IDM96 (N00407) English
IDM96 (N00407) English
IDM96 (N00407) English
IDM 96
Multimeter
Characteristics
Three LED displays
Waveform capture in the Modbus buffer for all three phases (current and voltage)
Free included configuration and monitoring software with the instrument
THD measurement for current and voltage. Harmonics (up to 63th )
measurements, which can be viewed through software in form of table or
histogram
Easy configuration through keyboard or software
Universal three phase connection, balanced and unbalanced load, or single phase.
Plugable serial communication RS 485 (optional) protocol Modbus RTU
Universal auxiliary supply 85...265VAC/90...300VDC
Protection degree IP50 (housing) and IP20 (connectors)
Accuracy class 0,5%
Technical data
Input
Housing
Fastening
Pair of clamps
Protection degree
IP50 housing
IP20 connectors
Weight
~ 0,45 kg
Voltage (Vn)
Current (In)
0500VAC phase-phase
1A , 5A
Signal limit
U = 10120%
I = 10...120%
Consumption
2mA.
0,2VA.
Climatic conditions
Nominal
frequency
50; 60 Hz 10%
Permanent: 1,5 x Un ; 2 x In
Short time: 4 x U/1s; 50 x I/1s
Maximum: 250A /1s
Overload
Operating temperature
-20...+60C
Display temperature
-20...+55C
Storage temperature
-40...+80C
75%
Auxiliary supply
85 265VAC/90300VDC
Consumption ~ 6VA
Relative humidity
Communication
Influence variables
Error limit
0,5%
I = 10%...100%;
U = 10%...100%
U = 10120%
I = 10...120%
Input:
Frequency:
Additional error input 1,2xI
or 1,2xU
Linearity deviation
0,2%
0,2%
(included in the error limit)
0,2%/10 K;
Nominal Temperature 25C
Temperature error
Auxiliary supply
85 265VAC/90300VDC
Electrical Tests
Test voltage
Mechanical tests
Impact
Vibration
Variables
Variable
Voltage L1 and Neutral
Voltage L2 and Neutral
Voltage L3 and Neutral
Voltage L1 and L2
Voltage L2 and L3
Voltage L3 and L1
Current I1
Current I2
Current I3
Active power P1
Active power P2
Active power P3
Total Active Power PT
Reactive power Q1
Reactive power Q2
Reactive power Q3
Total Reactive Power QT
Apparent power Q1
Apparent power Q2
Apparent power Q3
Total Apparent Power QT
Power Factor 1
Power Factor 2
Power Factor 3
Power Factor T
Frequency
Current demand 1
Current demand 2
Current demand 3
Active Power Demand
Reactive Power Demand
Apparent Power Demand
Cos Phi 1
Cos Phi 2
Cos Phi 3
Cos Phi T
THD Voltage 1
THD Voltage 2
THD Voltage 3
THD Current I1
THD Current I2
THD Current I3
Dimensional (mm)
Access
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Display/Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Caution
Be sure that all connected voltage and current are
compatible with the technical specification and if the
connection are in accordance with the connections
diagrams.
Mounting Instructions
The installation must regard the climatic conditions. It is
important verify the vibration, dust, temperature and
humidity, which must be in the specified limit. The
mechanical fastening in the panel door is done through a
pair of clamps, which is included with the instrument. The
connection of the input voltage, auxiliary supply and RS 485
should be done though pin terminal. The connections of the
input current should be done though lug terminal.
User guide
Verify the connection diagrams and user manual to
configure the instrument. Configure the PT ratio and the CT
primary, connection, and communication (address, baud
rate and byte are according to the local installation.
Product specification
IDM-96
Nominal frequency
50 Hz
60Hz
Connection (Universal)
Single phase/ Three phase
Current signal
1A
5A
Voltage signal
0500Vca (phase-phase)
Auxiliary Supply
85265VAC / 90300VDC
Interface
With RS485
Without RS485
Additional information
Standard configuration:
Default configuration, class 0,5%.
Special configuration
Inform a special configuration
Example:
Frequency:60Hz
Input current: 5A
Input voltage: 0500Vca (phase-phase)
Auxiliary supply:
85265VAC/90300VDC
Interface: Without RS485
Standard Configuration
Code: N0040772424311
N 0 0 4 0 7
1
2
4
1
2
4
3
1
2
1
C
Contact
ABB Ltda.
Avenida dos Autonomistas, 1496
Osasco So Paulo - Brazil
Zip code 06020-902
Telephone 0800 014 9111
Email: abbatende@br.abb.com
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders,
the agreed particulars shall prevail. ABB BR
does not accept any responsibility whatsoever
for potential errors or possible lack of
information in this document.
CopyRight 2012
All rights reseverd