Weight:
Enter the calibration weight. Its unit is grams.

After selecting head and entering calibration weight, press


“ZERO” during which weigh hopper will open and discharge
products, actual weight should be stable at 0.0 – 0.2g.

Place load on the weigh hopper which is to be calibrated. Then


press “SPAN” button, display weight should be stable.

Page 43 of 62
SUMMARY

Touch “SUMMARY” to enter the production summary page.

Production Summary:

Enter the Date, Month and Year of Press Production Press Error
which production summary want to view reset to clear Log to view

On this page detail of total pass bags, total over bags, average
hopper and actual speed during process will be display. Enter
the Date, Month and Year to review production detail. It can
review the production data of only past 10 days.

To clear past production Record press Production reset button.

To enter the error log page press “ERROR LOG” button on


right corner bottom of the production summary page.

Page 44 of 62
Error Log:

Error
Type Info

Enter the Date, Month and Year of which Press Summary to view
Error log want to view

On this page detail of Error name and Error type will be display.
Enter the Date, Month and Year to review production detail. It
can review the production data of only past 10 days.
When i logo pressed at right corner it will show the status of
error type.0 stands for error registered and 2 stands for error
solved.

Touch “Summary” to again enter to production summary page.

Page 45 of 62
CHAPTER 5 SYSTEM SETUP
This Chapter Explains all the parameters required to setup system.

SYSTEM SETUP
Touch “SYSTEM SETUP” on main navigation menu to enter
the page. There will be a password window open. Input “2222”
in password and press enter to go.

There are five setup screens in total.

DATE AND TIME SET

Page 46 of 62
SETUP 1

List of all parameters of setup 1 are explained below briefly.

Vibrator Setting:

DATE AND TIME SET

Vibrator Frequency:
Vibrator to be run in either half or full mode of frequency.
Select half frequency for Harder Vibration and Full frequency
Means Softer Vibration.
Acceleration Time:
Ramp up time of vibration from 0% to 100 %. Set value as
small as possible Default value.
Deceleration Time:
Ramp Down time of vibration from 100% to 0 %. Set value
as small as possible Default value.

CHP Installed:
Select YES or NO, on the basis of collecting hopper is
installed or not in the machine.

Page 47 of 62
ADC Setting:

Slave Send Wt. Time:


This is that time at which slaves send weight continuously.
Its unit is in millisecond.

SETUP 2

Page 48 of 62
List of all parameters of setup 2 are explained below briefly.

SIGNAL TYPES:

0: LEVEL TRIGGER WITH MEMORY


If Multihead weigher receives a request signal when it is
not ready, it will remember the request signal and dump the
weigher when it is ready.
1: LEVEL TRIGGER WITHOUT MEMORY
If Multihead weigher receives a request signal when it is
not ready, it will discard until both arrive at same time.
2: EDGE TRIGGER WITH MEMORY
If Multihead weigher receives a request signal when it is
not ready, it will remember the request signal and dump the

Page 49 of 62
weigher when it is ready.
3: EDGE TRIGGER WITHOUT MEMORY
If Multihead weigher receives a request signal when it is
not ready, it will discard until both arrive at same time.

Request
Ready

Dump 0
Dump
1
Dump 2
Dump 3

Wt. Signal length:


The length of Weight signal .It is primarily used when
weight signal is connected to the alarms.

Dump Signal Time:


Time at Which Multihead weigher will send dump signal to
Packaging machine.

Dump Signal Delay:


After the system dump material, there will be delay time
after which weigher will send dump signal to the packaging
machine.

SETUP 3

Page 50 of 62
In setup 3 there is weigh hopper move pattern setting, there are
four modes. And each mode has five steps of initial and return
move. This parameter setting will affect the speed of machine.

Modes can be selected by subpage selection.

Sub Page
Selection

Page 51 of 62
SETUP 4
In setup 4 there is feed hopper move pattern setting, there are
four modes. And each mode has five steps of initial and return
move. This parameter setting will affect the speed of machine.

Modes can be selected by subpage selection.

Sub Page
Selection

SETUP 5

Page 52 of 62
In setup 5 there is collecting hopper move pattern setting, there
are four modes. And each mode has five steps of initial and
return move. This parameter setting will affect the speed of
machine.

Modes can be selected by subpage selection.

Sub Page
Selection

Page 53 of 62
ABOUT

Touch “ABOUT” on main navigation menu to enter this page.

On this page version of all cards will be displayed, main card


version, auxiliary card version and version of all 10 heads slave
cards and ADC card.

Page 54 of 62
PASSWORD

Touch “Password” on main navigation menu, to enter the page.

Password to access “Program Setup” page, “System Setup”


page and “Calibration” page can be modified over here.

Press “Enter” button near


the page name of which
password to be modified.

Here password of program


setup page is modified.
Press “Enter”, popup page
will open where enter the
old password of Program
Setup page; till correct
password is not entered
“Enter” button below it will be invalid.
If correct password is entered the new popup page will open.

Page 55 of 62
Enter new password
of for program setup.
And press enter
button below it, again
confirmation will be
asked to save new
password.

Enter “Yes” to
continue and
Password to access
Program Setup page
is modified.

Page 56 of 62
CHAPTER 6 ERRORS
This Chapter Explains all type of errors indicated on HMI.

In the system error are tracked in two ways,


 Firstly if any error generated during any operation,
immediately will be popped up on page.
 Secondly on ZERO page and FUNCTION CHECK page
errors can be identified by color change on 3D image of
weigher.

ERROR DESCRIPTION

If any internal error is triggered during operation of the system it


will be popup on page.

List of Errors are described below.

Head Intrnal Error = this means that error is generated


due to ADC card of given head number.
Head Comm. Error = this means that error is generated of
communication of head with slave card of
that head.
Vib. Supply Error = this means error is generated in
vibrator section of mentioned head.
Card Comm. Error = this means communication error
between mentioned slave and main card.
Head WHP Error = this means overrun error in weigh
hopper of mentioned head.
Head FHP Error = this means overrun error in feed
hopper of mentioned head.
Aux Vib. Supply Err = this means error is generated in
vibrator section of auxiliary.
Aux Crd Comm. Err = this means communication error
between mentioned slave and main card.
AUX RHP Error = this means overrun error in right
hopper of auxiliary.

Page 57 of 62
AUX LHP Error = this means overrun error in left
hopper of auxiliary.
System Error = if slaves are not boot properly and
there is communication error then this
error is generated.
Init Error = if there is any error during initialization
then this error is triggered.
Memory Sync Error = if memory sync is not proper than this
error is generated.

Page 58 of 62
PARAMETER PAGE
PARAMETER NAME GROUP NO.

EMPTY Automatic Run 19

RUN Automatic Run 19

ZERO Automatic Run 20

STOP Automatic Run 20

Program No, & Name Automatic Run 20

Drop Weight Automatic Run 20

Actual Speed Automatic Run 20

Target Wt Program Setup1 30

Over Wt Program Setup1 30

Under Wt Program Setup1 30

Average Comb Hopper Automatic Run 20

Clean Function Check 27

Once Function Check 27

Correct Wt. Program Setup1 30

Zero Interval Program Setup1 31

Stagger Dump Time Program Setup1 31

Over Wt. Comb alarm Program Setup1 31

Required Speed Program Setup1 32

Vibrator Setting Program Setup1 32

Product Feed Time Program Setup2 33

No Product Pause Program Setup2 33

Force Dump Hopper Program Setup2 34

Page 59 of 62
Min Single HPR Wt. Program Setup2 34

Multi Comb Time Program Setup2 34

CHP Mode Program Setup2 34

No Comb Repeat Program Setup2 34

WHP Move Pattern Program Setup2 35

FHP Move Pattern Program Setup2 35

CHP Move Pattern Program Setup2 35

Vibrator Start Delay Program Setup3 36

WHP Start Delay Program Setup3 36

FHP Start Delay Program Setup3 37

CHP Start Delay Program Setup3 37

Vibrator Run Time Program Setup3 37

WHP Hold Time Program Setup3 37

FHP Hold Time Program Setup3 37

CHP Hold Time Program Setup3 37

Stable Time Program Setup4 38

Combination Mode Program Setup4 38

Auto Adjust Amp Model Program Setup4 38

Comb HPR Program Setup4 39

Single Accept Comb Program Setup4 39

Error Hoppers Program Setup4 39

Track Interval AFCT Program Setup4 40

Single Hopper Average Wt Program Setup4 40

Single Hopper Accept Err. Wt Program Setup4 40

Page 60 of 62
Track Interval AFCI Program Setup4 40

Product Image Program Setup5 41

Actual Weight Calibration 43

Head No. Calibration 43

Calibration Weight Calibration 43

Vibrator Setting System Setup1 47

Vibrator Frequency System Setup1 47

Acceleration Time System Setup1 47

Deceleration Time System Setup1 47

CHP Installed System Setup1 48

ADC Setting System Setup1 48

Slave Send Wt. Time System Setup1 48

Wt. Signal length System Setup2 50

Dump Signal Time System Setup2 50

Dump Signal Delay System Setup2 50

Signal Type System Setup2 49

Page 61 of 62
Page 62 of 62

You might also like