-
MiniCACTUS: A 65 ps Time Resolution Depleted Monolithic CMOS Sensor
Authors:
Yavuz Degerli,
Fabrice Guilloux,
Tomasz Hemperek,
Jean-Pierre Meyer,
Philippe Schwemling
Abstract:
MiniCACTUS is a monolithic sensor prototype optimised for timing measurement of charged particles. It has been designed in a standard 150 nm CMOS process without dedicated amplification layer. It is intended as a demonstrator chip for future large scale timing detectors, like upgrades of timing detectors at LHC, or future high energy physics detector projects. The sensor features an active array o…
▽ More
MiniCACTUS is a monolithic sensor prototype optimised for timing measurement of charged particles. It has been designed in a standard 150 nm CMOS process without dedicated amplification layer. It is intended as a demonstrator chip for future large scale timing detectors, like upgrades of timing detectors at LHC, or future high energy physics detector projects. The sensor features an active array of 2 x 4 diodes, analog and digital Front-Ends (FEs), a slow control interface, and bias circuitry programmable through internal DACs. The sensing element is a deep n-well/p-substrate diode. Thanks to the optimized guard-rings surrounding the whole chip, it is possible to apply safely more than 450 V on the high-resistivity substrate allowing fast charge collection. The baseline pixel dimensions are 1.0 mm x 1.0 mm and 0.5 mm x 1.0 mm. The analog FEs and the discriminators for each pixel are implemented outside the pixel, at the column level. The power consumption is approximately 300 mW/cm$\mathbf {^2}$, which is compatible with cooling infrastructure available at LHC experiments, and making integration of this concept viable in future high energy physics experiments. After fabrication, the sensors have been thinned to 100 $μ$m, 200 $μ$m and 300 $μ$m total thickness and then post-processed for backside biasing. The time resolution of several sensors with different thicknesses has been measured in 3 test-beam campaigns using high energy muons (Minimum Ionizing Particles) at CERN SPS in 2021 and 2022. A resolution of 65.3 ps has been measured with on-chip FE and discriminator. This paper will focus on the results of these test-beam campaigns.
△ Less
Submitted 15 September, 2023;
originally announced September 2023.
-
The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters
Authors:
G. Aad,
A. V. Akimov,
K. Al Khoury,
M. Aleksa,
T. Andeen,
C. Anelli,
N. Aranzabal,
C. Armijo,
A. Bagulia,
J. Ban,
T. Barillari,
F. Bellachia,
M. Benoit,
F. Bernon,
A. Berthold,
H. Bervas,
D. Besin,
A. Betti,
Y. Bianga,
M. Biaut,
D. Boline,
J. Boudreau,
T. Bouedo,
N. Braam,
M. Cano Bret
, et al. (173 additional authors not shown)
Abstract:
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Cons…
▽ More
The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. This paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.
△ Less
Submitted 16 May, 2022; v1 submitted 15 February, 2022;
originally announced February 2022.
-
DMAPS Monopix developments in large and small electrode designs
Authors:
Christian Bespin,
Marlon Barbero,
Pierre Barrillon,
Ivan Berdalovic,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Roberto Cardella,
Zongde Chen,
Yavuz Degerli,
Jochen Dingfelder,
Leyre Flores Sanz de Acedo,
Stephanie Godiot,
Fabrice Guilloux,
Toko Hirono,
Tomasz Hemperek,
Fabian Hügging,
Hans Krüger,
Thanushan Kugathasan,
Cesar Augusto Marin Tobon,
Konstantinos Moustakas,
Patrick Pangaud,
Heinz Pernegger,
Francesco Piro,
Petra Riedler
, et al. (8 additional authors not shown)
Abstract:
LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows…
▽ More
LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows a design with large charge collection electrode where readout electronics are placed inside. Generally, this offers a homogeneous electrical field in the sensor and short drift distances. TJ-Monopix1 employs a small charge collection electrode with readout electronics separated from the electrode and an additional n-type implant to achieve full depletion of the sensitive volume. This approach offers a low sensor capacitance and therefore low noise and is typically implemented with small pixel size. Both detectors have been characterized before and after irradiation using lab tests and particle beams.
△ Less
Submitted 9 July, 2020; v1 submitted 3 June, 2020;
originally announced June 2020.
-
CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology
Authors:
Yavuz Degerli,
Fabrice Guilloux,
Claude Guyot,
Jean-Pierre Meyer,
Ahmimed Ouraou,
Philippe Schwemling,
Artur Apresyan,
Ryan E. Heller,
Mohd Meraj,
Christian Pena,
Si Xie,
Tomasz Hemperek
Abstract:
The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will…
▽ More
The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.
△ Less
Submitted 6 May, 2020; v1 submitted 9 March, 2020;
originally announced March 2020.
-
Radiation hard DMAPS pixel sensors in 150nm CMOS technology for operation at LHC
Authors:
M. Barbero,
P. Barrillon,
C. Bespin,
S. Bhat,
P. Breugnon,
I. Caicedo,
Z. Chen,
Y. Degerli,
J. Dingfelder,
S. Godiot,
F. Guilloux,
T. Hemperek,
T. Hirono,
F. Hügging,
H. Krüger,
K. Moustakas,
A. Ouraou,
P. Pangaud,
I. Peric,
D-L. Pohl,
P. Rymaszewski,
P. Schwemling,
M. Vandenbroucke,
T. Wang,
N. Wermes
Abstract:
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s employing silicon substrate with a thin epitaxial layer in which deposited charge is collected by disordered diffusion rather than by drift in an electric field. As a consequence the signal is small and slow, and the radiation tolerance is below the requirements for LHC experiments by factors of 100 to 1000. We develop…
▽ More
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s employing silicon substrate with a thin epitaxial layer in which deposited charge is collected by disordered diffusion rather than by drift in an electric field. As a consequence the signal is small and slow, and the radiation tolerance is below the requirements for LHC experiments by factors of 100 to 1000. We developed fully depleted (D)MAPS pixel sensors employing a 150 nm CMOS technology and using a high resistivity substrate as well as a high biasing voltage. The development has been carried out in three subsequent iterations, from prototypes to a large pixel matrix comprising a complete readout architecture suitable for LHC operation. Full CMOS electronics is embedded in large deep n-wells which at the same time serve as collection nodes (large electrode design). The devices have been intensively characterized before and after irradiation employing lab tests as well as particle beams. The devices can cope with particle rates seen by the innermost pixel detectors of the LHC pp-experiments or as seen by the outer pixel layers of the planned HL-LHC upgrade. They are radiation hard to particle fluences of at least $10^{15}~\mathrm{n_{eq}/cm^2}$ and total ionization doses of at least 50 Mrad.
△ Less
Submitted 25 May, 2020; v1 submitted 4 November, 2019;
originally announced November 2019.
-
Timing Performance of a Micro-Channel-Plate Photomultiplier Tube
Authors:
Jonathan Bortfeldt,
Florian Brunbauer,
Claude David,
Daniel Desforge,
Georgios Fanourakis,
Michele Gallinaro,
Francisco Garcia,
Ioannis Giomataris,
Thomas Gustavsson,
Claude Guyot,
Francisco Jose Iguaz,
Mariam Kebbiri,
Kostas Kordas,
Philippe Legou,
Jianbei Liu,
Michael Lupberger,
Ioannis Manthos,
Hans Müller,
Vasileios Niaouris,
Eraldo Oliveri,
Thomas Papaevangelou,
Konstantinos Paraschou,
Michal Pomorski,
Filippo Resnati,
Leszek Ropelewski
, et al. (14 additional authors not shown)
Abstract:
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the tw…
▽ More
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.
△ Less
Submitted 14 February, 2020; v1 submitted 27 September, 2019;
originally announced September 2019.
-
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
Authors:
M. Dyndal,
V. Dao,
P. Allport,
I. Asensi Tortajada,
M. Barbero,
S. Bhat,
D. Bortoletto,
I. Berdalovic,
C. Bespin,
C. Buttar,
I. Caicedo,
R. Cardella,
F. Dachs,
Y. Degerli,
H. Denizli,
L. Flores Sanz de Acedo,
P. Freeman,
L. Gonella,
A. Habib,
T. Hemperek,
T. Hirono,
B. Hiti,
T. Kugathasan,
I. Mandić,
D. Maneuski
, et al. (19 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silico…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.
△ Less
Submitted 14 December, 2019; v1 submitted 26 September, 2019;
originally announced September 2019.
-
The Monopix chips: Depleted monolithic active pixel sensors with a column-drain read-out architecture for the ATLAS Inner Tracker upgrade
Authors:
Ivan Caicedo,
Marlon Barbero,
Pierre Barrillon,
Ivan Berdalovic,
Siddharth Bhat,
Christian Bespin,
Patrick Breugnon,
Roberto Cardella,
Zongde Chen,
Yavuz Degerli,
Jochen Dingfelder,
Stephanie Godiot,
Fabrice Guilloux,
Toko Hirono,
Tomasz Hemperek,
Fabian Hügging,
Hans Krüger,
Thanushan Kugathasan,
Konstantinos Moustakas,
Patrick Pangaud,
Heinz Pernegger,
David-Leon Pohl,
Petra Riedler,
Alexandre Rozanov,
Piotr Rymaszewski
, et al. (5 additional authors not shown)
Abstract:
Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 150nm CMOS process on a highly resistive substrate (>…
▽ More
Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 150nm CMOS process on a highly resistive substrate (>2 k$Ω\,$cm), while TJ-Monopix was fabricated using a modified 180 nm CMOS process with a 1 k$Ω\,$cm epi-layer for depletion. The chips differ in their front-end design, biasing scheme, pixel pitch, dimensions of the collecting electrode relative to the pixel size (large and small electrode design, respectively) and the placement of read-out electronics within such electrode. Both chips were operational after thinning down to 100 $\mathrmμ$m and additional back-side processing in LF-Monopix for total bulk depletion. The results in this work include measurements of their leakage current, noise, threshold dispersion, response to minimum ionizing particles and efficiency in test beam campaigns. In addition, the outcome from measurements after irradiation with neutrons up to a dose of $1\times10^{15}\,\mathrm{n_{eq} / cm}^{2}$ and its implications for future designs are discussed.
△ Less
Submitted 25 April, 2019; v1 submitted 10 February, 2019;
originally announced February 2019.
-
Precise Charged Particle Timing with the PICOSEC Detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
C. Guyot,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained wit…
▽ More
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained with this new detector yield a time resolution of 24\,ps for 150\,GeV muons and 76\,ps for single photoelectrons. In this paper we will report on the performance of the PICOSEC in test beams, as well as simulation studies and modelling of its timing characteristics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
Design and Evaluation of LAr Trigger Digitizer Board in the ATLAS Phase-I Upgrade
Authors:
Kai Chen,
Hucheng Chen,
Mauro Citterio,
Herve Deschamps,
Aude Grabas,
Stefano Latorre,
Massimo Lazzaroni,
Hongbin Liu,
Phillippe Schwemling,
Stefan Simion,
Hao Xu,
Heling Zhu
Abstract:
The LHC upgrade is planned to enhance the instantaneous luminosity during Run 3 from 2021 through 2023. The Phase-I upgrade of the trigger readout electronics for the ATLAS Liquid Argon (LAr) Calorimeters will be installed during the second long shutdown of LHC in 2019-2020. In this upgrade, the so-called super cells are introduced to provide higher granularity, higher resolution and longitudinal…
▽ More
The LHC upgrade is planned to enhance the instantaneous luminosity during Run 3 from 2021 through 2023. The Phase-I upgrade of the trigger readout electronics for the ATLAS Liquid Argon (LAr) Calorimeters will be installed during the second long shutdown of LHC in 2019-2020. In this upgrade, the so-called super cells are introduced to provide higher granularity, higher resolution and longitudinal shower shape information from the LAr calorimeters to the level-1 trigger processors. A new LAr Trigger Digitizer Board (LTDB) will manipulate and digitize 320 channels of super cell signals, and transmit it via 40 fiber optical links to the back end where data are further processed and transmitted to the trigger processors. Five pairs of bidirectional GBT links are used for slow control from the Front-end LInks eXchange (FELIX) in the ATLAS TDAQ system. LTDB also outputs 64 summed analog signals to the current Tower Builder Board via the new baseplane. A test system is developed to test all functions of the LTDB and carry out the performance measurement. A back end PCIe card is designed which has the circuit to interface to the ATLAS trigger, time and control system. It can control the generation of injection signals to the LTDB for performance test. It also configures and calibrate all ASICs on the LTDB.
△ Less
Submitted 22 June, 2018; v1 submitted 20 June, 2018;
originally announced June 2018.
-
Characterization of a depleted monolithic pixel sensors in 150 nm CMOS technology for the ATLAS Inner Tracker upgrade
Authors:
F. J. Iguaz,
F. Balli,
M. Barbero,
S. Bhat,
P. Breugnon,
I. Caicedo,
Z. Chen,
Y. Degerli,
S. Godiot,
F. Guilloux,
C. Guyot,
T. Hemperek,
T. Hirono,
H. Krüger,
J. P. Meyer,
A. Ouraou,
P. Pangaud,
P. Rymaszewski,
P. Schwemling,
M. Vandenbroucke,
T. Wang,
N. Wermes
Abstract:
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150\,nm CMOS process. DMAPS exploit high voltage and/or high resistivity inclusion of modern CMOS technologies to achieve substantial depletion in the sensing volume. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating…
▽ More
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150\,nm CMOS process. DMAPS exploit high voltage and/or high resistivity inclusion of modern CMOS technologies to achieve substantial depletion in the sensing volume. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade in 2025 for the High Luminosity Large Hadron Collider (HL-LHC). This type of devices has a lower production cost and lower material budget compared to presently used hybrid designs. In this work, the chip architecture will be described followed by the characterization of the different pre-amplifier and discriminator flavors with an external injection signal and an iron source (5.9\,keV x-rays).
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept
Authors:
F. J. Iguaz,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
F. García,
I. Giomataris,
D. González-Díaz,
T. Gustavsson,
C. Guyot,
M. Kebbiri,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at…
▽ More
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk, resistive, multipad) and photocathodes (metallic+CsI, pure metallic, diamond). Finally, the prospects for building a demonstrator based on PICOSEC detection concept for future experiments will be discussed. In particular, the scaling strategies for a large area coverage with a multichannel readout plane, the R\&D on solid converters for building a robust photocathode and the different resistive configurations for a robust readout.
△ Less
Submitted 4 August, 2018; v1 submitted 12 June, 2018;
originally announced June 2018.
-
Depleted Fully Monolithic Active CMOS Pixel Sensors (DMAPS) in High Resistivity 150~nm Technology for LHC
Authors:
Toko Hirono,
Marlon Barbero,
Pierre Barrillon,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Zongde Chen,
Michael Daas,
Yavuz Degerli,
Fabrice Guilloux,
Tomasz Hemperek,
Fabian Hugging,
Hans Kruger,
Patrick Pangaud,
Piotr Rymaszewski,
Philippe Schwemling,
Maxence Vandenbroucke,
Tianyang Wang,
Norbert Wermes
Abstract:
Depleted monolithic CMOS active pixel sensors (DMAPS) have been developed in order to demonstrate their suitability as pixel detectors in the outer layers of a toroidal LHC apparatus inner tracker (ATLAS ITk) pixel detector in the high-luminosity large hadron collider (HL-LHC). Two prototypes have been fabricated using 150 nm CMOS technology on high resistivity (> 2 k$Ω$ $cm^2$) wafers. The chip s…
▽ More
Depleted monolithic CMOS active pixel sensors (DMAPS) have been developed in order to demonstrate their suitability as pixel detectors in the outer layers of a toroidal LHC apparatus inner tracker (ATLAS ITk) pixel detector in the high-luminosity large hadron collider (HL-LHC). Two prototypes have been fabricated using 150 nm CMOS technology on high resistivity (> 2 k$Ω$ $cm^2$) wafers. The chip size is equivalent to that of the current ATLAS pixel detector readout chip. One of the prototypes is used for detailed characterization of the sensor and the analog readout of the DMAPS. The other is a fully monolithic DMAPS including fast readout digital logic that handles the required hit rate. In order to yield a strong homogeneous electric field within the sensor volume, thinning of the wafer was tested. The prototypes were irradiated with X-ray up to a total ionization dose (TID) of 50 Mrad and with neutrons up to non-ionizing energy loss (NIEL) of $10^{15}$ $n_{eq}/cm^2$. The analog readout circuitry maintained its performance after TID irradiation, and the hit-efficiency at > $10^7$ noise occupancy was as high as 98.9 % after NIEL irradiation.
△ Less
Submitted 25 March, 2018;
originally announced March 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
I. Giomataris,
D. González-Díaz,
T. Gustavsson,
C. Guyot,
F. J. Iguaz,
M. Kebbiri,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski,
B. Qi
, et al. (15 additional authors not shown)
Abstract:
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to…
▽ More
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. First results obtained with this new detector yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single photoelectrons.
△ Less
Submitted 14 March, 2018; v1 submitted 14 December, 2017;
originally announced December 2017.
-
Development of depleted monolithic pixel sensors in 150 nm CMOS technology for the ATLAS Inner Tracker upgrade
Authors:
Piotr Rymaszewski,
Marlon Barbero,
Siddharth Bhat,
Patrick Breugnon,
Ivan Caicedo,
Zongde Chen,
Yavuz Degerli,
Stephanie Godiot,
Fabrice Guilloux,
Claude Guyot,
Tomasz Hemperek,
Toko Hirono,
Fabian Hügging,
Hans Krüger,
Mohamed Lachkar,
Patrick Pangaud,
Alexandre Rozanov,
Philippe Schwemling,
Maxence Vandenbroucke,
Tianyang Wang,
Norbert Wermes
Abstract:
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150 nm CMOS process. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade for the High Luminosity Large Hadron Collider (HL-LHC). Implementing such a…
▽ More
This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150 nm CMOS process. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade for the High Luminosity Large Hadron Collider (HL-LHC). Implementing such a device in the detector module will result in a lower production cost and lower material budget compared to the presently used hybrid designs. In this paper the chip architecture will be described followed by the simulation and measurement results.
△ Less
Submitted 15 November, 2017; v1 submitted 3 November, 2017;
originally announced November 2017.
-
Depleted fully monolithic CMOS pixel detectors using a column based readout architecture for the ATLAS Inner Tracker upgrade
Authors:
T. Wang,
M. Barbero,
I. Berdalovic,
C. Bespin,
S. Bhat,
P. Breugnon,
I. Caicedo,
R. Cardella,
Z. Chen,
Y. Degerli,
N. Egidos,
S. Godiot,
F. Guilloux,
T. Hemperek,
T. Hirono,
H. Krüger,
T. Kugathasan,
F. Hügging,
C. A. Marin Tobon,
K. Moustakas,
P. Pangaud,
P. Schwemling,
H. Pernegger,
D-L. Pohl,
A. Rozanov
, et al. (3 additional authors not shown)
Abstract:
Depleted monolithic active pixel sensors (DMAPS), which exploit high voltage and/or high resistivity add-ons of modern CMOS technologies to achieve substantial depletion in the sensing volume, have proven to have high radiation tolerance towards the requirements of ATLAS in the high-luminosity LHC era. Depleted fully monolithic CMOS pixels with fast readout architectures are currently being develo…
▽ More
Depleted monolithic active pixel sensors (DMAPS), which exploit high voltage and/or high resistivity add-ons of modern CMOS technologies to achieve substantial depletion in the sensing volume, have proven to have high radiation tolerance towards the requirements of ATLAS in the high-luminosity LHC era. Depleted fully monolithic CMOS pixels with fast readout architectures are currently being developed as promising candidates for the outer pixel layers of the future ATLAS Inner Tracker, which will be installed during the phase II upgrade of ATLAS around year 2025. In this work, two DMAPS prototype designs, named LF-MonoPix and TJ-MonoPix, are presented. LF-MonoPix was designed and fabricated in the LFoundry 150~nm CMOS technology, and TJ-MonoPix has been designed in the TowerJazz 180~nm CMOS technology. Both chips employ the same readout architecture, i.e. the column drain architecture, whereas different sensor implementation concepts are pursued. The design of the two prototypes will be described. First measurement results for LF-MonoPix will also be shown.
△ Less
Submitted 29 September, 2017;
originally announced October 2017.
-
A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
Authors:
E. Abat,
J. M. Abdallah,
T. N. Addy,
P. Adragna,
M. Aharrouche,
A. Ahmad,
T. P. A. Akesson,
M. Aleksa,
C. Alexa,
K. Anderson,
A. Andreazza,
F. Anghinolfi,
A. Antonaki,
G. Arabidze,
E. Arik,
T. Atkinson,
J. Baines,
O. K. Baker,
D. Banfi,
S. Baron,
A. J. Barr,
R. Beccherle,
H. P. Beck,
B. Belhorma,
P. J. Bell
, et al. (460 additional authors not shown)
Abstract:
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in…
▽ More
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
△ Less
Submitted 12 May, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter
Authors:
M. Aharrouche,
J. Colas,
L. Di Ciaccio,
M. El Kacimi,
O. Gaumer,
M. Gouanere,
D. Goujdami,
R. Lafaye,
S. Laplace,
C. Le Maner,
L. Neukermans,
P. Perrodo,
L. Poggioli,
D. Prieur,
H. Przysiezniak,
G. Sauvage,
I. Wingerter-Seez,
R. Zitoun,
F. Lanni,
L. Lu,
H. Ma,
S. Rajago palan,
H. Takai,
A. Belymam,
D. Benchekroun
, et al. (77 additional authors not shown)
Abstract:
The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction cha…
▽ More
The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.
△ Less
Submitted 7 September, 2007;
originally announced September 2007.