UK/IE
6 720 813 281 (2014/09)
Preface
Preface
Please read these instructions carefully
These instructions are applicable to the Worcester, Bosch
Group appliance model stated on the front cover only.
These instructions apply in the UK/IE only and must be followed
except for any statutory obligation.
After installation please leave this User instruction Manual,
Installation, Commissioning and Servicing Instructions and
completed Benchmark Checklist with the user.
Contents
2 General information 5
2.1 Energy efficiency 5 10 Environment / disposal 20
2.2 Servicing 5
2.3 Benchmark standard 5
2.4 User caution 5 11 Your guarantee 20
3 Controls 6 12 Glossary 21
3.1 Operating the boiler 8
3.1.1 Boiler display 8
3.1.2 Setting the boiler flow temperature for the
system 8
3.1.3 Turning the central heating off during the
summer 8
3.1.4 Boiler frost protection 9
3.1.5 No Integral diverter valve fitted: Cylinder
temperature adjustment 9
3.1.6 Optional integral diverter valve kit fitted:
Setting the cylinder hot water temperature. 9
3.1.7 Domestic hot water eco and preheat modes
10
3.1.8 Domestic hot water: switching between Eco
and Preheat modes 10
3.1.9 Turn off the Operation/fault diagnostic light
(blue) 10
4 System Pressure 11
4.1 Sealed heating systems 11
4.2 External filling loop 12
5 Service Clearances 13
7 Fault Finding 15
7.1 Boiler alert state 16
7.2 Boiler reset 16
7.3 Extreme cold weather 17
3 Controls
▶ To gain access to the boiler controls pull the flap down using the curved flap handle.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
o
1W
2.
8 -0
3 35
64
20
67
Display symbols
SCREEN DISPLAY BRIEF DESCRIPTION EXPLANATION
All possible screen symbols This screen is displayed briefly during boiler start
up and shows all the symbols that could be
displayed on the screen.
°C
°F
eco
2
°C 1 3
reset ok
°F 0 bar 4
°C
6720807727-01.1Wo
min max min max
°F
3.
eco
2
°C 1 3
reset ok
°F 0 bar 4
Eco
e
°C
°F
min max min max
Eco 1.
2. 6720643358-03.1Wo
▶ Comfort levels within rooms should be controlled by your thermostatic radiator valves and/or room thermostat.
NOTICE: The boiler must be switched on with a gas supply in order for the built -in auto frost protection to work as
described.
If you are leaving your property unoccupied during cold weather, please leave your programmer on constant and your room
thermostat set to 15°C.
▶ If the temperature within the boiler falls below 8°C the pump will run to circulate water and prevent the system freezing.
– If the temperature does not rise to 9°C within 30 minutes of the pump operating, the boiler will fire up to provide heat to
bring the temperature up.
▶ If the temperature within the boiler falls below 5°C the boiler will fire immediately, bringing the boiler temperature up to 15°C
to avoid the possibility of the system freezing.
▶ This process will be repeated until such time that the boiler temperature does not drop below 5°C.
3.1.6 Optional integral diverter valve kit fitted: Setting the cylinder hot water temperature.
An internal or external timer/programmer coupled with the optional integral diverter valve kit with cylinder
temperature sensor is required to be able to set the hot water temperature.
If an FR110, FW100 and Sense II controller is also fitted, in conjunction with the diverter valve, they assume control
over the delivered temperatures, reducing the effect of the temperature controls. Set both to maximum.
1. Turn the hot water temperature control knob to the desired level between 40 and 70°C, this will be shown on the digital display.
eco
2
°C 1 3
reset ok
°F 0 bar 4
e
°C
°F
min max min max
1.
6720807727-03.1Wo
1 1
°C °C
6720813281-01.1Wo
2 °F 3 °F
Eco PreHeat
3.1.8 Domestic hot water: switching between Eco and Preheat modes
1. Press and hold the Eco button ok for at least four seconds to enter the energy saving Eco mode, when Eco mode is active,
“Eco” will be displayed.
To exit Eco mode and return to PreHeat
2. Press and hold the Eco button ok for at least four seconds and “PreHeat” will be displayed.
°C
eco
°F reset
°C
ok
1
2
3
°F
Eco
0 bar 4
1.
Eco
e
°C
°F
PreHeat
6720813281-02.1Wo
4 System Pressure
4.1 Sealed heating systems
This appliance is fitted to a sealed heating system which is pre-pressurised. Your installer will advise you of the minimum and
maximum pressure indicated on the pressure gauge.
▶ Check regularly that the pressure is maintained.
▶ If the pressure gauge reads less than 1 bar then the system requires re-charging.
▶ Contact your installer or maintenance engineer if a permanent significant decrease or increase in pressure is indicated on the
pressure gauge.
1.5 bar
Max
A 2
1 bar
6720643356-11.1Wo
1 3
Min
0 bar 4
NOTICE: To comply with the Water Authority regulations you must remove the “filling key” or disconnect the
external filling loop after re-pressurisation.
Once the external filling loop has been located, follow the instructions for re-pressurising the system.
1. Unscrew blanking cap.
2. Attach the hose to the valves, screw on hand-tight.
3. Turn the handle/screwdriver slot through 90° to open the valves.
4. The handle/screwdriver slot will be in-line with the valves
4. 4.
1. 2. 3. 3.
6. 6.
1.5 bar
Max
A 2
1 bar
1 3 5. 5. 7.
Min
6720806947-01.1Wo
0 bar 4
If the pressure gauge reads more than 1.5 bar as a result of over filling, bleed one radiator until the pressure gauge
returns to between 1 and 1.5 bar.
5 Service Clearances
Your installer will have provided adequate space around the boiler for safety and servicing access.
880mm
20mm* 170/210mm***
1060/1100mm***
600mm**
5mm
5mm
6720646608-122.1Wo
200mm
400mm 300mm
Fig. 6 Service clearances
[*] Minimum clearances to removable door
[**] Minimum clearances required for servicing
[***] Height for either 60/100 flue or 80/125 flue
7 Fault Finding
In the event that the appliance stops functioning or does not perform as expected, please see table below These problems are some
of the most common causes. Should the problem persist or if other fault codes are displayed, then it will be necessary to contact
Worcester, Bosch Group.
This table gives information on basic operating system problems.
eco
2
°C 1 3
reset ok
°F 0 bar 4
227
e
°C
6720643358-14.1Wo
min max min max
°F
227
eco
2
°C 1 3
reset ok
°F 0 bar 4
1.
Reset
e
°C
°F
min max min max
Reset 2.
6720643358-09.2Wo
Due to the internal safety systems of your Greenstar CDi Compact boiler, some codes cannot be cleared by a simple reset. Please
contact Worcester, Bosch Group for further assistance.
When calling Worcester, Bosch Group about a fault, it will be useful to quote the alert code and three digit number under the alert
code, e.g. EA and 227. If there is a fault that cannot be reset by you, the user, then a service engineer visit will be necessary.
8 Fault or Breakdown
This boiler is supported in the UK and Eire by Worcester, Bosch Group.
Specialist Service Engineers are available to attend a breakdown occurring on this boiler.
Invoices for attendance and repair work carried out on this boiler by any third party will not be accepted.
Technical Support
In the event of a boiler fault or breakdown please contact Worcester, Bosch Group appointments team on 0330 123 9339.
Your advisor will arrange for an engineer to call with the minimum of delay; under normal circumstances this will be from 1 - 3
working days (excluding weekends) for priority breakdown situations (no hot water and/or heating).
Room thermostats
Reducing the setting of the room thermostat by 1°C can reduce fuel consumption by up to 10%.
Roof insulation
Around 30% of the heat loss from a property is through the roof. Replace any old insulation with new insulation, preferably of around
200mm thickness or more.
Window frames
Single glazed windows, particularly those with steel frames, can lose a great deal of heat. Consideration should be given to
replacement with PVCu or wooden framed double glazed units.
Radiators
If a radiator is sited underneath a window, its performance will be affected if the curtains are allowed to drape over the radiator.
Shelves fitted above or in front of the radiator should also be avoided.
It is advisable to manually adjust all thermostatic radiator valves every 2 - 3 months to prevent them sticking. Ensure radiator valves
are correctly set and not damaged.
Draughts
Try to ensure that draughts around doors, windows, letter boxes and keyholes etc. are reduced by using a suitable draught excluder.
Curtains
Lined curtains, or heavier full length curtains can provide excellent insulation. However, always ensure that the curtains do not
drape over radiators.
10 Environment / disposal
Environmental protection is a fundamental corporate strategy of the Bosch Group.
The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental
protection legislation and regulations are strictly observed.
We use the best possible technology and materials for protecting the environment taking account of economic considerations.
Packaging
We participate in the recycling programmes of the countries in which our products are sold to ensure optimum recycling.
All of our packaging materials are environmentally compatible and can be recycled.
USED APPLIANCES
▶ All Greenstar gas boilers are 100% recycleable.
The various assemblies can be easily dismantled and synthetic materials are marked accordingly. Assemblies
can therefore be sorted by composition and passed on for recycling.
11 Your guarantee
This boiler has a guarantee against faulty materials or workmanship for a period from the date of installation subject to the following
terms and conditions:
• During the period of this guarantee any components of the boiler which are proven to be faulty or defective in manufacture will
be exchanged or repaired free of charge by Bosch Thermotechnology Ltd.
• The householder may be asked to prove the date of installation, that the boiler was correctly commissioned and, where
appropriate, the first year's service has been carried out to the satisfaction of Bosch Thermotechnology Ltd., when requested.
These should be documented as a part of the Benchmark Checklist.
• The boiler has been used only for the normal domestic purposes for which it was designed.
This guarantee does not affect your statutory rights.
Guarantee registration
Your Greenstar boiler carries a guarantee against faulty material or manufacturer subject to Terms and Conditions.
To read the full Terms & Conditions please visit us on-line at www.worcester-bosch.co.uk/guarantee. The Guarantee Registration
form is available on this same page and can be completed and submitted electronically.
Alternatively, please telephone one of our Guarantee Registration advisors on 0330 123 2552.
Your statutory rights are not affected by the manufacturers guarantee.
Model
Serial No.1)
Type/size
Date of installation
Name of Installer
Telephone number of Installer
Table 3
1) See boiler identification label on boiler fascia or Benchmark Checklist in the back of the Installation, Commissioning & Servicing
Instructions.
12 Glossary
Central heating systems
All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be bled
by releasing air through the bleed screw at the top of the radiator.
Ask your installer to show you how this is done.
This boiler is fitted to a sealed system. Should water leaks be found or if excessive bleeding is required, then a service engineer must
be contacted to inspect the installation and rectify any fault.
Only additives that are compatible with aluminium may be used in the system. Any incompatible additive used will invalidate the
guarantee.
Pluming and condensate drain
This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This is quite normal.
The boiler produces condensate which is discharged regularly by a syphon within the boiler via a plastic pipe to a drain. This pipe
must not be blocked or altered in any way.
Room thermostat / programmer
A room thermostat / programmer must be fitted to control the central heating. This controls the times and temperatures of the
central heating, preventing the boiler from firing unnecessarily. Refer to the instructions supplied with the thermostat and
programmer for further information.
Thermostatic radiator valves
Thermostatic radiator valves must be fitted in sleeping accommodation. It is recommended that this type of valve is fitted to all but
one of the radiators. The remaining radiator, where the room thermostat is located, must be uncontrolled and left open.
Pump over run function
After the boiler has finished a demand for central heating or hot water, the pump may continue to run for a short while to dissipate
the heat from within the boiler.
Pump anti-seizure
If there has been no heating demand for 24 hours, the boiler will run the system pump for a few seconds to reduce the possibility of
pump seizure during long periods of inactivity.