Design Calculation Tank
Design Calculation Tank
Wind Load
Seismic Zone Factor Z(Zone-2B)
Joint Efficiency
Material For Shell
Job No.:
Rev 0
Gujarat (Dahej)
API-650
6.000 m
8.000 m
8.000 m
1529.530 kg/m^2
509.845 kg/m^2
9.5639 m
75 deg. C
= 19.69 ft
= 26.25 ft
= 26.25 ft
149.894 mbar (g)
49.965 mbar (g)
= 31.38 ft
= 167 F
45 deg. C
Full of Liquid
0.978
O-touline
3
3
0
1.5
47.00 m/sec
0.16
0.85
Yield Value
Page No.:
mm for Bottom
mm for Shell course
mm roof structure either side
mm for Roof
IS 875 : Part III
IS 1893 :Part I
for shell only
IS 2062 Gr B
250.00 MPa Tensile Value 410.00 MPa
IS 2062 Gr B
250.00 MPa Tensile Value 410.00 MPa
IS 2062 Gr B
250.00 MPa Tensile Value 410.00 MPa
20.0 m^3/hr
20.0 m^3/hr
225.0 m^3
Cone Roof
Design Of Shell
Multiplication Factor ( M ) =
1.000
164.00 MPa
Sd=
164.00 MPa
175.71 MPa
Design Thickness :
td =
td =
td =
4.9 x D x ( H - 0.3 ) x G / ( Sd x E ) + CA
4.9 x 6 x ( 9.564 - 0.3 ) x 0.978 / ( 164 x 0.85) + 3
4.91 mm
Test Thickness :
tt =
tt =
tt =
5 mm
Course
from
Bottom
Height of
course in
mm
1
2
3
4
5
6
7
8
9
10
11
12
1500
1500
1500
1500
1500
500
0
0
0
0
0
Head incl.
Internal
pressure in
mm
9563.9
8063.9
6563.9
5063.9
3563.9
2063.9
1563.9
1563.9
1563.9
1563.9
1563.9
1563.9
Head incl.
td incl.
Internal pressure
CA
in m
9.56
8.06
6.56
5.06
3.56
2.06
1.56
1.56
1.56
1.56
1.56
1.56
4.91
4.60
4.29
3.98
3.67
3.36
3.26
3.26
3.26
3.26
3.26
3.26
tt
1.82
1.53
1.23
0.94
0.64
0.35
0.25
0.25
0.25
0.25
0.25
0.25
higher of
t
td & tt provided
4.91
4.60
4.29
3.98
3.67
3.36
3.26
3.26
3.26
3.26
3.26
3.26
10.00
10.00
8.00
8.00
8.00
8.00
0.00
0.00
0.00
0.00
0.00
Material
IS 2062 Gr B
IS 2062 Gr B
IS 2062 Gr B
IS 2062 Gr B
IS 2062 Gr B
IS 2062 Gr B
8000
Provide Curb Angle
area
Weight/mtr
80 x
1216
9.4848
80 x
mm^2
Kg
47.0 m/s
1.07
1.05
1.00
1.15
Vbx k1 x k2 x k3x k4
47 x 1.07 x 1.05 x 1 x 1.15
60.7 m/s
225.54 kg/m^2
218.61 km/hr
Clause 5.3.1
Clause 5.3.2.2
Clause 5.3.3
Clause 5.3.4
60.7 m/s
136.63 miles/hr
47.00 m/s
Ce x Cq x qs x Iw
1.43
( Table 16G ) Exposure C
0.8
( Table 16H ) Tanks
1.0
(As per specification) ( Table 16K )
0.63 x ( Basic wind speed ) ^2
1391.67 N/m^2
=
Design Wind Pressure ( q ) =
=
50.3 m/s
113.11 miles/hr
225.54
509.85
735.38
kg/m^2
kg/m^2
kg/m^2
75 deg. C
199000
199000
MPa
MPa
199000 / 199000 =
1.0000
Uncorroded condition
Thickness of the top course of tank =
Diameter of the tank =
H1 =
8.00 mm
6.000 m
Corroded condition
Corroded thickness of the top course of tank =
Diameter of the tank =
H1 =
5.00 mm
6.00 m
( Cl. 5.9.7.1 & M.6 API 650)
Uncorroded condition
Corroded condition
Sum of
Height of
t actual t uniform Transposed trans.
Course course in
in mm
in mm
width in m Width in
m
m
12
0
0
8
0.00
0.00
11
0
0
8
0.00
0.00
10
0
0
8
0.00
0.00
9
0
0
8
0.00
0.00
8
0
0
8
0.00
0.00
7
0
0
8
0.00
0.00
6
0.5
8
8
0.50
0.50
5
1.5
8
8
1.50
2.00
4
1.5
8
8
1.50
3.50
3
1.5
8
8
1.50
5.00
2
1.5
10
10
1.50
6.50
1
1.5
10
10
1.50
8.00
Sum of
t actual t uniform Transposed trans.
in mm
in mm width in mm Width in
m
0
5
0.00
0.00
-3
5
0.00
0.00
-3
5
0.00
0.00
-3
5
0.00
0.00
-3
5
0.00
0.00
-3
5
0.00
0.00
5
5
0.50
0.50
5
5
1.50
2.00
5
5
1.50
3.50
5
5
1.50
5.00
7
7
1.50
6.50
7
7
1.50
8.00
uncorroded 8.00 m
uncorroded 27.02 m
Wtr corroded
H1 corroded
8.00 m
8.34 m
Transposed width =
Transposed width =
Transposed width =
Transposed width =
4.0000 m
0.00 m
0.00 m
0.00 m
t actual
in mm
Uncorroded
weight in kg
C.A. in
mm
Corroded
weight in kg
0
0
0
0
0
0
8
8
8
8
10
10
0.00
0.00
0.00
0.00
0.00
0.00
592.63
1777.89
1777.89
1777.89
2222.36
2222.36
10371.03
3
3
3
3
3
3
3
3
3
3
3
3
0.00
0.00
0.00
0.00
0.00
0.00
370.39
1111.18
1111.18
1111.18
1555.65
1555.65
6815.25
Uncorrod
ed area
in cm^2
0.00
0.00
0.00
0.00
0.00
0.00
40.00
120.00
120.00
120.00
150.00
150.00
700.00
Corrode Distance y
d area in from top in
cm^2
cm
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
25.00
25.00
75.00
125.00
75.00
275.00
75.00
425.00
105.00
575.00
105.00
725.00
460.00
800.00
421.43 cm
378.57 cm
Uncorroded
Uncorroded
432.61 cm
367.39 cm
Corroded
Corroded
Bottom Plate
6( 1/4") + C.A.
6+3
9.00 mm
4.9 * D * ( H-0.3) / t
4.9 x 6 ( 9.564 - 0.3 ) / 10
27.24 MPa
<=
Thickness provided =
10.00 mm
10.0 mm
0.0 mm
6+3
9.00 mm
Sketch plate
Annular plate
0.00
2479.08
2479.08
190Mpa
( Table 5-1 API 650 )
( t <= 19 mm )
IS 2062 Gr B
IS 2062 Gr B
approx.
approx.
approx.
Cone Roof
Diameter of the Tank =
6.00 m
15 deg.
15.00 deg.
1:16
3.576 deg.
1.5 mm
0.2618 rad
=
0.0624 rad
( Cl. 5.10.4.1 API 650 )
5.0(3/16 inch)+1.5mm
6.50 mm
8.00 mm
2036.45 kg
1654.62 kg
Uncorroded weight
Corroded weight
80 x
80 x
8
Wh
5
2.3
=8
6.00 m
8.0 mm
8.0 mm
15.00 deg.
14.9996 kPa
mm
th = 6.5 mm (corroded)
Wc = 73.48 mm
theta = 15 deg.
R2 = 11591.11 mm
tc = 5 mm (corroded)
Rc = 3000 mm
Fig. F-2 Detail b API 650
=
=
=
=
5.0 mm
6.5 mm
3000.0 mm
11591.1 mm
0.3 ( R2 x th )^0.5 or 300 mm whichever is less
0.3 ( 11591.11 x 6.5 )^0.5
or
300.0 mm
82.35 mm
or
300.0 mm
82.35 mm
=
=
=
0.6 ( Rc x tc )^0.5
0.6 ( 3000 x 5 )^0.5
73.48 mm
( Wh x th ) + ( Wc x tc ) + Area of curb angle
( 82.35 x 6.5 ) + ( 73.48 x 5 ) + 1216
2118.67 mm^2
=
21.19 cm^2
IS 2062 Gr B
250.00 MPa
1.2195
D^2 ( P - 0.08 th )
1.1 tan ( theta )
1768.53 mm^2
17.69 cm^2
This is applicable only when operating external pressure exceeds 0.25 kPa = 25.5 mm w /c & up to 6.9 kPa
6.000
14345.9
28.274
4.976
1.00
0.00
5.00
m
kg
m^2
kPa
kPa
kPa
kPa
Unstiffened Shell :
[ D / ts min ]^0.75 =
( Hts / D ) =
( Fy / E )^0.5 =
1.1465
0.6667
0.035
6.00
8.000
5.00
4.000
250
200000
7.00
7.00
6.50
4
mtr
mtr
mm
mtr
Mpa
Mpa
mm
mm
mm
mtr
0.02702
>
0.00675
V.3.1 Defination
Kg = Wind gust factor =
1.1
Kh = Wind height factor =
1.1
V =specified design wind velocity =
169.20 kPa
3.1535
5.00
kPa
kPa
4.9999
kPa
Ns +1 = Ls / H safe
Ns +1 = 4 / 3.336 =
1.1991
Ns =
0.1991
+ ve value of Ns indicates that stiffeners are required
5.888
6
1000 Ps Ls
19999.49 N/m
65
0 thk
3
145.26
6 thk
2
It. Mkd.
1
2
3
Section
marked
1
2
3
Iyy =
x , cm
0
6.5
0.45
y , cm
0
0.6
14.53
Size cm x cm
Area cm^2
d in cm
0x0
0.6 x 6.5
14.53 x 0.45
0.00
3.90
6.54
10.44
0.00
3.25
6.73
M=Axd
cm^3
0.00
12.68
43.96
56.63
Iaa cm^4
Igg cm^4
0.00
41.19
295.62
336.81
0.00
13.73
0.11
13.84
cm^4
206
Mpa
0.4 x 206
=
82.4
Mpa
Minimum value of fc =
103
Mpa
Allowable compressive stress ( fc ) =
103
Mpa
Area required ( A req ) =
Q D / 2 fc
=
19999.49 x 6 / ( 2 x 103 )
=
582.51 mm^2
=
5.83 cm^2
Web size
Toe size
Quantity =
65 mm x 6 mm thk
0 mm x 0 mm thk
Total for each
Nos.
Weight
58.41 kg
0.00 kg
58.41 kg
67.17 kg
47.00 m/sec
52.78 m/sec
=
=
169.20 km/hr
190.00 km/hr
(105.75 / 118.75)^2 =
=
=
105.75 mph
118.75 mph
0.793
q (psf)
q (kg/m^2)
m Multi.
18 psf
30 psf
87.88 kg/m^2
146.47 kg/m^2
1.000
1.000
6.000 m
8.00 m
8.00 m
0.978
6.5 x 87.88 x 8
4569.95 kg
Area of roof =
upward Wind force of the roof =
28.274 m^2
28.274 x 146.47
4141.42 kg
Internal Pressure =
Upward Force ( Fpi ) =
1529.530 kg/m^2
1529.53 x 6^2 x pi / 4
43246.44 kg
Fpi x D / 2
43246.44 x 6 / 2
129739.33 kg-m
7.00 mm
250.00 MPa
=
=
=
=
q x m^2
(kg/m^2)
87.88
146.47
59 tb ( Fby . H )^0.5
59 x 7 x ( 250 x 9.564 )^0.5
20194.75 N/m
2058.59 kg/m
9.564 m
( As per 5.11.2 )
Corroded condition
Corroded weight of tank
Weight of corroded shell
Weight of stairway + Platform @ 0 kg/m
Weight of Nozzles
Weight of roof plates
Weight of roof structure @ 20 kg/m^2
Weight of handrail on roof @ 20 kg/m run
Weight of wind girder
Weight of Curb Angle
Weight of external stiffener
6815.25 kg
0.00 kg approx.
750.00 kg approx.
1654.62 kg
565.49 kg approx.
376.99 kg approx.
0.00 kg
178.78 kg
67.17 kg approx.
10408.29 kg approx.
Wc x D / 2
10408.29 x 6 / 2
31224.88 kg-m
0.6 Mw + Mpi =
=
MDL / 1.5 =
20816.59 kg-m
Mw + 0.4Mpi =
( MDL + MF ) / 2 =
=
( 31224.88 + 116410.4 ) / 2
73817.64 kg-m
4 x Mw / D
4 x 30704.09 / 6
20469.39 kg
Internal Pressure =
Upward Force =
1529.53 kg/m^2
1529.53 x 6^2 x pi / 4
43246.44 kg
Total Uplift =
20469.39
63715.83 kg
10408.29 kg
43246.44
Design For Anchor Bolts on basis of wind load and internal presure
Material of Anchor bolts
Yield Strength of Bolt material
Tensile Strength of Bolt material
SA 193 GR.B7
482.80
620.74
27
16
1201.66 mm Number of bolts selected are O.K.
3000.00 mm
( Cl. 5.12.3 API 650 )
21.875 mm
375.83 mm^2
53307.54 / 16
3331.72 kg
32684.19 N
86.97 N/mm^2
140.00 N/mm^2
N/mm2
N/mm2
Hence Safe
Depth of Anchor Bolts
Corroded dia of bolt =
Bond strength of concrete =
Perimeter of bolt =
Depth of Bolts required =
Provided Depth =
25.00 mm
8.20 kg/cm^2
7.85 cm
51.733 cm
1500.00 mm
517.33 mm
Hence Safe
Test Condition
Weight of tank ( Uncorroded )
Weight of shell
Weight of stairway + Platform @ 0 kg/m
Weight of Nozzles
Weight of roof plates
Weight of roof structure @ 30 kg/m^2
Weight of handrail on roof @ 20 kg/m run
Weight of wind girder
Weight of Curb Angle
Weight of external stiffener
10371.03 kg
0.00 kg approx.
750.00 kg approx.
2036.45 kg
565.49 kg approx.
376.99 kg approx.
0.00 kg
178.78 kg
67.17 kg approx.
14345.91 kg approx.
4 x Mw / D
4 x 30704.09 / 6
20469.39 kg
Test Pressure =
Upward Force =
1.25 x 1529.53
1911.91 kg/m^2
1911.9125 x 6^2 x pi / 4
54058.05 kg
Total Uplift =
20469.39
74527.45 kg
14345.91 kg
Net Uplift =
74527.45
60181.54 kg
54058.05
14345.91
+ve Value of Net Uplift indicates that Anchor Bolts are required.
Design For Anchor Bolts on basis of Test Condition
Provide M27 size of Anchor Bolts
No. of Bolts Provided
Hence spacing between the bolts
Maximum spacing between the bolts
Root dia. of the bolts = ( 27 - 0 ) x 0.875
Root area of the bolts
27
16
1201.66 mm Number of bolts selected are O.K.
3000.00 mm
( Cl. 5.12.3 API 650 )
23.625 mm
( Uncorroded )
438.36 mm^2
60181.54 / 16
3761.35 kg
36898.80 N
84.17 N/mm^2
140.00 N/mm^2
Hence Safe
Depth of Anchor Bolts
Provide M27 size of Anchor Bolts
Bond strength of concrete =
Perimeter of bolt =
Depth of Bolts required =
Provided Depth =
27
8.20 kg/cm^2
8.48 cm
43.26 cm
1500.00 mm
Hence Safe
8.2 x 1.25 =
=
10.25 kg/cm^2
432.62 mm
Seismic Analysis
6.00 m
8.00 m
9.56 m
1529.530 kg/m^2
IS 2062 Gr B
250.00 MPa
1.50 m
0.978
3.00 mm
3.00 mm
Overturning Moment due to Seismic applied to the Bottom of Shell shall be determined by
Mrw =
Zl [ C1 Ws Xs + C1 Wr Ht + C1 W1 X1 + C2 W2 X2 ]
Constants
D=
D/H=
6.00 m
0.63
H=
9.564 m
0.58
1.81 k ( D )^0.5
2.571
W1 / Wt =
W2 / Wt =
( W1 ) Weight of effective mass of the tank contents that
move in unison with the tank shell =
0.75 S / T
0.75 x 2 / 2.571
0.5833
x( D )^2 x H x density/4
264464.83 kg
2594399.98 N
0.86
0.18
2231183.99 N
466992.00 N
X1 / H =
X2 / H =
0.44
0.8
4.21 m
7.65 m
10371.03 kg
101739.76 N
3.786 m
27278.89
27278.89 N
=
Moment at Base
M=
M=
Zl [ C1 Ws Xs + C1 Wr Ht + C1 W1 X1 + C2 W2 X2 ]
Z*I=
0.32
Shear force
C1 Ws Xs =
C1 Wr Ht =
C1 W1 X1 =
C2 W2 X2 =
Total =
231094.60
130938.66
5633470.18
2084227.78
8079731.22
19534.03
5237.55
428387.3254
87170.29
540329.19 N
2585513.99 N-m
263559.02 kg-m
Resistance to Overturning
( WL ) Maximum weight of the tank contents that may be
used to resist the shell overturning moment =
Thickness of the bottom plate under the shell
Corrosion Allowance for the bottom plate =
( tb )Corroded thk. of the bottom plate under the shell =
( Fby ) Minimum specified yield strength of the bottom =
( G ) Design Specific Gravity =
( H ) Maximum Design liquid level =
WL =
99 tb ( Fby x G x H )^0.5
10.00 mm
3.00 mm
7.00 mm
250.00 MPa
0.978
9.56 m
99 x 7 ( 250 x 0.978 x 9.56 )^0.5
33511.28 N/m
Maximum value of WL =
=
=
196 G H D
196 x 0.978 x 9.564 x 6
10999.75 N/m
Hence ,WL =
10999.75 N/m
Shell Compression
Weight of tank shell and portion of the fixed roof supported by shell ( Wt )
Weight of shell
Weight of stairway + Platform @ 0 kg/m
Weight of Nozzles
Weight of roof plates
Weight of roof structure @ 20 kg/m^2
Weight of handrail on roof @ 20 kg/m run
Weight of wind girder
Weight of Curb Angle
10371.03 kg
0.00 kg approx.
750.00 kg approx.
2036.45 kg
565.49 kg approx.
376.99 kg approx.
0.00 kg
178.78 kg
Total weight
14278.74 kg approx.
Wt =
=
757.51
7431.18
Now,
( Wt + WL ) =
[ D^2 ( Wt + WL ) ] =
M / [ D^2 ( Wt + WL ) ] =
18430.93 N/m
663513.5073
3.90
of shell circumference
Wt + 1.273 M / D^2
7431.18 + 1.273 x 2585513.99 / 6^2
98857.83 N/m
b / 1000 t
14.12 N/mm^2
44
Formula 1
Maximum Allowable Compressive Stress ( Fa ) =
=
=
Maximum value of Fa =
0.5 x Fty
0.5 x 250
125.00 MPa
=
=
Hence Fa =
Maximum longitudinal stress ( Sb ) =
59.71 MPa
14.12 MPa
Hence O.K.
Minimum Anchorage
Material for Anchor Bolts
Yield Strength of Anchor bolt material (Fy)=
Provide M27 size of Anchor Bolts
No. of Bolts Provided
Hence spacing between the bolts
Maximum spacing between the bolts
Root dia. of the bolts = ( 27 - 2 * 1 ) x 0.875
Root area of the bolts
SA 193 GR B7
482.80 N/mm^2
27
16
1203.62 mm Number of bolts selected are O.K.
3000.00 mm
( Cl. 3.12.3 API 650 )
21.875 mm
375.83 mm^2
Minimum Anchorage =
1621246.35 / 16
101327.90 N
269.61 N/mm^2
0.8 Fy
386.24 N/mm^2
Hence Safe
Depth of Anchor Bolts
Corroded dia of bolt =
Bond strength of concrete =
Perimeter of bolt =
Depth of Bolts required =
Provided Depth =
27.00 mm
10.91 kg/cm^2
8.48 cm
111.66 cm
1500.00 mm
Hence Safe
1116.56 mm
Uplift due to Seismic & Internal Pressure ( As per API 650 Table 3-21 a)
Uplift load =
(4 Ms/D)-W2
Diameter of Tank D=
6.0 m
2585513.99 N-m
8753.68 kg
85873.56 N
corroded
27
16
1282.16 mm Number of bolts selected are O.K.
3000.00 mm
21.000 mm
( Uncorroded )
346.36 mm^2
1637802.43 / 16
102362.65 N
482.8 N/mm2
295.54 N/mm^2
386.2 N/mm^2
( Table 3-21 a)
Hence Safe
Depth of Anchor Bolts
Bond strength of concrete =
Perimeter of bolt =
Depth of Bolts required =
Provided Depth =
10.91 kg/cm^2
8.48 cm
112.80 cm
1500.00 mm
Hence Safe
1127.96 mm
P=
40
175
150
32
52
70
6180
3003
60.601
44
29.175
70
110
268
16
95
10
20
10
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
mm =
1.575
6.890
5.906
1.260
2.047
2.756
243.307
118.228
2.386
1.732
1.149
2.756
4.331
10.551
0.630
3.740
0.394
0.787
0.394
design load in N =
36898.80 N=
32684.19 N=
106416.62 N=
Z = reduction factor =
159624.9 N
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
inches
3761.35
3331.72
10847.77
10847.77
375.83
482.80
35.873
175
f
b
radius
c
k
t
A
e
m
Shell thk + Pad thk
w
Q
pcd
N/mm^2
kips
OR
c=
25 Ksi =
1757.72
kg/cm^2
Client
Title :
Doc. No. :
Tag. No. :
IBIC-198-200-ESS-T1044-0001
T1044
Made by
Checked by
Approved by
Revision: 0
5/1/2015
PRODUCT STORED
TANK DIM.
TANK HEIGHT
MAX. PUMP OUT RATE
MAX. PUMP IN RATE
CAPACITY OF TANK
CROSS SECTIONAL AREA OF SHELL
CROSS SECTIONAL AREA OF ROOF
TOTAL AREA
FLASH POINT
:
:
:
:
:
:
:
:
:
:
RAW WATER
6.00
8.00
20.00
20.00
226.19
28.27
28.27
56.55
> 37.8
m
m
m/ hr
m/ hr
m
m2
m2
m2
0
C
As per the standard practice, we design bleeder vent for 1.15 times its pump in / out rate capacity
Add 15% extra to cater for tank drainage in case of pump out condition.Hence
DESIGN FILLING RATE
DESIGN EMPTYING RATE
:
:
23
23
m/ hr
m/ hr
23
m/ hr
= 0.94 x Re
= 21.62
=
=
=
=
50.60
0.00
Q1+Q2+Q5
72.22
m/ hr
m/ hr
m/ hr
m/ hr
:
:
23
226.19
m/ hr
m
= 1.01 x Ri
= 23.23
m/ hr
m/ hr
m/ hr
=
=
=
=
50.60
0.00
Q3+Q4+Q5
73.83
=
=
=
=
=
=
AxV
A x k x (2 x g x h)0.5
9.81
m/sec
0.625
1.22
kg/m3
3
inch
Neck Wall Thickness in mm =
5.49
OD -( 2 X 5.49) =
=88.9-(2*5.49)
77.92
mm
Pi() / 4 *(77.92/1000 )^2
0.0048
OD = 88.9
m2
m/ hr
=
=
=
=
= 1529.53
Kg/m^2
= 50.24/1.22
= 1253.71
mm of Air
=
=
=
=
=
AxV
A x k x (2 x g x h)0.5
0.0048 X 0.625 X ( 2 X 9.81 X 1253.713 )^0.5
0.4674
m/sec
1682.75
m/hr
6 mtr
8 mtr
Tank dia =
Tank Height =
Gujarat (Dahej)
10371.0 kg
15 deg.
0.0
2479.1
687.4
17873.6 kg Appx per tank
0.0 +
0.00 =
IS 2062 GR A / B OR A 36 =>
NOS OF TANK =
1 nos
TOTAL =
4. SPECIALS :
1 Stress relieving of tank outside of foundation - REQURED for Cleanout door - 1 Nos
Required for Compression Girder
150.8
9.6
29.7
8.0
0.0
8.7
47.9
29.7
284.3
16.0
TOTAL =>
FOR
Internal surface
TANK =
System C of spec
shell, COMPLETE
bottom
= Roof plates =
= Roof structure =
= Floating Roof Support =
=Pontoon inside =
FOR
TOTAL =>
TANK =
284.3 m^2
150.80
28.84
29.69
23.75
0.00
0.00
233.1
233.1
3
4 CIVIL REQUIREMENT
5
6
7
8
m^2
m^2
m^2
m^2
m^2
m^2
m^2
m^2
m^2
mtr long
FIRE FIGHTING REQD, TO BE CONSIDERED SEPERATLY ( Foam and Cooling water system )
CATHODIC PROTECTION IF TO BE CONSIDERED SEPERATLY
PLEASE CONSIDER NOZZLE PIPE ( EXTRA STRONG) AND FLANGES AS PER SPECIFICATION
INSTRUMENTS AND CONTROLS SHALL BE TO p & I AND DATA SHEET EXTRA
( Level Instruments, temp instruments, vent etc..)
m^2
m^2
m^2
m^2
m^2
m^2
m^2
m^2