SLAB
SLAB
SLAB
DESIGN OF SLAB
L&T CONSTRUCTION
WATER & EFFLUENT TREATEMENT IC
Slab ID : S4
Input data
Load calculation
Effective Depth ( Nominal Cover - dia of Bar/2) 140 140 140 140 mm
Min Ast ( 0.12 x 1000 x 175 / 100 ) 210 210 210 210 mm2
Diameter of bar 10 10 10 10 mm
Area of Steel Provided Ast (pro) 392.7 392.7 392.7 392.7 mm2
safe safe safe safe
Steel stress for Service Load, fs =0.58*fy*Ast (req) / Ast (pro) = 155.08 N/mm2
(l / d)max ( 1.98016437908497 x 26 ) = 51
= τv<τc
Hence shear reinf not required
L&T CONSTRUCTION
WATER & EFFLUENT TREATEMENT IC
DOCUMENT NO. DATE
PROJECT : RIGHT COMMAND OF LOWER SUKTEL IRRIGATION PROJECT LE22M794-C-LW-WS-3004 (PART-2) 14-Apr-24
DESIGNED CHECKED APPROVED
TITLE : Pump House 1 - Design Calculation
MSR SYAM PSP
2.1 SUMMARY OF SLAB DESIGN
Grade of Concrete fck = 25 N/mm2
Grade of Steel fy = 500 N/mm2
Clear Cover = 30 mm
Safe / Unsafe
Modification Factor
One way/ Two way
Pt, Provided
ULS Moment
Beam Width
Total Depth
Unfactored
Safe / Unsafe
Dia of Bar
Mom Co-eff
(l / d)actual
Slab Size
(Interior)
Live Load
Effective
(l / d)Basic
Factored
(l / d)max
Finishing
τc
τv
Ast Req
Vu
Nominal
Condition
Condition
Slab ID
fs
Ast Pro
Spacing
Self wt
Ly / Lx
Loading
Loading
Unsafe
Safe /
Ly (m)
Depth
Lx(m)
cover
Load
m m m m m mm mm mm kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kNm/m mm mm mm2 mm2 N/mm2 kN N/mm2 N/mm2
%
Ly/ Mx(-ve) 0 0.0 10 200 210 393 Safe
Lx<=2, Two Adjacent Mx(+ve) 0 0.0 10 200 210 393 Safe
S1 Pump house
Safe
Safe
3.120 2.540 0.3 3.26 2.68 0.82 TWO 4 Edges 175 30 140 4.375 1.2 1.5 7.08 10.61 0.281 155 1.98 26 51 23.25 17.27 0.12 0.38
floor My(-ve) 0.047 5.3 10 200 210 393 Safe
WAY Discontinuous
SLAB My(+ve) 0.035 3.9 10 200 210 393 Safe
Safe
Safe
3.800 4.7 0.3 3.93 4.84 1.23 TWO 2 Edge 175 30 140 4.375 1.2 1.5 7.08 10.61 0.281 155 1.98 26 51 28.11 20.88 0.15 0.38
floor My(-ve) 0.037 6.1 10 200 210 393 Safe
WAY Discontinuous
SLAB My(+ve) 0.028 4.6 10 200 210 393 Safe
Safe
Safe
3.800 4.7 0.3 3.93 4.84 1.23 TWO 1 175 30 140 4.375 1.2 1.5 7.08 10.61 0.281 155 1.98 26 51 28.11 20.88 0.15 0.38
floor panels My(-ve) 0.032 5.3 10 200 210 393 Safe
WAY
SLAB My(+ve) 0.024 3.9 10 200 210 393 Safe
Safe
Safe
Floor 2.200 2.675 0.3 2.34 2.81 1.20 TWO 1 175 30 140 4.375 1.2 21 26.58 39.86 0.281 155 1.98 26 51 16.68 46.54 0.33 0.38
panels My(-ve) 0.032 7.0 10 200 210 393 Safe
(with pedestal load) WAY
SLAB My(+ve) 0.024 5.2 10 200 210 393 Safe
Safe
Safe
1.925 4.7 0.3 2.06 4.84 2.35 1 End Span 175 30 140 4.375 1.2 10 15.58 23.36 0.281 155 1.98 26 51 14.71 24.06 0.17 0.38
Floor WAY My(-ve) 0 0.0 10 200 210 393 Safe
SLAB
My(+ve) 0 0.0 10 200 210 393 Safe
Safe
Safe
S6 PLC floor 2.925 4.35 0.3 3.04 4.46 1.47 TWO 4 Edges 150 30 116 3.750 1.2 5 9.95 14.92 0.217 241 1.64 26 43 26.18 22.66 0.20 0.34
WAY Discontinuous My(-ve) 0.047 6.5 8 200 180 251 Safe
SLAB My(+ve) 0.035 4.8 8 200 180 251 Safe
Safe
Safe
S7 PLC floor 2.525 3.78 0.3 2.64 3.89 1.48 TWO 3 150 30 116 3.750 1.2 5 9.95 14.92 0.217 208 1.86 26 48 22.73 19.68 0.17 0.34
Discontinuous My(-ve) 0.037 3.8 8 200 180 251 Safe
WAY
SLAB My(+ve) 0.028 2.9 8 200 180 251 Safe
Safe
Safe
S8 PLC floor 2.675 3.780 0.3 2.79 3.89 1.40 TWO 1 150 30 116 3.750 1.2 5 9.95 14.92 0.217 208 1.86 26 48 24.03 20.8 0.18 0.34
panels My(-ve) 0.032 3.7 8 200 180 251 Safe
WAY
SLAB My(+ve) 0.024 2.8 8 200 180 251 Safe
L&T CONSTRUCTION
WATER & EFFLUENT TREATEMENT IC
DOCUMENT NO. DATE
PROJECT : RIGHT COMMAND OF LOWER SUKTEL IRRIGATION PROJECT LE22M794-C-LW-WS-3004 (PART-2) 14-Apr-24
DESIGNED CHECKED APPROVED
TITLE : Pump House 1 - Design Calculation
MSR SYAM PSP
2.1 SUMMARY OF SLAB DESIGN
Grade of Concrete fck = 25 N/mm2
Grade of Steel fy = 500 N/mm2
Clear Cover = 30 mm
Safe / Unsafe
Modification Factor
One way/ Two way
Pt, Provided
ULS Moment
Beam Width
Total Depth
Unfactored
Safe / Unsafe
Dia of Bar
Mom Co-eff
(l / d)actual
Slab Size
(Interior)
Live Load
Effective
(l / d)Basic
Factored
(l / d)max
Finishing
τc
τv
Ast Req
Vu
Nominal
Condition
Condition
Slab ID
fs
Ast Pro
Spacing
Self wt
Ly / Lx
Loading
Loading
Unsafe
Safe /
Ly (m)
Depth
Lx(m)
cover
Load
m m m m m mm mm mm kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kNm/m mm mm mm2 mm2 N/mm2 kN N/mm2 N/mm2
%
Mx(-ve) 0.1 6.0 8 200 180 251 Safe
Ly/Lx>2,
S9 Electrical Room ONE Mx(+ve) 0.0833 5.0 8 200 180 251 Safe
Safe
Safe
1.900 6.725 0.3 2.01 6.84 3.40 1 End Span 150 30 116 3.750 1.2 5 9.95 14.92 0.217 208 1.86 26 48 17.34 15.01 0.13 0.34
floor WAY My(-ve) 0 0.0 8 200 180 251 Safe
SLAB
My(+ve) 0 0.0 8 200 180 251 Safe
Safe
Safe
1.900 4.700 0.3 2.01 4.81 2.39 2 Interior Span 150 30 116 3.750 1.2 5 9.95 14.92 0.217 208 1.86 26 48 17.34 15.01 0.13 0.34
floor WAY My(-ve) 0 0.0 8 200 180 251 Safe
SLAB
My(+ve) 0 0.0 8 200 180 251 Safe
Safe
Safe
1.000 2.000 0.3 1.11 2.11 1.90 TWO 6 Edges 150 30 116 3.750 1.2 5 9.95 14.92 0.217 208 1.86 26 48 9.586 8.298 0.07 0.34
floor My(-ve) 0.045 0.8 8 200 180 251 Safe
WAY Discontinuous
SLAB My(+ve) 0.035 0.6 8 200 180 251 Safe
Safe
Safe
S12 PLC room roof 2.850 3.780 0.3 2.94 3.87 1.32 TWO 3 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 32.27 14.15 0.16 0.38
Discontinuous My(-ve) 0.037 3.1 8 200 150 251 Safe
WAY
SLAB My(+ve) 0.028 2.3 8 200 150 251 Safe
Safe
Safe
S13 PLC room roof 2.525 3.780 0.3 2.61 3.87 1.48 TWO 1 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 28.7 12.59 0.14 0.38
panels My(-ve) 0.032 2.1 8 200 150 251 Safe
WAY
SLAB My(+ve) 0.024 1.6 8 200 150 251 Safe
Safe
Safe
S14 PLC room roof 2.675 3.780 0.3 2.76 3.87 1.40 TWO 4 Edges 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 30.35 13.31 0.15 0.38
WAY Discontinuous My(-ve) 0.047 3.5 8 200 150 251 Safe
SLAB My(+ve) 0.035 2.6 8 200 150 251 Safe
Safe
Safe
2.650 4.550 0.3 2.74 4.64 1.69 TWO 4 Edges 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 179 1.94 26 50 30.08 13.19 0.14 0.38
building roof
WAY Discontinuous My(-ve) 0.047 3.4 8 200 150 251 Safe
SLAB
My(+ve) 0.035 2.5 8 200 150 251 Safe
Safe
Safe
2.575 4.700 0.3 2.66 4.79 1.83 TWO 1 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 29.25 12.83 0.14 0.38
building roof panels
WAY My(-ve) 0.032 2.2 8 200 150 251 Safe
SLAB
My(+ve) 0.024 1.6 8 200 150 251 Safe
L&T CONSTRUCTION
WATER & EFFLUENT TREATEMENT IC
DOCUMENT NO. DATE
PROJECT : RIGHT COMMAND OF LOWER SUKTEL IRRIGATION PROJECT LE22M794-C-LW-WS-3004 (PART-2) 14-Apr-24
DESIGNED CHECKED APPROVED
TITLE : Pump House 1 - Design Calculation
MSR SYAM PSP
2.1 SUMMARY OF SLAB DESIGN
Grade of Concrete fck = 25 N/mm2
Grade of Steel fy = 500 N/mm2
Clear Cover = 30 mm
Safe / Unsafe
Modification Factor
One way/ Two way
Pt, Provided
ULS Moment
Beam Width
Total Depth
Unfactored
Safe / Unsafe
Dia of Bar
Mom Co-eff
(l / d)actual
Slab Size
(Interior)
Live Load
Effective
(l / d)Basic
Factored
(l / d)max
Finishing
τc
τv
Ast Req
Vu
Nominal
Condition
Condition
Slab ID
fs
Ast Pro
Spacing
Self wt
Ly / Lx
Loading
Loading
Unsafe
Safe /
Ly (m)
Depth
Lx(m)
cover
Load
m m m m m mm mm mm kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kNm/m mm mm mm2 mm2 N/mm2 kN N/mm2 N/mm2
%
Mx(-ve) 0.028 4.1 8 200 150 251 Safe
Ly/
Lx<=2, Mx(+ve) 0.028 4.1 8 200 150 251 Safe
S17 Electrical One Long Edge
Safe
Safe
3.800 4.700 0.3 3.89 4.79 1.24 TWO 3 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 42.71 18.73 0.21 0.38
building roof Discontinuous
WAY My(-ve) 0.037 5.4 8 200 150 251 Safe
SLAB
My(+ve) 0.028 4.1 8 200 150 251 Safe
Safe
Safe
building roof(OHT 2.820 3.060 0.3 2.91 3.15 1.08 TWO 8 Edge 125 30 90 3.125 9.3 7.05 19.48 29.21 0.582 218 1.30 26 34 32.28 42.43 0.47 0.52
load) WAY continuous My(-ve) 0.057 14.1 10 150 394 524 Safe
SLAB
My(+ve) 0.043 10.6 10 150 290 524 Safe
Safe
Safe
3.520 5.500 0.3 3.61 5.59 1.56 TWO 4 Edges 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 178 1.94 26 50 39.64 17.38 0.19 0.38
building roof
WAY Discontinuous My(-ve) 0.047 5.9 8 200 154 251 Safe
SLAB
My(+ve) 0.035 4.4 8 200 150 251 Safe
Safe
Safe
2.200 5.500 0.3 2.29 5.59 2.50 1 End Span 125 30 91 3.125 1.8 1.5 6.43 9.638 0.276 173 1.95 26 51 25.13 11.02 0.12 0.38
building roof WAY
My(-ve) 0 0.0 8 200 150 251 Safe
SLAB
My(+ve) 0 0.0 8 200 150 251 Safe