File No - SCR-NED0ENGG (MISC) /106/2023-O/o SR DEN CO/NED/SCR
File No - SCR-NED0ENGG (MISC) /106/2023-O/o SR DEN CO/NED/SCR
File No - SCR-NED0ENGG (MISC) /106/2023-O/o SR DEN CO/NED/SCR
SUB - SCHEDULE - AI
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including
dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the
1 2.8.1 All kinds of soil. 31.79
4.6 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc.
as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3
coarse sand), including the cost of required centering, shuttering complete.
2 4.B1 l:1'/z:3 (1 Cement : 1'Zz coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal 26.47
size).
3 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses 229.02
by weight of cement as per manufacturefs specification.
2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as di
4 2.6.1 All kinds of soil 129.19
2.7 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means
over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as
5 2.7.1 Ordinary rock 32.30
6 2.7.3 Hard rock (blasting prohibited) 48.45
7 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, 19.67
consolidating and dressing complete.
4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
10 4.1.3 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) 24.04
5.33 Providing and laying in position machine batched and machine mixed design mix M-25
grade cement concrete for reinforced cement concrete work, using cement content as per
approved design mix, including pumping of concrete to site of laying but excluding th
15 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete 123.84
15 5.9.3 Suspended floors, roofs, landings, balconies and access platform 308.46
16 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers 287.61
17 5.9.6 Columns, Pillars, Ners, Abutments, Posts and Struts 287.61
18 5.9.7 Stairs, (excluding landings) except spiral-staircases 50.40
5.9.16 Edges of slabs and breaks in floors and walls
19 5.9.16.1 Under 20 cm wide 143.70
20 5.9.19 Weather shade, Chajjas, corbels etc., including edges 23.88
19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar
in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints
etc. complete :
21 19.1.1 100 mm diameter 36.00
22 19.1.2 150 mm diameter 15.00
25 19.1.3 200 mm diameter 6.00
24 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not 100.00
exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and
lift up to 1.5 m.
25 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement 26.47
: 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
26 11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the 25.00
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick cement mo
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required
size,approved shade, colour and texture laid over 20 mm
31 13.48A.1 New work (Two or more coats applied B 1.43 litre/10 sqm. Over and including priming 1423.50
coat of exterior primer applied B 0.90 litre/10 sqm.
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
32 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 3928.31
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete above plinth level.
33 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 6744.85
34 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, 530.00
including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer all complete.
13.7 12 mm cement plaster finished with a floating coat of neat cement of mix :
35 13.7.2 1:4 (1 cement: 4 fine sand) 63.36
13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even
shade :
36 13.61.1 Two or more coats on new work. 257.02
37 12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as 15.12
approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-
18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling
etc. : External work
38 18.12.3 25 mm dia. nominal bore 30.00
39 18.12.4 32 mm dia. nominal bore 15.00
40 18.12.5 40 mm dia. nominal bore 50.00
18.13 Making connection of G.I. distribution branch with G.I. main of foflowing sizes by
providing and fixing tee, including cutting and threading the pipe etc. complete :
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:
733 and IS: 1285, fixing with dash fasteners o
21.1.1 For fixed portion
48 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, 120.00
Minimum anodic coating of grade AC 15)
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately).
49 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, 120.00
Minimum anodic coating of grade AC 15)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading s
62 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal 17.25
size) in pavements, laid to required slope and camber in panels as required including consolidation
finishing and tamping complete.
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry
chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not
less than 4.50 kg and frame to be not less than
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast
lugs or dash fastener shall be paid for separately).
69 9.1.1 Second class teak wood 0.88
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory
windows fixing with butt hinges of required size with necessary screws, excluding panelling which
will be paid for separately, all complete as per direction of
76 10.20 Providing and fixing bolts including nuts and washers complete. 10.00
77 10.1 Structural steel work in single section, fixed with or without connecting p1ate,inc1uding 250.00
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours
and shades, laid on 20mm thick cement mortar
89 18.65 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm 4.00
with concealed fitting arrangements. Weighing not less than 106 gms.
205
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS
fittings& accessories etc. all complete, for
Abstract
Total of Sub Schedule - A1 (DSR-2021) 64,55,085.48
Total of Sub Schedule - A3 (NS Item) 64,310.40
Total A1 65,19,395.88
1142.80 1 Sqm 28,570.00 28,570.00
ng (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges,
64,55,085.48 64,55,085.48
DeptE .
IJNIT Cah St TO7AL n
Hismantelling)
870.14 l Hour 43,507.00 43,507.00
43,507.00 43,507.00
S Item) {For Bo*ewell}
309.97 1 6,199.40 6199.40
64,310.40 64,310.40
64,55,085.48 64,55,085 48
64,310.40 64,310.40
65,19,395.88 65,19,395.88
20% Deduction on DSR Rate -13,03,879.18
Total of DSR 2021 52,15,516.70
Total of Sub Schedule - A2 (USSR-2021) 43,507.00
Total Civil Engineering Cost 52,59,023.70
Contingency &1% 52,590.24
Total Cost 53,11,613.94
Sports Fund A0.l % 5,311.61
Departmental Charges B5.29% 2,80,984.38
Grand Total 55,97,909.93
-13,03,879.18
52,15,516.70
43,507.00
52,59,023.70
Sr.DEN/West/NED