Siemens
Siemens
Siemens
www.usa.siemens.com/3WLIEC
Introduction
8
9
16
23
30
37
44
66
67
69
Overview
Standards
Used in
Industry
Applications/
Individual components
Residential
buildings
Page
Non-residential
buildings
Devices
--
--
--
Rating Plugs
51
--
Ground-fault modules
51
--
Displays
51
--
Current transformers
for N conductor protection
51
--
EMC filters
51
--
More accessories
for Electronic Trip Units
52
--
Locking devices
52
--
Locking mechanisms
53
--
Interlocks
54
--
= 3 2 0 0 A
N S E 0 _ 0 0 9 9 2 b
G F M
5 1
g T R IP
A L A R M
A L A R M
T R IP
C
O F F
J g (s )
.5
B
D
.4
.3
.2
.1
A T 4 5 B
1 2 Jg
.1
.2
.3
.4
.5
N S E 0 _ 0 1 0 2 7 a
N S E 0 _ 0 1 6 0 9
N S E 0 _ 0 0 9 9 0 a
F 7
N S E 0 _ 0 0 9 9 9 a
NSE0_00982
NSE0_00987
NSE0_00989
Test devices
Applications/
Individual components
Standards
Used in
Industry
Page
Residential
buildings
Devices
Non-residential
buildings
Introduction
Ch. 12
IEC 60947-6-1
DIN VDE 0660-114
--
--
54
UL 508
CSA 22.2 No. 14
Indicators, control
elements
55
--
Auxiliary conductor
connections
56
--
Auxiliary releases
57
--
Operating mechanisms
57
--
N S E 0 _ 0 1 2 6 9
N S E 0 _ 0 0 9 9 5 a
Auxiliary contacts
57
--
58
--
Arc chutes
58
--
58
--
Grounding connection
59
--
Support brackets
59
--
CubicleBUS modules
59
--
Parameterization systems 59
--
Accessories for
communications
60
--
60
--
--
NSE0 01018a
Device
PROFIBUS DP
CubicleBus
NSE-01025
NSE-01010
Size I
Size III
Size II
Number of poles
I, II, III
II
3-pole, 4-pole
3-pole, 4-pole
... 690/1000/1150
--
-... 1000
Rated operational
voltage Ue
V AC
V DC
Rated ultimate
short-circuit breaking
capacity at 500 V AC
Size I
Size II
Size III
kA
55/66/85
66/80/100
100/150 (3-pole),
130 (4-pole)
30/25/20
(at 300/600/1000 V DC)
Operating
cycles
Up to 20000
15000
10000
15000
Mounting position
30 30
30 30
NSE0_00062a
NSE0_00061a
Degree of protection
With cover
Without cover
(with door sealing frame)
Dimensions
3-/4-pole
T
Fixedmounted
IP55
IP41
W mm
320/410
460/590
704/914
460/590
H mm
434
434
434
434
D mm
291
291
291
291
465.5
471
465.5
471
465.5
471
465.5
471
ETU15B1)
ETU25B
ETU27B
ETU45B
ETU76B
Overload protection
Short-time delayed
short-circuit protection
--
Instantaneous
short-circuit protection
--
--
Ground-fault protection
--
--
--
--
--
LCD, 4-line
--
--
--
--
LCD, graphic
--
--
--
--
Communication
--
--
--
--
--
--
--
--
--
--
--
--
--
--
CubicleBUS
--
--
--
Rating Plug
NSE0_01111a
NSE0_01108a
Type
NSE0_01106a
NSE0_01107a
NSS0_00535
NSE0_00062a
NSE0_00061a
IP55
IP41
Withdrawable H mm
D mm
30 30
30 30
NSE0_01109a
Endurance
Standard
-- Not available
Optional
1)
II
Type
3WL11
3WL12
Breaking capacity
III
3WL13
C
3-pole
C
4-pole
kA
kA
kA
55
55
121
66
66
145
85
85
187
66
66
145
80
80
176
100
100
220
100
100
220
150
150
330
130
130
286
kA
kA
kA
55
55
121
66
66
145
85
85
187
66
66
145
80
80
176
100
100
220
100
100
220
150
150
330
130
130
286
kA
kA
kA
42
42
88
50
50
105
66
66
145
50
50
105
75
75
165
85
85
187
85
85
187
150
150
330
130
130
286
----
----
509)
509)
1059)
----
----
50
50
105
50
50
105
704)
704)
1544)
704)
704)
1544)
55
42
29.5
24
66
50
35
29
75
66
46
44
66
55
39
32
80
66
46
44
100
80
651)/702)
501)/652)
100
100
80
65
100
100
80
65
100
100
80
65
55
42
--
66
50
--
75
66
509)
66
50
--
80
75
--
100
85
504)
100
85
504)
100
100
704)
100
100
704)
Icu
Ics
Icm
Icw3)
0.5 s
1s
2s
3s
kA
kA
kA
kA
kA
kA
kA
Size
II
Type
3WL12
Breaking capacity
DC
DC
Icc
Icc
Icc
Icc
kA
kA
kA
kA
35
30
25
20
kA
kA
kA
kA
-355)/306)/257)/208)
---
Abbreviations*
(functions)
Explanation
Overload protection
Short-circuit protection
(short-time delayed)
DC
Instantaneous
Short-circuit protection
(instantaneous)
Neutral Protection
Neutral conductor
protection
Ground Fault
Ground-fault protection
Note:
For further technical specifications see
IEC WL Technical Guide 2014
1)
5)
2)
At Ue = 220 V DC.
6)
3)
At Ue = 300 V DC.
At a rated voltage of 690 V the Icw value of the circuit breaker cannot be
greater than the Icu or Ics value at 690 V.
7)
At Ue = 600 V DC.
8)
At Ue = 1000 V DC.
9)
6
7
8
5
9
1
25
21
10
19
22
11
23
12
24
18
13
14
20
16
15
NSE0_01887d
17
18
Ethernet
16
17
PROFIBUS
11
19
12
13
14
15
from Release 2
CubicleBUS
7
1
9
3
10
NSE0_01105l
16 powerconfig as of V2.3
17 PLC, e. g. SIMATIC S7
Features
Coordinated communication concept using the PROFIBUS DP
or MODBUS, ranging from 16 A to 6300 A with 3VL molded
case circuit breakers and 3WL air circuit breakers
The high level of modularity of circuit breakers and accessories
allows easy retrofitting of all communication components
Significant additional benefits for the switchgear due to the
possibility of linking up external input and output modules to
the circuit breaker-internal CubicleBUS of the 3WL
Communication:
For air circuit breakers with optional communication function
(ETU45B or ETU76B Electronic Trip Unit)
see pages 9 to 36.
For accessories see pages 59 and 60.
Benefits
Low space requirements
The 3WL air circuit breakers require very little space. Size I
devices (up to 2000 A) fit into a 400 mm wide switchgear panel.
Size III devices (up to 6300 A) are the smallest of their kind.
Size III devices with the construction width of 704mm, fit into an
800mm wide switchgear panel.
Modular design
The following components can be exchanged or retrofitted at a
later stage to allow the circuit breaker to adapt to new changes
in requirements:
Auxiliary Releases
Motorized Operating Mechanisms
Electronic Trip Units
Current Transformers
Auxiliary Circuit Signaling Switches
Automatic Reset Devices
Interlocks
Engagement Operating Mechanisms
The main contact elements can all be replaced in order to increase the endurance of the circuit breaker.
Retrofittable modules for Electronic Trip Units
Modularity is one of the main features of the new 3WL circuit
breakers.
Special LCDs, ground-fault modules, rating plugs and communication modules for the Electronic Trip Units are available for
fast and easy retrofitting and adaptation to changing requirements.
Communication/measurement functions
The use of modern communication-capable circuit breakers
opens up completely new possibilities in terms of start-up,
parameterization, diagnostics, maintenance and operation. This
allows many different ways of reducing costs and improving
Application
As incoming-feeder, distribution, tie, and outgoing-feeder
circuit breakers in electrical installations.
For switching and protecting motors, capacitors, generators,
transformers, busbars and cables.
When connected to an electronic I&C system, the air circuit
breakers offer a wide range of options for monitoring network
events.
A complete family of Siemens circuit breakers cover applications between 16 A and 6300 A with molded case and air circuit
breakers.
The AC devices are available as circuit breakers and non-automatic air circuit breakers. DC devices are only available as nonautomatic air circuit breakers.
Standards
3WL circuit breakers comply with:
IEC 60947-2
IEC 60947-2 Annex F / CISPR 11/22 Class B
Climate-proof according to IEC 60068-2-30.
Conductor cross-sections
Size
Type
I
Up to
3WL11 10
A 1000
A 1000
A 1000
3WL11 12 3WL11 16
II
3WL11 20 3WL12 08 3WL12 10 3WL12 12 3WL12 16 3WL12 20
1250
1250
1210
1600
1600
14902)
2000
1930
1780
800
800
800
1000
1000
1000
1250
1250
1250
1600
1600
1600
2000
2000
2000
Permissible load
for withdrawable
versions
at rear horizontal
main connections
Up to 55 C (Cu bare)
Up to 60 C
(Cu bare)1)
Up to 70 C
(Cu black painted)1)
Main conductor
minimum
cross-sections
Copper bars,
bare
Unit(s) 1
mm2 60 10
2
40 10
2
50 10
3
50 10
1
50 10
1
60 10
2
40 10
2
50 10
3
50 10
Copper bars,
painted black
Unit(s) 1
mm2 60 10
2
40 10
2
50 10
3
50 10
1
50 10
1
60 10
2
40 10
2
50 10
3
50 10
Size
II
Type
Permissible load
for withdrawable
versions at rear
horizontal main
connections
Up to 55 C (Cu bare)
Up to 60 C (Cu
bare)1)
Up to 70 C
(Cu black painted)1)
Main conductor
minimum
cross-sections
Copper bars,
bare
Copper bars,
painted black
III
3200
3020
2870
39504)
3810
3600
4000
4000
4000
5000
5000
5000
5920
5810
5500
Unit(s) 2
mm2 100 10
3
100 10
4
120 10
4x
100 x 10
6x
100 x 10
6x
120 x 10
Unit(s) 2
mm2 100 10
3
100 10
4
100 105)
4
100 10
6
100 10
6
120 10
A 2500
A 2500
A 2280
1)
2)
3)
4)
5)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@32-@@@@
3WL1108-2@@32-@@@@
3WL1110-2@@32-@@@@
3WL1112-2@@32-@@@@
3WL1116-2@@32-@@@@
3WL1120-2@@32-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@32-@@@@
3WL1210-2@@32-@@@@
3WL1212-2@@32-@@@@
3WL1216-2@@32-@@@@
3WL1220-2@@32-@@@@
3WL1225-2@@32-@@@@
3WL1232-2@@32-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@31-@@@@
3WL1108-2@@31-@@@@
3WL1110-2@@31-@@@@
3WL1112-2@@31-@@@@
3WL1116-2@@31-@@@@
3WL1120-2@@31-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
66
3WL1208-2@@31-@@@@
3WL1210-2@@31-@@@@
3WL1212-2@@31-@@@@
3WL1216-2@@31-@@@@
3WL1220-2@@31-@@@@
3WL1225-2@@31-@@@@
3WL1232-2@@31-@@@@
3WL1240-2@@31-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
2)
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
Rated current1)
In
Breaking
capacity Icu = Ics
DT
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
630
800
1000
1250
1600
55
3WL1106-2@@33-@@@@
3WL1108-2@@33-@@@@
3WL1110-2@@33-@@@@
3WL1112-2@@33-@@@@
3WL1116-2@@33-@@@@
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@33-@@@@
3WL1210-2@@33-@@@@
3WL1212-2@@33-@@@@
3WL1216-2@@33-@@@@
3WL1220-2@@33-@@@@
3WL1225-2@@33-@@@@
3WL1232-2@@33-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@34-@@@@
3WL1108-2@@34-@@@@
3WL1110-2@@34-@@@@
3WL1112-2@@34-@@@@
3WL1116-2@@34-@@@@
3WL1120-2@@34-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@34-@@@@
3WL1210-2@@34-@@@@
3WL1212-2@@34-@@@@
3WL1216-2@@34-@@@@
3WL1220-2@@34-@@@@
3WL1225-2@@34-@@@@
3WL1232-2@@34-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
3)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
10
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@32-@@@@
3WL1108-3@@32-@@@@
3WL1110-3@@32-@@@@
3WL1112-3@@32-@@@@
3WL1116-3@@32-@@@@
3WL1120-3@@32-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@32-@@@@
3WL1210-3@@32-@@@@
3WL1212-3@@32-@@@@
3WL1216-3@@32-@@@@
3WL1220-3@@32-@@@@
3WL1225-3@@32-@@@@
3WL1232-3@@32-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@31-@@@@
3WL1108-3@@31-@@@@
3WL1110-3@@31-@@@@
3WL1112-3@@31-@@@@
3WL1116-3@@31-@@@@
3WL1120-3@@31-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
80
3WL1208-3@@31-@@@@
3WL1210-3@@31-@@@@
3WL1212-3@@31-@@@@
3WL1216-3@@31-@@@@
3WL1220-3@@31-@@@@
3WL1225-3@@31-@@@@
3WL1232-3@@31-@@@@
3WL1240-3@@31-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
2)
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
11
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
630
800
1000
1250
1600
66
3WL1106-3@@33-@@@@
3WL1108-3@@33-@@@@
3WL1110-3@@33-@@@@
3WL1112-3@@33-@@@@
3WL1116-3@@33-@@@@
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@33-@@@@
3WL1210-3@@33-@@@@
3WL1212-3@@33-@@@@
3WL1216-3@@33-@@@@
3WL1220-3@@33-@@@@
3WL1225-3@@33-@@@@
3WL1232-3@@33-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@34-@@@@
3WL1108-3@@34-@@@@
3WL1110-3@@34-@@@@
3WL1112-3@@34-@@@@
3WL1116-3@@34-@@@@
3WL1120-3@@34-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@34-@@@@
3WL1210-3@@34-@@@@
3WL1212-3@@34-@@@@
3WL1216-3@@34-@@@@
3WL1220-3@@34-@@@@
3WL1225-3@@34-@@@@
3WL1232-3@@34-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
12
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
Basic price SET, M)
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@32-@@@@
3WL1108-4@@32-@@@@
3WL1110-4@@32-@@@@
3WL1112-4@@32-@@@@
3WL1116-4@@32-@@@@
3WL1120-4@@32-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@32-@@@@
3WL1210-4@@32-@@@@
3WL1212-4@@32-@@@@
3WL1216-4@@32-@@@@
3WL1220-4@@32-@@@@
3WL1225-4@@32-@@@@
3WL1232-4@@32-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
III
4000
5000
4000
5000
100
3WL1340-4@@32-@@@@
3WL1350-4@@32-@@@@
1
1
1 unit
1 unit
103
103
82.000
82.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@31-@@@@
3WL1108-4@@31-@@@@
3WL1110-4@@31-@@@@
3WL1112-4@@31-@@@@
3WL1116-4@@31-@@@@
3WL1120-4@@31-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
100
3WL1208-4@@31-@@@@
3WL1210-4@@31-@@@@
3WL1212-4@@31-@@@@
3WL1216-4@@31-@@@@
3WL1220-4@@31-@@@@
3WL1225-4@@31-@@@@
3WL1232-4@@31-@@@@
3WL1240-4@@31-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@31-@@@@
3WL1350-4@@31-@@@@
3WL1363-4@@31-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
82.000
82.000
90.000
Additional
price
Options
Non-automatic
air circuit breakers2)
AA
None
BB
CB
EB
FB
3)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
13
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@33-@@@@
3WL1210-4@@33-@@@@
3WL1212-4@@33-@@@@
3WL1216-4@@33-@@@@
3WL1220-4@@33-@@@@
3WL1225-4@@33-@@@@
3WL1232-4@@33-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
III
4000
4000
100
3WL1340-4@@33-@@@@
1 unit
103
82.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@34-@@@@
3WL1108-4@@34-@@@@
3WL1110-4@@34-@@@@
3WL1112-4@@34-@@@@
3WL1116-4@@34-@@@@
3WL1120-4@@34-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
43.000
43.000
43.000
43.000
43.000
43.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@34-@@@@
3WL1210-4@@34-@@@@
3WL1212-4@@34-@@@@
3WL1216-4@@34-@@@@
3WL1220-4@@34-@@@@
3WL1225-4@@34-@@@@
3WL1232-4@@34-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
56.000
56.000
56.000
56.000
56.000
59.000
64.000
III
4000
4000
100
3WL1340-4@@34-@@@@
1 unit
103
82.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
3)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
14
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
4000
5000
4000
5000
150
3WL1340-5@@32-@@@@
3WL1350-5@@32-@@@@
1
1
1 unit
1 unit
103
103
82.000
82.000
150
3WL1340-5@@31-@@@@
3WL1350-5@@31-@@@@
3WL1363-5@@31-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
82.000
82.000
90.000
4000
5000
6300
4000
5000
6300
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
2)
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
4)
5)
15
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@35-@@@@
3WL1108-2@@35-@@@@
3WL1110-2@@35-@@@@
3WL1112-2@@35-@@@@
3WL1116-2@@35-@@@@
3WL1120-2@@35-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
45.000
45.000
45.000
45.000
45.000
45.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@35-@@@@
3WL1210-2@@35-@@@@
3WL1212-2@@35-@@@@
3WL1216-2@@35-@@@@
3WL1220-2@@35-@@@@
3WL1225-2@@35-@@@@
3WL1232-2@@35-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
60.000
60.000
60.000
60.000
60.000
63.000
68.000
70.000
70.000
70.000
70.000
70.000
70.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@36-@@@@
3WL1108-2@@36-@@@@
3WL1110-2@@36-@@@@
3WL1112-2@@36-@@@@
3WL1116-2@@36-@@@@
3WL1120-2@@36-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@36-@@@@
3WL1210-2@@36-@@@@
3WL1212-2@@36-@@@@
3WL1216-2@@36-@@@@
3WL1220-2@@36-@@@@
3WL1225-2@@36-@@@@
3WL1232-2@@36-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
16
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@37-@@@@
3WL1108-2@@37-@@@@
3WL1110-2@@37-@@@@
3WL1112-2@@37-@@@@
3WL1116-2@@37-@@@@
3WL1120-2@@37-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
66
3WL1208-2@@37-@@@@
3WL1210-2@@37-@@@@
3WL1212-2@@37-@@@@
3WL1216-2@@37-@@@@
3WL1220-2@@37-@@@@
3WL1225-2@@37-@@@@
3WL1232-2@@37-@@@@
3WL1240-2@@37-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
103 121.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@38-@@@@
3WL1108-2@@38-@@@@
3WL1110-2@@38-@@@@
3WL1112-2@@38-@@@@
3WL1116-2@@38-@@@@
3WL1120-2@@38-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@38-@@@@
3WL1210-2@@38-@@@@
3WL1212-2@@38-@@@@
3WL1216-2@@38-@@@@
3WL1220-2@@38-@@@@
3WL1225-2@@38-@@@@
3WL1232-2@@38-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
17
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@35-@@@@
3WL1108-3@@35-@@@@
3WL1110-3@@35-@@@@
3WL1112-3@@35-@@@@
3WL1116-3@@35-@@@@
3WL1120-3@@35-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
45.000
45.000
45.000
45.000
45.000
45.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@35-@@@@
3WL1210-3@@35-@@@@
3WL1212-3@@35-@@@@
3WL1216-3@@35-@@@@
3WL1220-3@@35-@@@@
3WL1225-3@@35-@@@@
3WL1232-3@@35-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
60.000
60.000
60.000
60.000
60.000
63.000
68.000
70.000
70.000
70.000
70.000
70.000
70.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@36-@@@@
3WL1108-3@@36-@@@@
3WL1110-3@@36-@@@@
3WL1112-3@@36-@@@@
3WL1116-3@@36-@@@@
3WL1120-3@@36-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@36-@@@@
3WL1210-3@@36-@@@@
3WL1212-3@@36-@@@@
3WL1216-3@@36-@@@@
3WL1220-3@@36-@@@@
3WL1225-3@@36-@@@@
3WL1232-3@@36-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
18
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@37-@@@@
3WL1108-3@@37-@@@@
3WL1110-3@@37-@@@@
3WL1112-3@@37-@@@@
3WL1116-3@@37-@@@@
3WL1120-3@@37-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
80
3WL1208-3@@37-@@@@
3WL1210-3@@37-@@@@
3WL1212-3@@37-@@@@
3WL1216-3@@37-@@@@
3WL1220-3@@37-@@@@
3WL1225-3@@37-@@@@
3WL1232-3@@37-@@@@
3WL1240-3@@37-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
103 121.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@38-@@@@
3WL1108-3@@38-@@@@
3WL1110-3@@38-@@@@
3WL1112-3@@38-@@@@
3WL1116-3@@38-@@@@
3WL1120-3@@38-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@38-@@@@
3WL1210-3@@38-@@@@
3WL1212-3@@38-@@@@
3WL1216-3@@38-@@@@
3WL1220-3@@38-@@@@
3WL1225-3@@38-@@@@
3WL1232-3@@38-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
91.000
103
91.000
103
91.000
103
91.000
103
91.000
103 102.000
103 113.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
19
Rated current1)
In
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@35-@@@@
3WL1108-4@@35-@@@@
3WL1110-4@@35-@@@@
3WL1112-4@@35-@@@@
3WL1116-4@@35-@@@@
3WL1120-4@@35-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
45.000
45.000
45.000
45.000
45.000
45.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@35-@@@@
3WL1210-4@@35-@@@@
3WL1212-4@@35-@@@@
3WL1216-4@@35-@@@@
3WL1220-4@@35-@@@@
3WL1225-4@@35-@@@@
3WL1232-4@@35-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
60.000
60.000
60.000
60.000
60.000
63.000
68.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@35-@@@@
3WL1350-4@@35-@@@@
3WL1363-4@@35-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
88.000
88.000
96.000
Size
Breaking capacity DT
Icu = Ics
PU
(UNIT,
Basic price SET, M)
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@36-@@@@
3WL1108-4@@36-@@@@
3WL1110-4@@36-@@@@
3WL1112-4@@36-@@@@
3WL1116-4@@36-@@@@
3WL1120-4@@36-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@36-@@@@
3WL1210-4@@36-@@@@
3WL1212-4@@36-@@@@
3WL1216-4@@36-@@@@
3WL1220-4@@36-@@@@
3WL1225-4@@36-@@@@
3WL1232-4@@36-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
91.000
91.000
91.000
91.000
91.000
102.000
113.000
III
4000
5000
4000
5000
100
3WL1340-4@@36-@@@@
3WL1350-4@@36-@@@@
1
1
1 unit
1 unit
103
103
148.000
148.000
Additional
price
Options
Non-automatic
air circuit breakers3)
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
20
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
7)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
Basic price SET, M)
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@37-@@@@
3WL1108-4@@37-@@@@
3WL1110-4@@37-@@@@
3WL1112-4@@37-@@@@
3WL1116-4@@37-@@@@
3WL1120-4@@37-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
100
3WL1208-4@@37-@@@@
3WL1210-4@@37-@@@@
3WL1212-4@@37-@@@@
3WL1216-4@@37-@@@@
3WL1220-4@@37-@@@@
3WL1225-4@@37-@@@@
3WL1232-4@@37-@@@@
3WL1240-4@@37-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
91.000
91.000
91.000
91.000
91.000
102.000
113.000
121.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@37-@@@@
3WL1350-4@@37-@@@@
3WL1363-4@@37-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
148.000
148.000
166.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@38-@@@@
3WL1108-4@@38-@@@@
3WL1110-4@@38-@@@@
3WL1112-4@@38-@@@@
3WL1116-4@@38-@@@@
3WL1120-4@@38-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
70.000
70.000
70.000
70.000
70.000
70.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@38-@@@@
3WL1210-4@@38-@@@@
3WL1212-4@@38-@@@@
3WL1216-4@@38-@@@@
3WL1220-4@@38-@@@@
3WL1225-4@@38-@@@@
3WL1232-4@@38-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
91.000
91.000
91.000
91.000
91.000
102.000
113.000
III
4000
4000
100
3WL1340-4@@38-@@@@
1 unit
103
148.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
7)
21
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
4000
5000
6300
4000
5000
6300
150
3WL1340-5@@35-@@@@
3WL1350-5@@35-@@@@
3WL1363-5@@35-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
88.000
88.000
96.000
3WL1340-5@@36-@@@@
3WL1350-5@@36-@@@@
1
1
1 unit
1 unit
103 148.000
103 148.000
3WL1340-5@@37-@@@@
3WL1350-5@@37-@@@@
3WL1363-5@@37-@@@@
1
1
1
1 unit
1 unit
1 unit
103 148.000
103 148.000
103 166.000
4000
5000
4000
5000
150
4000
5000
6300
4000
5000
6300
150
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
CB
EB
FB
LSIN4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
22
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51.
5)
6)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@42-@@@@
3WL1108-2@@42-@@@@
3WL1110-2@@42-@@@@
3WL1112-2@@42-@@@@
3WL1116-2@@42-@@@@
3WL1120-2@@42-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@42-@@@@
3WL1210-2@@42-@@@@
3WL1212-2@@42-@@@@
3WL1216-2@@42-@@@@
3WL1220-2@@42-@@@@
3WL1225-2@@42-@@@@
3WL1232-2@@42-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@41-@@@@
3WL1108-2@@41-@@@@
3WL1110-2@@41-@@@@
3WL1112-2@@41-@@@@
3WL1116-2@@41-@@@@
3WL1120-2@@41-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
66
3WL1208-2@@41-@@@@
3WL1210-2@@41-@@@@
3WL1212-2@@41-@@@@
3WL1216-2@@41-@@@@
3WL1220-2@@41-@@@@
3WL1225-2@@41-@@@@
3WL1232-2@@41-@@@@
3WL1240-2@@41-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
75.000
75.000
75.000
75.000
67.000
71.000
77.000
103.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
23
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
630
800
1000
1250
1600
55
3WL1106-2@@43-@@@@
3WL1108-2@@43-@@@@
3WL1110-2@@43-@@@@
3WL1112-2@@43-@@@@
3WL1116-2@@43-@@@@
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@43-@@@@
3WL1210-2@@43-@@@@
3WL1212-2@@43-@@@@
3WL1216-2@@43-@@@@
3WL1220-2@@43-@@@@
3WL1225-2@@43-@@@@
3WL1232-2@@43-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@44-@@@@
3WL1108-2@@44-@@@@
3WL1110-2@@44-@@@@
3WL1112-2@@44-@@@@
3WL1116-2@@44-@@@@
3WL1120-2@@44-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@44-@@@@
3WL1210-2@@44-@@@@
3WL1212-2@@44-@@@@
3WL1216-2@@44-@@@@
3WL1220-2@@44-@@@@
3WL1225-2@@44-@@@@
3WL1232-2@@44-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
24
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@42-@@@@
3WL1108-3@@42-@@@@
3WL1110-3@@42-@@@@
3WL1112-3@@42-@@@@
3WL1116-3@@42-@@@@
3WL1120-3@@42-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@42-@@@@
3WL1210-3@@42-@@@@
3WL1212-3@@42-@@@@
3WL1216-3@@42-@@@@
3WL1220-3@@42-@@@@
3WL1225-3@@42-@@@@
3WL1232-3@@42-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
50.000
50.000
50.000
50.000
50.000
50.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@41-@@@@
3WL1108-3@@41-@@@@
3WL1110-3@@41-@@@@
3WL1112-3@@41-@@@@
3WL1116-3@@41-@@@@
3WL1120-3@@41-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
80
3WL1208-3@@41-@@@@
3WL1210-3@@41-@@@@
3WL1212-3@@41-@@@@
3WL1216-3@@41-@@@@
3WL1220-3@@41-@@@@
3WL1225-3@@41-@@@@
3WL1232-3@@41-@@@@
3WL1240-3@@41-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103 67.000
103 67.000
103 67.000
103 67.000
103 67.000
103 71.000
103 77.000
103 103.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
25
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
630
800
1000
1250
1600
66
3WL1106-3@@43-@@@@
3WL1108-3@@43-@@@@
3WL1110-3@@43-@@@@
3WL1112-3@@43-@@@@
3WL1116-3@@43-@@@@
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@43-@@@@
3WL1210-3@@43-@@@@
3WL1212-3@@43-@@@@
3WL1216-3@@43-@@@@
3WL1220-3@@43-@@@@
3WL1225-3@@43-@@@@
3WL1232-3@@43-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@44-@@@@
3WL1108-3@@44-@@@@
3WL1110-3@@44-@@@@
3WL1112-3@@44-@@@@
3WL1116-3@@44-@@@@
3WL1120-3@@44-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@44-@@@@
3WL1210-3@@44-@@@@
3WL1212-3@@44-@@@@
3WL1216-3@@44-@@@@
3WL1220-3@@44-@@@@
3WL1225-3@@44-@@@@
3WL1232-3@@44-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
3)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
26
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@42-@@@@
3WL1108-4@@42-@@@@
3WL1110-4@@42-@@@@
3WL1112-4@@42-@@@@
3WL1116-4@@42-@@@@
3WL1120-4@@42-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@42-@@@@
3WL1210-4@@42-@@@@
3WL1212-4@@42-@@@@
3WL1216-4@@42-@@@@
3WL1220-4@@42-@@@@
3WL1225-4@@42-@@@@
3WL1232-4@@42-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
III
4000
5000
4000
5000
100
3WL1340-4@@42-@@@@
3WL1350-4@@42-@@@@
1
1
1 unit
1 unit
103
103
99.000
99.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@41-@@@@
3WL1108-4@@41-@@@@
3WL1110-4@@41-@@@@
3WL1112-4@@41-@@@@
3WL1116-4@@41-@@@@
3WL1120-4@@41-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
100
3WL1208-4@@41-@@@@
3WL1210-4@@41-@@@@
3WL1212-4@@41-@@@@
3WL1216-4@@41-@@@@
3WL1220-4@@41-@@@@
3WL1225-4@@41-@@@@
3WL1232-4@@41-@@@@
3WL1240-4@@41-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
103.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@41-@@@@
3WL1350-4@@41-@@@@
3WL1363-4@@41-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
99.000
99.000
108.000
Additional
price
Options
Non-automatic
air circuit breakers2)
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
5)
27
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@43-@@@@
3WL1210-4@@43-@@@@
3WL1212-4@@43-@@@@
3WL1216-4@@43-@@@@
3WL1220-4@@43-@@@@
3WL1225-4@@43-@@@@
3WL1232-4@@43-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
III
4000
4000
100
3WL1340-4@@43-@@@@
1 unit
103
99.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@44-@@@@
3WL1108-4@@44-@@@@
3WL1110-4@@44-@@@@
3WL1112-4@@44-@@@@
3WL1116-4@@44-@@@@
3WL1120-4@@44-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
50.000
50.000
50.000
50.000
50.000
50.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@44-@@@@
3WL1210-4@@44-@@@@
3WL1212-4@@44-@@@@
3WL1216-4@@44-@@@@
3WL1220-4@@44-@@@@
3WL1225-4@@44-@@@@
3WL1232-4@@44-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
67.000
67.000
67.000
67.000
67.000
71.000
77.000
III
4000
4000
100
3WL1340-4@@44-@@@@
1 unit
103
99.000
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
5)
28
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
PS*/
(UNIT, P. unit
SET, M)
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
4000
5000
4000
5000
130
3WL1340-5@@42-@@@@
3WL1350-5@@42-@@@@
1
1
1 unit
1 unit
103
103
99.000
99.000
130
3WL1340-5@@41-@@@@
3WL1350-5@@41-@@@@
3WL1363-5@@41-@@@@
1
1
1
1 unit
1 unit
1 unit
103 99.000
103 99.000
103 108.000
4000
5000
6300
4000
5000
6300
Additional
price
Options
Non-automatic
air circuit breakers2)
Versions without
ground-fault protection
AA
None
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
3)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
4)
29
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@45-@@@@
3WL1108-2@@45-@@@@
3WL1110-2@@45-@@@@
3WL1112-2@@45-@@@@
3WL1116-2@@45-@@@@
3WL1120-2@@45-@@@@
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@45-@@@@
3WL1210-2@@45-@@@@
3WL1212-2@@45-@@@@
3WL1216-2@@45-@@@@
3WL1220-2@@45-@@@@
3WL1225-2@@45-@@@@
3WL1232-2@@45-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
54.000
54.000
54.000
54.000
54.000
54.000
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
75.000
75.000
75.000
75.000
72.000
76.000
82.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@46-@@@@
3WL1108-2@@46-@@@@
3WL1110-2@@46-@@@@
3WL1112-2@@46-@@@@
3WL1116-2@@46-@@@@
3WL1120-2@@46-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@46-@@@@
3WL1210-2@@46-@@@@
3WL1212-2@@46-@@@@
3WL1216-2@@46-@@@@
3WL1220-2@@46-@@@@
3WL1225-2@@46-@@@@
3WL1232-2@@46-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
30
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for
N conductors can be ordered by adding the supplement "Z" and the order
code "F23", see page 40.
5)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@47-@@@@
3WL1108-2@@47-@@@@
3WL1110-2@@47-@@@@
3WL1112-2@@47-@@@@
3WL1116-2@@47-@@@@
3WL1120-2@@47-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
66
3WL1208-2@@47-@@@@
3WL1210-2@@47-@@@@
3WL1212-2@@47-@@@@
3WL1216-2@@47-@@@@
3WL1220-2@@47-@@@@
3WL1225-2@@47-@@@@
3WL1232-2@@47-@@@@
3WL1240-2@@47-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
55
3WL1106-2@@48-@@@@
3WL1108-2@@48-@@@@
3WL1110-2@@48-@@@@
3WL1112-2@@48-@@@@
3WL1116-2@@48-@@@@
3WL1120-2@@48-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
66
3WL1208-2@@48-@@@@
3WL1210-2@@48-@@@@
3WL1212-2@@48-@@@@
3WL1216-2@@48-@@@@
3WL1220-2@@48-@@@@
3WL1225-2@@48-@@@@
3WL1232-2@@48-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for
N conductors can be ordered by adding the supplement "Z" and the order
code "F23", see page 40.
5)
31
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@45-@@@@
3WL1108-3@@45-@@@@
3WL1110-3@@45-@@@@
3WL1112-3@@45-@@@@
3WL1116-3@@45-@@@@
3WL1120-3@@45-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
54.000
54.000
54.000
54.000
54.000
54.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@45-@@@@
3WL1210-3@@45-@@@@
3WL1212-3@@45-@@@@
3WL1216-3@@45-@@@@
3WL1220-3@@45-@@@@
3WL1225-3@@45-@@@@
3WL1232-3@@45-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
72.000
72.000
72.000
72.000
72.000
76.000
82.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@46-@@@@
3WL1108-3@@46-@@@@
3WL1110-3@@46-@@@@
3WL1112-3@@46-@@@@
3WL1116-3@@46-@@@@
3WL1120-3@@46-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@46-@@@@
3WL1210-3@@46-@@@@
3WL1212-3@@46-@@@@
3WL1216-3@@46-@@@@
3WL1220-3@@46-@@@@
3WL1225-3@@46-@@@@
3WL1232-3@@46-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
LSIN4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
32
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for
N conductors can be ordered by adding the supplement "Z" and the order
code "F23", see page 40.
5)
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@47-@@@@
3WL1108-3@@47-@@@@
3WL1110-3@@47-@@@@
3WL1112-3@@47-@@@@
3WL1116-3@@47-@@@@
3WL1120-3@@47-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
80
3WL1208-3@@47-@@@@
3WL1210-3@@47-@@@@
3WL1212-3@@47-@@@@
3WL1216-3@@47-@@@@
3WL1220-3@@47-@@@@
3WL1225-3@@47-@@@@
3WL1232-3@@47-@@@@
3WL1240-3@@47-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
66
3WL1106-3@@48-@@@@
3WL1108-3@@48-@@@@
3WL1110-3@@48-@@@@
3WL1112-3@@48-@@@@
3WL1116-3@@48-@@@@
3WL1120-3@@48-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
80
3WL1208-3@@48-@@@@
3WL1210-3@@48-@@@@
3WL1212-3@@48-@@@@
3WL1216-3@@48-@@@@
3WL1220-3@@48-@@@@
3WL1225-3@@48-@@@@
3WL1232-3@@48-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for
N conductors can be ordered by adding the supplement "Z" and the order
code "F23", see page 40.
5)
33
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@45-@@@@
3WL1108-4@@45-@@@@
3WL1110-4@@45-@@@@
3WL1112-4@@45-@@@@
3WL1116-4@@45-@@@@
3WL1120-4@@45-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
54.000
54.000
54.000
54.000
54.000
54.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@45-@@@@
3WL1210-4@@45-@@@@
3WL1212-4@@45-@@@@
3WL1216-4@@45-@@@@
3WL1220-4@@45-@@@@
3WL1225-4@@45-@@@@
3WL1232-4@@45-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
72.000
72.000
72.000
72.000
72.000
76.000
82.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@45-@@@@
3WL1350-4@@45-@@@@
3WL1363-4@@45-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
106.000
106.000
108.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@46-@@@@
3WL1108-4@@46-@@@@
3WL1110-4@@46-@@@@
3WL1112-4@@46-@@@@
3WL1116-4@@46-@@@@
3WL1120-4@@46-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@46-@@@@
3WL1210-4@@46-@@@@
3WL1212-4@@46-@@@@
3WL1216-4@@46-@@@@
3WL1220-4@@46-@@@@
3WL1225-4@@46-@@@@
3WL1232-4@@46-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
III
4000
5000
4000
5000
100
3WL1340-4@@46-@@@@
3WL1350-4@@46-@@@@
1
1
1 unit
1 unit
103
103
190.000
190.000
Additional
price
Options
Non-automatic
air circuit breakers3)
AA
None
BB
CB
EB
FB
4)
NB
DG
EG
FG
NG
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
Z options which are installed on the guide frame are not available.
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
5)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
6)
Additional price
1)
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
3)
34
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@47-@@@@
3WL1108-4@@47-@@@@
3WL1110-4@@47-@@@@
3WL1112-4@@47-@@@@
3WL1116-4@@47-@@@@
3WL1120-4@@47-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
4000
800
1000
1250
1600
2000
2500
3200
4000
100
3WL1208-4@@47-@@@@
3WL1210-4@@47-@@@@
3WL1212-4@@47-@@@@
3WL1216-4@@47-@@@@
3WL1220-4@@47-@@@@
3WL1225-4@@47-@@@@
3WL1232-4@@47-@@@@
3WL1240-4@@47-@@@@
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000
III
4000
5000
6300
4000
5000
6300
100
3WL1340-4@@47-@@@@
3WL1350-4@@47-@@@@
3WL1363-4@@47-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
190.000
190.000
227.000
630
800
1000
1250
1600
2000
630
800
1000
1250
1600
2000
85
3WL1106-4@@48-@@@@
3WL1108-4@@48-@@@@
3WL1110-4@@48-@@@@
3WL1112-4@@48-@@@@
3WL1116-4@@48-@@@@
3WL1120-4@@48-@@@@
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
84.000
84.000
84.000
84.000
84.000
84.000
II
800
1000
1250
1600
2000
2500
3200
800
1000
1250
1600
2000
2500
3200
100
3WL1208-4@@48-@@@@
3WL1210-4@@48-@@@@
3WL1212-4@@48-@@@@
3WL1216-4@@48-@@@@
3WL1220-4@@48-@@@@
3WL1225-4@@48-@@@@
3WL1232-4@@48-@@@@
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
103
109.000
109.000
109.000
109.000
109.000
123.000
136.000
III
4000
4000
100
3WL1340-4@@48-@@@@
1 unit
103
190.000
Additional
price
Options
Non-automatic
air circuit breakers3)
AA
None
BB
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
Z options which are installed on the guide frame are not available.
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 40.
5)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
6)
Additional price
1)
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
3)
35
Rated current1)
In
Breaking capacity DT
Icu = Ics
PU
PS*/
(UNIT, P. unit
SET, M)
PG
Weight
per PU
approx.
Basic price
per PU
kg
kA
4000
5000
6300
4000
5000
6300
130
3WL1340-5@@45-@@@@
3WL1350-5@@45-@@@@
3WL1363-5@@45-@@@@
1 1 unit
1 1 unit
1 1 unit
103
103
103
115.000
106.000
108.000
3WL1340-5@@46-@@@@
3WL1350-5@@46-@@@@
1 1 unit
1 1 unit
103
103
190.000
190.000
3WL1340-5@@47-@@@@
3WL1350-5@@47-@@@@
3WL1363-5@@47-@@@@
1 1 unit
1 1 unit
1 1 unit
103
103
103
190.000
190.000
227.000
4000
5000
4000
5000
130
4000
5000
6300
4000
5000
6300
130
Additional
price
Options
Non-automatic
air circuit breakers3)
Versions without
ground-fault protection
AA
None
CB
EB
FB
NB
DG
EG
FG
NG
Versions with
ground-fault protection
Operating mechanism,
auxiliary release,
auxiliary switch
1AA2
None
The rated current is determined by the rating plug. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 38.
2)
Z options which are installed on the guide frame are not available.
3)
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 5.
36
4)
Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 51. The
internal current transformers for
N conductors can be ordered by adding the supplement "Z" and the order
code "F23", see page 40.
5)
Additional price
????
Operating mechanisms
Manual operating mechanism with mechanical closing
None
V DC
110
230
220
Closing solenoid
50/60 Hz V AC
V DC
50/60 Hz V AC
V DC
230
220
110
--
24
--
24
Note
To order different voltages for motorized operating mechanism and closing solenoid or
closing coil for synchronization purposes:
"1" at the 13th digit of the Article No. and order codes, see page 39.
Condition
--
Operating range
0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
---
None
--
24
--
30
--
48
--
60
Condition
--
Operating range
0.85 ... 1.1 Us
Undervoltage release,
instantaneous
( 80 ms),
short-delay ( 200 ms)
Operating range
0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
---
None
--
24
--
30
--
48
--
60
--
24
--
30
--
48
--
60
--
--
48
--
Auxiliary switches
1st auxiliary switch block
2 NO + 2 NC
None
4 NO + 4 NC
6 NO + 2 NC
5 NO + 3 NC
Additional price
37
Additional price
3WL....-.....-....-Z
??? +...+...
Operating manuals
Printed version
French/Italian
A 1 1
Spanish/Portuguese
A 1 2
Additional price
3-pole
Additional price
4-pole
Conditions
Size
Rated current In
I1)
Up to 2000 A
A 0 5
II1)
Up to 2000 A
A 0 5
2500 A
A 0 5
3200 A
A 0 5
4000 A
A 0 5
5000 A
A 0 5
6300 A
A 0 5
III1)2)
Size
Rated current In
II
Up to 2000 A
A 1 5
2500 A
A 1 5
3200 A
A 1 5
4000 A
A 1 5
A 1 6
A 0 8
A 0 8
A 0 8
Note
For size III select a circuit breaker with very high breaking capacity C, which can be used
as standard up to 1150 V AC.
Size
Rated current In
Up to 2000 A
Size
Additional price
A 6 1
Rating plugs
Conditions
Additional price
Size
II, III
III
B 0 2
None
315
B 0 3
None
400
B 0 4
None
500
B 0 5
None
630
B 0 6
None
800
B 0 8
None
1000
B 1 0
None
1250
B 1 2
None
1600
B 1 6
None
2000
B 2 0
None
2500
B 2 5
None
3200
B 3 2
None
4000
B 4 0
None
5000
B 5 0
None
6300
B 6 3
None
Additional price
1)
2)
3)
4)
38
3WL....-.....-....-Z
Additional price
??? +...+...
C 1 1
C 1 2
1 NO contact
C 2 0
1 NO contact
C 2 2
Signaling switches2)
C 2 6
C 2 7
S 2 5
S 2 4
T 4 0
2)
1 CO contact
K 0 7
1 NO contact
K 0 6
Type
50/60 Hz V AC
24
K 1 0
48
K 1 1
125
K 1 2
K 1 3
24 ... 30
M0 1
V DC
Conditions
Motor
50/60 Hz V AC
Type
Conditions
--
48 ... 60
M0 3
M0 5
M0 6
--
Activation coils
50/60 Hz V AC
Type
Conditions
Type
Conditions
Opening coils
(shunt release)6)7)
V DC
--
24
M2 1
--
30
M2 2
--
48
M2 3
--
60
M2 4
M2 5
M2 6
Activation coils
50/60 Hz V AC
V DC
V DC
--
24
M3 1
--
48
M3 3
M3 5
M3 6
Activation coils
50/60 Hz V AC
V DC
--
24
M4 1
--
48
M4 3
M4 5
M4 6
Additional price
1)
2)
3)
4)
5)
6)
7)
8)
39
3WL....-.....-....-Z
Additional
price
??? +...+...
S 5 5
R 5 5
R 5 6
R 5 7
3-pole
R 1 0
II
R 1 0
III
R 1 0
R 1 0
II
R 1 0
III
Number of poles Size
R 1 0
3-pole
R 2 1
II
R 2 1
III
R 2 1
R 2 1
II
R 2 1
III
R 2 1
Shutters
2-part
lockable
with padlocks1)
Version
4-pole
4-pole
Connected
position
Test position
Disconnected
position
1 CO
1 CO
1 CO
R 1 5
3 CO
2 CO
1 CO
R 1 6
F 0 1
F 0 2
F 1 2
F 0 5
F 2 3
F 2 3
F 2 3
F 3 1
EMC filters
EMC filters
Common-mode interference suppressor filters
(e.g. in IT networks, caused by frequency converters)
Insertion loss (asymmetric) in the range 40 kHz to 10 MHz >40 dB.
Additional price
1)
2)
3)
40
3WL....-.....-....-Z
Additional
price
??? +...+...
EMERGENCY-STOP pushbuttons
Version
Made by CES
S 0 1
Made by IKON
S 0 3
S 0 5
S 0 7
Made by Ronis
S 0 8
Made by Profalux
S 0 9
S 3 3
Made by CES
R 6 1
Made by Ronis
R 6 8
Made by Profalux
R 6 0
Made by CES
S 7 1
Made by Profalux
S 7 5
Made by Ronis
S 7 6
S 3 0
R 3 0
Version
Version
Version
Version
Made by CES
R 8 1
Made by Ronis
R 8 5
Made by Profalux
R 8 6
Fixed-mounted
N 6 1
Withdrawable
P 6 1
Version
Additional price
1)
2)
41
Additional price
3WL....-.....-....-Z
??? +...+...
For withdrawable circuit breakers with guide frames or for guide frames1)
Note
Additional price
3-pole
Additional price
4-pole
To select this connection method the 12th digit of the Article No. for the circuit breaker
must be a "6".
Connection methods for main connections
Size
Rated current In
Up to 1600 A
P 0 0
II
Up to 2000 A
P 0 0
Up to 2500 A
P 0 0
Up to 3200 A
P 0 0
III
Up to 4000 A
P 0 0
Size
Rated current In
Up to 2000 A
P 0 1
II
Up to 2000 A
P 0 1
Up to 2500 A
P 0 1
Up to 3200 A
P 0 1
III
Up to 4000 A
P 0 1
Size
Rated current In
Top:2)
horizontal
Bottom:
accessible from front,
single hole
Up to 1600 A
P 0 7
II
Up to 2000 A
P 0 7
Up to 2500 A
P 0 7
Up to 3200 A
P 0 7
III
Up to 4000 A
P 0 7
Size
Rated current In
Top:
vertical
Bottom:
horizontal
Up to 2000 A
P 1 8
II
Up to 2000 A
P 1 8
Up to 2500 A
P 1 8
Up to 3200 A
P 1 8
Up to 4000 A
P 1 8
Up to 5000 A
P 1 8
III
Connection methods for main connections
Size
Rated current In
Top:
Connecting flange
Bottom:
horizontal
Up to 2000 A
P 1 9
II
Up to 2000 A
P 1 9
Up to 2500 A
P 1 9
Up to 3200 A
P 1 9
III
Up to 4000 A
P 1 9
Size
Rated current In
Top:
horizontal
Bottom:
vertical
Up to 2000 A
P 2 3
II
Up to 2000 A
P 2 3
Up to 2500 A
P 2 3
Up to 3200 A
P 2 3
Up to 4000 A
P 2 3
Up to 5000 A
P 2 3
III
Connection methods for main connections
Size
Rated current In
Top:
horizontal
Bottom:
connecting flange
Up to 2000 A
P 2 8
II
Up to 2000 A
P 2 8
Up to 2500 A
P 2 8
Up to 3200 A
P 2 8
Up to 4000 A
P 2 8
III
Additional price
1)
Only horizontal connection and vertical connection are available for circuit
breakers with very high breaking capacity C.
2)
42
Additional price
3WL....-.....-....-Z
??? +...+...
Additional price
3-pole
Additional price
4-pole
To select this connection method the 12th digit of the Article No. for the circuit breaker
must be a "2".
Connection methods for main connections
Size
Rated current In
Top:1)
horizontal
Bottom:
accessible from front,
single hole
Up to 1600 A
N 1 1
II
Up to 2000 A
N 1 1
Up to 2500 A
N 1 1
Up to 3200 A
N 1 1
III
Up to 4000 A
N 1 1
Size
Rated current In
Top:
vertical
Bottom:
horizontal
Up to 1600 A
N 2 0
Up to 2000 A
N 2 0
Up to 2000 A
N 2 0
Up to 2500 A
N 2 0
Up to 3200 A
N 2 0
Up to 4000 A
N 2 0
Up to 5000 A
N 2 0
II
III
Connection methods for main connections
Size
Rated current In
Top:
horizontal
Bottom:
vertical
Up to 1600 A
N 2 4
Up to 2000 A
N 2 4
Up to 2000 A
N 2 4
Up to 2500 A
N 2 4
Up to 3200 A
N 2 4
Up to 4000 A
N 2 4
Up to 5000 A
N 2 4
II
III
Additional price
1)
43
Overview
Determination of the number of auxiliary supply connectors required
NSE0_01104
X6
X5
X8
Terminal
X6
b
b1
b2
b3
Operating mechanisms
Manual operating mechanism with stored-energy feature with mechanical closing
Manual operating mechanism with stored-energy feature with mechanical and electrical closing
Manual/motorized operating mechanism with stored-energy feature with mechanical and electrical closing
0
0
+1
X6
X5
c
c1
c2
c3
c4
Connections for external current transformers for overload protection in the N conductor and ground-fault protection
Current transformer installed in the N conductor (required with 3-pole circuit breakers if c2 is not selected)
Current transformer in the neutral point of the transformer (required if c2 or c3 is not selected)
X8
X8
X8
d
d1
d2
Auxiliary releases
With/without 1st auxiliary release (shunt release F1)
2nd auxiliary release (shunt release F2, undervoltage release F3, delayable undervoltage release F4)
e
e1
e2
X6
X5
f
f1
f2
Communication modules
Without communication module COM15/COM16
With communication module COM15/COM16
occupies the entire terminal strip X7, making the following options no longer possible:
Tripped signal switch S24
Stored-energy status indication S21
Electrical ON button S10
Signaling switch on first and second auxiliary release S22 + S23
0
+1
X7
g
g1
g2
g3
g4
g5
g6
g7
g8
Optional signals/accessories
Tripped signaling switch S24 (only when f2 not selected)
Stored-energy status indicator S21 (only when f2 not selected, required if g1 not selected)
Electric ON button S10 (only when f2 not selected, required if g1 or g2 not selected)
Signaling switch at first auxiliary release S22 (only when f2 not selected, required if g1, g2 or g3 not selected)
Signaling switch at second auxiliary release S23 (only when f2 not selected, required if g1, g2, g3 or g4 not selected)
Switch on ready-to-close signaling switch S20
Motor shutdown switch S12 (only if motorized operating mechanism selected)
Remote reset solenoid F7 (required if c2 not selected)
+1
+1
+1
+1
+1
0
0
+1
X7
X7
X7
X7
X7
X6
X5
X8
(max. 4)
0
+1
+1
+1
0
+1
0
+1
X6
X5
For ordering the auxiliary supply connectors see at "Accessories and spare parts, Guide frames for AC circuit breakers/non-automatic air circuit breakers", pages 45 to 50 and under "Accessories and spare parts, Auxiliary conductor connections, Auxiliary supply
connectors", page 56.
44
Breaking
capacity
Icu = Ics
kA
DT
PU
(UNIT,
Basic price SET, M)
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
1000
1600
... 66
... 66
3WL9211-1AA@@-@@A1
3WL9211-2AA@@-@@A1
1
1
1 unit
1 unit
103
103
25.000
25.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3AA@@-@@A1
3WL9212-4AA@@-@@A1
3WL9212-5AA@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
31.000
39.000
45.000
III
4000
... 100
3WL9213-6AA@@-@@A1
1 unit
103
60.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1AB@@-@@A1
3WL9211-2AB@@-@@A1
3WL9211-3AB@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
25.000
25.000
25.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3AB@@-@@A1
3WL9212-4AB@@-@@A1
3WL9212-5AB@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
31.000
39.000
45.000
III
4000
... 100
3WL9213-6AB@@-@@A1
1 unit
103
60.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1AC@@-@@A1
3WL9211-2AC@@-@@A1
3WL9211-3AC@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
25.000
25.000
25.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3AC@@-@@A1
3WL9212-4AC@@-@@A1
3WL9212-5AC@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
31.000
39.000
45.000
III
4000
5000
4000
5000
... 100
... 100
... 150
... 150
3WL9213-6AC@@-@@A1
3WL9213-7AC@@-@@A1
3WL9213-6AC@@-@@C1
3WL9213-7AC@@-@@C1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
103
103
103
103
60.000
60.000
63.000
63.000
Additional
price
Options
Number of auxiliary
supply connectors
Without
None
1 connector
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors,
see table on page 44.
Type of auxiliary circuit
connections
Shutters
Without
None
Without
None
Option 1:
Connected position 1 CO,
test position 1 CO,
disconnected position 1 CO
Option 2:
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO
Without
None
With shutter,
Size I
2-part, lockable Size II
Size III
Additional price
1)
For 3WL circuit breakers size I from 630A to 2000A with high breaking
capacity H and 3WL circuit breakers size I with rated current In = 2000 A.
45
3WL9 21.-.....-....-Z
Additional
price
@@@
A 0 5
A 0 5
Size III, not necessary with circuit breakers with very high breaking
capacity
A 0 5
A 1 5
A 1 6
Size I
A 0 8
Size II
A 0 8
Size III
A 0 8
Notes
For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code,
see pages 38 to 43.
Additional price
1)
2)
46
Breaking capacity
Icu = Ics
kA
DT
PS*/
P.
unit
PG
Weight
per PU
approx.
kg
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1AD@@-@@A1
3WL9211-2AD@@-@@A1
3WL9211-3AD@@-@@A1
1 1 unit
1 1 unit
1 1 unit
103
103
103
25.000
25.000
25.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3AD@@-@@A1
3WL9212-4AD@@-@@A1
3WL9212-5AD@@-@@A1
1 1 unit
1 1 unit
1 1 unit
103
103
103
31.000
39.000
45.000
III
4000
5000
6300
4000
5000
6300
... 100
... 100
... 100
... 150
... 150
... 150
3WL9213-6AD@@-@@A1
3WL9213-7AD@@-@@A1
3WL9213-8AD@@-@@A1
3WL9213-6AD@@-@@C1
3WL9213-7AD@@-@@C1
3WL9213-8AD@@-@@C1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103
103
103
103
103
103
60.000
60.000
70.000
63.000
63.000
74.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1AE@@-@@A1
3WL9211-2AE@@-@@A1
3WL9211-3AE@@-@@A1
1 1 unit
1 1 unit
1 1 unit
103
103
103
25.000
25.000
25.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3AE@@-@@A1
3WL9212-4AE@@-@@A1
3WL9212-5AE@@-@@A1
1 1 unit
1 1 unit
1 1 unit
103
103
103
31.000
39.000
45.000
III
4000
... 100
3WL9213-6AE@@-@@A1
1 1 unit
103
60.000
Options
Add. price
None
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors, see table on page 44.
Type of auxiliary
Without
circuit connections With screw connection (SIGUT, standard)
With screwless connection method (tension spring)
Position signaling
switches
Shutters
None
Without
None
Without
None
With shutter,
Size I
2-part,
Size II
lockable
Size III
3WL9 21.-.....-....-Z
@@@
Additional
price
A 0 5
A 0 5
Size III, not necessary with circuit breakers with very high breaking capacity
A 0 5
A 1 5
A 1 6
Size I
A 0 8
Size II
A 0 8
Size III
A 0 8
Notes
For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code,
see pages 38 to 43.
Additional price
1)
For 3WL circuit breakers size I from 630A to 2000A with high breaking
capacity H and 3WL circuit breakers size I with rated current In = 2000 A.
2)
3)
47
Breaking
capacity
Icu = Ics
kA
DT
PU
(UNIT,
Basic price SET, M)
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
1000
1600
... 66
... 66
3WL9211-1BA@@-@@A1
3WL9211-2BA@@-@@A1
1
1
1 unit
1 unit
103
103
30.000
30.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3BA@@-@@A1
3WL9212-4BA@@-@@A1
3WL9212-5BA@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
37.000
47.000
54.000
III
4000
... 100
3WL9213-6BA@@-@@A1
1 unit
103
84.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1BB@@-@@A1
3WL9211-2BB@@-@@A1
3WL9211-3BB@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
30.000
30.000
30.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3BB@@-@@A1
3WL9212-4BB@@-@@A1
3WL9212-5BB@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
37.000
47.000
54.000
III
4000
... 100
3WL9213-6BB@@-@@A1
1 unit
103
84.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1BC@@-@@A1
3WL9211-2BC@@-@@A1
3WL9211-3BC@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
30.000
30.000
30.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3BC@@-@@A1
3WL9212-4BC@@-@@A1
3WL9212-5BC@@-@@A1
1
1
1
1 unit
1 unit
1 unit
103
103
103
37.000
47.000
54.000
III
4000
5000
4000
5000
... 100
... 100
... 130
... 130
3WL9213-6BC@@-@@A1
3WL9213-7BC@@-@@A1
3WL9213-6BC@@-@@C1
3WL9213-7BC@@-@@C1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
103
103
103
103
84.000
84.000
87.000
87.000
Additional
price
Options
Number of auxiliary
supply connectors
Without
None
1 connector
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors,
see table on page 44.
Type of auxiliary circuit
connections
Shutters
Without
None
Without
None
Option 1:
Connected position 1 CO,
test position 1 CO,
disconnected position 1 CO
Option 2:
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO
Without
With shutter,
2-part, lockable
None
Size I
Size II
Size III
Additional price
1)
For 3WL circuit breakers size I from 630A to 2000A with high breaking
capacity H and 3WL circuit breakers size I with rated current In = 2000 A.
48
3WL9 21.-.....-....-Z
@@@
Additional
price
A 0 5
A 0 5
Size III, not necessary with circuit breakers with very high breaking
capacity
A 0 5
A 1 5
A 1 6
Size I
A 0 8
Size II
A 0 8
Size III
A 0 8
Notes
For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code,
see pages 38 to 43.
Additional price
1)
2)
49
Breaking capacity
Icu = Ics
kA
PU
PS*/
(UNIT, P. unit
SET,
Basic price
M)
per PU
Article No.
PG
Weight
per PU
approx.
kg
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1BD@@-@@A1
3WL9211-2BD@@-@@A1
3WL9211-3BD@@-@@A1
1 1 unit 103
1 1 unit 103
1 1 unit 103
30.000
30.000
30.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3BD@@-@@A1
3WL9212-4BD@@-@@A1
3WL9212-5BD@@-@@A1
1 1 unit 103
1 1 unit 103
1 1 unit 103
37.000
47.000
54.000
III
4000
5000
6300
4000
5000
6300
... 100
... 100
... 100
... 130
... 130
... 130
3WL9213-6BD@@-@@A1
3WL9213-7BD@@-@@A1
3WL9213-8BD@@-@@A1
3WL9213-6BD@@-@@C1
3WL9213-7BD@@-@@C1
3WL9213-8BD@@-@@C1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
103 84.000
103 84.000
103 119.000
103 88.000
103 88.000
103 124.000
1000
1600
20001)
... 66
... 66
... 85
3WL9211-1BE@@-@@A1
3WL9211-2BE@@-@@A1
3WL9211-3BE@@-@@A1
1 1 unit 103
1 1 unit 103
1 1 unit 103
30.000
30.000
30.000
II
2000
2500
3200
... 100
... 100
... 100
3WL9212-3BE@@-@@A1
3WL9212-4BE@@-@@A1
3WL9212-5BE@@-@@A1
1 1 unit 103
1 1 unit 103
1 1 unit 103
37.000
47.000
54.000
III
4000
... 100
3WL9213-6BE@@-@@A1
1 1 unit 103
84.000
Additional
price
Options
Number of auxiliary Without
supply connectors 1 connector
None
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors, see table on page 44.
Type of auxiliary
Without
circuit connections With screw connection (SIGUT, standard)
With screwless connection method (tension spring)
Position signaling
switches
Shutters
None
Without
None
Without
With shutter, 2-part,
lockable
None
Size I
Size II
Size III
3WL9 21.-.....-....-Z
@@@
Additional
price
A 0 5
A 0 5
Size III, not necessary with circuit breakers with very high breaking capacity
A 0 5
A 1 5
A 1 6
Size I
A 0 8
Size II
A 0 8
Size III
A 0 8
Notes
For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code,
see pages 38 to 43.
Additional price
1) For 3WL circuit breakers size I from 630A to 2000A with high breaking
capacity H and 3WL circuit breakers size I with rated current In = 2000 A.
50
2)
3)
DT Article No.
Price Equivalent US
Quickship
per PU catalog no. for
items (in limitQuickship items ed quantity).
NSE0_01610b
3WL931.-.AA.0-0AA1
Contact factory
for availability
Type
With protection
function
Measurement
function
ETU15B
LI
Without
3WL9311-5AA00-0AA2
ETU25B
LSI
Without
3WL9312-5AA00-0AA2
ETU27B
LSING
Without
3WL9312-7AA00-0AA2
ETU45B
(without display)
LSIN(G)
Without
With measurement
function Plus
3WL9314-5AA00-0AA2
3WL9314-5AA20-0AA2
ETU76B
LSIN(G)
Without
With measurement
function Plus
3WL9317-6AA00-0AA2
3WL9317-6AA20-0AA2
250
315
400
500
3WL9111-0AA51-0AA0
3WL9111-0AA52-0AA0
3WL9111-0AA53-0AA0
3WL9111-0AA54-0AA0
630
800
1000
3WL9111-0AA55-0AA0
3WL9111-0AA56-0AA0
3WL9111-0AA57-0AA0
I, II, III
1250
1600
2000
3WL9111-0AA58-0AA0
3WL9111-0AA61-0AA0
3WL9111-0AA62-0AA0
II, III
2500
3200
4000
3WL9111-0AA63-0AA0
3WL9111-0AA64-0AA0
3WL9111-0AA65-0AA0
III
5000
6300
3WL9111-0AA66-0AA0
3WL9111-0AA67-0AA0
3WL9111-0AT53-0AA0
3WL9111-0AT56-0AA0
Displays
For ETU45B
4-line
3WL9111-0AT81-0AA0
Rating plugs2)
n
Size
= 3 2 0 0 A
I, II
N S E 0 _ 0 0 9 9 2 b
3WL9111-0AA64-0AA0
G F M
5 1
g T R IP
A L A R M
A L A R M
T R IP
C
O F F
J g (s )
.5
B
D
.4
.3
.2
.1
A T 4 5 B
1 2 Jg
.1
.2
.3
Ground-fault modules3)
Versions
.4
.5
N S E 0 _ 0 1 0 2 7 a
3WL9111-0AT53-0AA0
WLLCD48
N S E 0 _ 0 1 6 0 9
3WL9111-0AT81-0AA0
Internal current transformers for N conductor
Including wiring kit
ETU Release 2
Size
--
I
II
III
3WL9111-0AA11-0AA0
3WL9111-0AA12-0AA0
3WL9111-0AA13-0AA0
3WL9111-0AA2.-0AA0
I
II
III
3WL9111-0AA14-0AA0
3WL9111-0AA15-0AA0
3WL9111-0AA16-0AA0
N S E 0 _ 0 0 9 9 0 a
3WL9111-0AA3.-0AA0
Size
--
I
II
III
3WL9111-0AA21-0AA0
3WL9111-0AA22-0AA0
3WL9111-0AA23-0AA0
I
II
III
3WL9111-0AA31-0AA0
3WL9111-0AA32-0AA0
3WL9111-0AA33-0AA0
WLNCT2
WLNCT3
EMC filters
Common-mode interference suppressor filters
(e.g. in IT networks, caused by frequency converters)
Insertion loss (asymm.) in the range 40 kHz to 10 MHz >40 dB.
Versions
Not for ETU Release 2
Only for ETU Release 2
1)
2)
With the rating plug selected, the maximum rated current In max of the
circuit breaker must not be exceeded. The following applies In In max.
3WL9111-0AK32-0AA0
3WL9111-0AK34-0AA0
3)
For direct measurement of the ground-fault current, e.g. in the neutral point
of the transformer, a 1,200 A/1 A current transformer, class 1, is required.
The internal load of the 3WL circuit breaker is 0.11 m. If the ground-fault
current is to be determined using the vectorial sum of the phases, a transformer must be installed in the neutral conductor.
51
DT Article No.
Price Equivalent US
Quickship
per PU catalog no. for items (in limitQuickship items ed quantity).
Contact factory
for availability
ETU25B
3WL9111-0AT45-0AA0
3WL9111-0AT46-0AA0
3WL9111-0AK21-0AA0
WLTUSC55
WLTUSC76
1)
Note
Automatic reset of the reclosing lockout
3WL9111-0AK21-0AA0 also needed.
Versions
N S E 0 _ 0 0 9 9 9 a
3WL9111-0AK0.-0AA0
24 V DC
48 V DC
120 V AC/125 V DC
208-250 V AC/208-250 V DC
3WL9111-0AK03-0AA0
3WL9111-0AK04-0AA0
3WL9111-0AK05-0AA0
3WL9111-0AK06-0AA0
3WL9111-0AK30-0AA0
3WL9111-0AK31-0AA0
3WL9111-0AK33-0AA0
WLRSET24
WLRSET48
WLRSET120
WLRSET240
Locking devices
Interlocking set for mechanical ON/OFF
consisting of 2 transparent covers each for sealing
or for attaching padlocks4),
Cover with 6.35 mm hole (for tool actuation)
Lock mount for lock for key operation
NSE00980
Versions
3WL9111-0BA22-0AA0
Without lock
Made by CES
Made by IKON
3WL9111-0BA21-0AA0
3WL9111-0BA22-0AA0
3WL9111-0BA24-0AA0
WLLKKT
3WL9111-0BA31-0AA0
3WL9111-0BA33-0AA0
3WL9111-0BA34-0AA0
3WL9111-0BA35-0AA0
3WL9111-0BA36-0AA0
3WL9111-0BA38-0AA0
3WL9111-0BA41-0AA0
WLLKOFFKRK
3WL9111-0BA31-0AA0
NSE0_00982
3WL9111-0BA53-0AA0
WLLKNP
Versions
Made by CES
Made by IKON
Made by KIRK-Key3)
Made by Ronis
Made by Profalux
1)
52
3WL9111-0BA51-0AA0
3WL9111-0BA53-0AA0
3WL9111-0BA57-0AA0
3WL9111-0BA58-0AA0
3WL9111-0BA50-0AA0
3)
4)
WLDLPR
DT Article No.
3WL9111-0BA71-0AA0
WLHANDLC
3WL9111-0BA73-0AA0
3WL9111-0BA75-0AA0
3WL9111-0BA76-0AA0
3WL9111-0BA77-0AA0
3WL9111-0BA80-0AA0
WLLKCLKRK
NSE00984
3WL9111-0BA71-0AA0
Locking devices to prevent movement of the withdrawable circuit breakers
Lock for mounting on the circuit breaker
Spare part for option S71, S75, S76, see "-Z" + order
code, page 41.
NSE0_00986
3WL9111-0BA76-0AA0
Versions
Made by CES
Made by IKON
Made by Profalux
Made by Ronis
Made by KIRK-Key2)
Interlocking systems
Made by CES
2 of the same keys for 3 circuit breakers
Locking device in OFF position
Lock in the operator panel
A maximum of 2 circuit breakers can be switched on
3WL9111-0BA43-0AA0
Locking mechanisms
NSE0_00987
3WL9111-0BA83-0AA0
Locking devices to prevent movement of the withdrawable circuit breakers in disconnected position
Consisting of Bowden wire and lock in the cabinet door
on the circuit breaker
Spare part for option R81, R85, R86, see "-Z" + order
code, page 41. Order code, page 41.
Versions
NSE0_00988
3WL9111-0BB12-0AA0
Made by CES
Made by IKON
Made by Profalux
Made by Ronis
Note
Not possible in combination with "Locking device to prevent opening of the cabinet door" (order code "R30") or
"Locking device to prevent movement with the cabinet
door open"
(order code "R50").
Locking devices to prevent opening of the cabinet
door in ON position
Fixed-mounted
Can be defeated
Spare part for option S30, see "-Z" + order code, page
41.
Locking devices to prevent opening of the cabinet
door
Guide frames
Can be defeated
Spare part for option R30, see "-Z" + order code, page 41.
Note
Not possible in combination with "Locking device to prevent movement of the withdrawable circuit breakers in
disconnected position" (order codes "R81", "R85" or
"R86").
Locking devices to prevent movement with the cabinet door open
Guide frames
Spare part for option R50, see "-Z" + order code, page 41.
3WL9111-0BA81-0AA0
3WL9111-0BA83-0AA0
3WL9111-0BA85-0AA0
3WL9111-0BA86-0AA0
3WL9111-0BB12-0AA0
WLLKOFFDRUL3
3WL9111-0BB13-0AA0
WLDRLC1
3WL9111-0BB15-0AA0
WLDRLC5UL
Note
Not possible in combination with "Locking device to prevent movement of the withdrawable circuit breakers in
disconnected position" (order codes "R81", "R85" or
"R86").
1)
2)
53
DT Article No.
Interlocks
Contact factory
Mutual mechanical interlocking
with 2000 mm Bowden wire
(one required for each circuit breaker)
Type
When
Spare part for
ordered
separately
Fixed-mounted circuit
breakers
--
3WL9111-0BB21-0AA0
WLNTLKF23
3WL9111-0BB24-0AA0
WLNTLK
3WL9111-0BB22-0AA0
WLNTLKC
3WL9111-0BB23-0AA0
WLNTLKB
--
3WL9111-0BB30-0AA0
WLNTLKB
3WL9112-8AH47-0AA0
WLMOC2
2000 mm
3,000 mm
4,500 mm
3WL9111-0BB45-0AA0
3WL9111-0BB46-0AA0
3WL9111-0BB47-0AA0
WLNTLWIRE2
WLNTLWIRE3
WLNTLWIRE4
3WL9111-0AT32-0AA0
Function testers
3WL9111-0AT44-0AA0
NSE0_00989
3WL9111-0BB21-0AA0
for availability
NSE0_01886
3WL9112-8HA47-0AA0
Bowden wires
Versions
Test devices
3WL9111-0BA14-0AA0
V DC
Note
Rated control supply voltage must match the rated control
supply voltage of the shunt release
Suitable also for 3VL and 3WN circuit breakers
54
DT Article No.
Price Equivalent US
per PU catalog no. for
Quickship items
Quickship
items (in limited quantity).
Contact factory
for availability
3WL9111-0AH01-0AA0
WLRTCS
Signaling switches1) 2)
1st or 2nd auxiliary release
Spare part for option C26 and C27, see "-Z" + order code,
page 39.
3WL9111-0AH02-0AA0
WLUVRC
3WL9111-0AH14-0AA0
3WL9111-0AH17-0AA0
3WL9111-0AH07-0AA0
3WL9111-0AH08-0AA0
N S E 0 _ 0 0 9 9 3 a
3WL9111-0AH01-0AA0
N S E 0 _ 0 0 9 9 4 b
WLSTC
3WL9111-0AH02-0AA0
WLBA
WLNUMCNT
N S E 0 _ 0 0 9 9 5 a
3WL9111-0AH07-0AA0
3WL9111-0AH12-0AA0
Versions
1st block (3 CO contacts)
2nd block (6 CO contacts)
3WL9111-0AH11-0AA0
3WL9111-0AH12-0AA0
WLGSGSW111
WLGSGSW321
3WL9111-0AJ02-0AA0
3WL9111-0AJ03-0AA0
3WL9111-0AJ05-0AA0
WLLECS
3WL9111-0AJ06-0AA0
WLMCOSW
EMERGENCY-STOP pushbuttons
Mushroom pushbutton instead of the mechanical
OFF pushbutton
Spare part for option S24, see "-Z" + order code, page 39.
3WL9111-0BA72-0AA0
WLEPEN
Electrical ON buttons1)5)
Button + wiring2)
For operator panel
Spare part for option C11 and C12, see "-Z" + order code,
page 39
N S E 0
0 0 9 9 7 a
3WL9111-0AJ0.-0AA0
Versions
With sealing cap C11
With CES C12 assembly kit
With IKON assembly kit
Note
Possible only for circuit breakers with closing coil.
NSE00985
3WL9111-0BA72-0AA0
1)
Not possible with communications interface option, order code "F02" or "F12".
4)
2)
5)
6)
3)
55
DT Article No.
Price Equivalent US
per PU catalog no. for
Quickship items
Quickship
items (in limited quantity).
Contact factory
for availability
WLCNMD
3WL9111-0AB02-0AA0
WLCNMDA
3WL9111-0AB10-0AA0
NSE0_00978
3WL9111-0AB01-0AA0
N S E 0 _ 0 1 2 6 8
Versions
Screw connection (SIGUT)
Screwless connection method (tension spring)
3WL9111-0AB03-0AA0
3WL9111-0AB04-0AA0
WLGAUXPLUGP
WLGAUXPLUGT
Coding kits
For fixed-mounted versions (X5 to X8)
3WL9111-0AB07-0AA0
WLCODEKITUL
3WL9111-0AB08-0AA0
WLGDSCN
3WL9111-0AB18-0AA0
WLGAUXPLUGL
3WL9111-0AB12-0AA0
WLGDAUXPLUG
N S E 0 _ 0 1 2 6 9
3WL9111-0AB03-0AA0
NSE00974
3WL9111-0AB04-0AA0
3WL9111-0AB07-0AA0
7 a
9 7
0 0
0 _
E
N S
NSE0_01586
3WL9111-0AB08-0AA0
3WL9111-0AB18-0AA0
Withdrawable versions:
56
or
Price Equivalent US
per PU catalog no. for
Quickship items
DT Article No.
Quickship
items (in limited quantity).
Contact factory
for availability
Auxiliary releases
Closing coils/shunt releases
Versions
Voltage
100 % OP
24 V DC
30 V DC
48 V DC
60 V DC
110 ... 125 V DC/110 ... 127 V AC
220 ... 250 V DC/208 ... 240 V AC
3WL9111-0AD01-0AA0
3WL9111-0AD02-0AA0
3WL9111-0AD03-0AA0
3WL9111-0AD04-0AA0
3WL9111-0AD05-0AA0
3WL9111-0AD06-0AA0
WLSTCD120
WLSTCD240
24 V DC
48 V DC
110 ... 125 V DC/110 ... 127 V AC
220 ... 250 V DC/208 ... 240 V AC
3WL9111-0AD11-0AA0
3WL9111-0AD12-0AA0
3WL9111-0AD13-0AA0
3WL9111-0AD14-0AA0
WLRCS24
WLRCS48
WLRCS120
WLRCS240
3WL9111-0AE01-0AA0
3WL9111-0AE02-0AA0
3WL9111-0AE03-0AA0
3WL9111-0AE07-0AA0
WLUV24
3WL9111-0AE04-0AA0
3WL9111-0AE05-0AA0
3WL9111-0AE06-0AA0
WLUV120
WLUV240
48 V DC
110 ... 125 V DC/110 ... 127 V AC
220 ... 250 V DC/208 ... 240 V AC
380 ... 415 V AC
3WL9111-0AE11-0AA0
3WL9111-0AE12-0AA0
3WL9111-0AE13-0AA0
3WL9111-0AE14-0AA0
WLUVD48
WLUVD120
WLUVD240
3WL9111-0AF01-0AA0
3WL9111-0AF02-0AA0
3WL9111-0AF03-0AA0
3WL9111-0AF04-0AA0
WLELCMTR24
WLELCMTR48
WLELCMTR120
WLELCMTR240
3WL9111-0AG01-0AA0
3WL9111-0AG02-0AA0
3WL9111-0AG03-0AA0
WLAS4
3WL9111-0AD06-0AA0
5%
OP1)
WLSTCD24
WLSTCD48
Undervoltage releases
Versions
Instantaneous
NSE01001
3WL9111-0AE0.-0AA0
Delayed
Voltage
24 V DC
30 V DC
48 V DC
60 V DC
WLUV48
NSE01002
3WL9111-0AE1.-0AA0
Operating mechanisms
Motorized operating mechanisms2)
Versions
24 ... 30 V DC
48 ... 60 V DC
110 ... 125 V DC/110 ... 127 V AC
220 ... 250 V DC/208 ... 240 V AC
N S E 0 _ 0 1 0 0 3 a
3WL9111-0AF0.-0AA0
Auxiliary contacts
Auxiliary switch blocks
Versions
2 NO contacts + 2 NC contacts
2 NO contacts
1 NO contact + 1 NC contact
NSE0_01004
3WL9111-0AG03-0AA0
1)
2)
57
DT Article No.
Price Equivalent US
per PU catalog no. for
Quickship items
Quickship
items (in limited quantity).
Contact factory
for availability
3WL9111-0AP01-0AA0
WLDSF
Protective covers
IP55
3WL9111-0AP02-0AA0
Notes
Cannot be used in conjunction with door sealing
frames
Hood removable and can be opened on both
sides
NSE0_01028a
3WL9111-0AP02-0AA0
Shutters
Spare part for option R21, see "-Z" + order code,
page 40.
Number of poles
Size
3-pole
I
II
III
3WL9111-0AP04-0AA0
3WL9111-0AP06-0AA0
3WL9111-0AP07-0AA0
4-pole
I
II
III
3WL9111-0AP08-0AA0
3WL9111-0AP11-0AA0
3WL9111-0AP12-0AA0
NSE0_01006
3WL9111-0AP0.-0AA0
Arc chutes
NSE0_01007
Arc chutes
Versions
Size
690 V
I
II
III
3WL9111-0AS01-0AA0
3WL9111-0AS02-0AA0
3WL9111-0AS03-0AA0
1000 V / 1150 V
II
III
3WL9111-0AS05-0AA0
3WL9111-0AS06-0AA0
3WL9111-0AS0.-0AA0
Arc chute covers1)
Parts kit for guide frame
Spare part for option R10, see "-Z" + order code,
page 40.
NSE0_01008
Number of poles
Size
3-pole
I
II
III
3WL9111-0AS32-0AA0
3WL9111-0AS36-0AA0
3WL9111-0AS38-0AA0
4-pole
I
II
III
3WL9111-0AS42-0AA0
3WL9111-0AS44-0AA0
3WL9111-0AS46-0AA0
3WL9111-0AS3.-0AA0
3WL9111-0AR12-0AA0
3WL9111-0AR13-0AA0
NSE0_01009
3WL9111-0AR12-0AA0
3WL9111-0AR13-0AA0
1)
58
Price Equivalent US
per PU catalog no. for
Quickship
items
DT Article No.
Quickship
items (in limited quantity).
Contact factory
for availability
Grounding connection
Grounding connection between the guide frame
and the withdrawable circuit breaker
For 30 kA ground short-circuit current1)
Contacting modules for guide frame
NSE0 01018a
3WL9111-0BA02-0AA0
Versions
Size I and II2)
Size III
3WL9111-0BA01-0AA0
3WL9111-0BA02-0AA0
WLEF2
Number of poles
Size
3-pole
I
II2)
III
3WL9111-0BA05-0AA0
3WL9111-0BA06-0AA0
3WL9111-0BA07-0AA0
4-pole
I
II2)
III
3WL9111-0BA08-0AA0
3WL9111-0BA04-0AA0
3WL9111-0BA10-0AA0
3WL9111-0BA07-0AA0
Support brackets
3WL9111-0BB50-0AA0
NSE-01022
Support brackets
For mounting fixed-mounted circuit breakers on
vertical plane
Only for sizes I and II (1 set = 2 units)
3WL9111-0BB50-0AA0
CubicleBUS modules3)6)
Digital output modules with rotary coding switch,
relay outputs
3WL9111-0AT26-0AA0
WLDGNCUB
3WL9111-0AT20-0AA0
WLRLYCCUB
3WL9111-0AT27-0AA0
WLRLYCUB
3WL9111-0AT23-0AA0
WLANLGCUB
3WL9111-0AT21-0AA0
WLZSIMD
N S E 0 _ 0 1 0 2 3 a
3WL9111-0AT23-0AA0
Parameterization systems6)
N S E 0 _ 0 1 0 2 4 a
BDA Plus4)5)
Parameterization, operation, monitoring and
diagnostics of 3WL air circuit breakers using
the local interface
Breaker Data Adapter, connection cable to the
3WL air circuit breaker and to the programming
device (e.g. notebook)
Can be run with Internet Explorer
with JAVA2 VM 1.4.0-01 and higher
With Ethernet interface for connection to
Ethernet/Intranet/Internet
3WL9111-0AT33-0AA0
3WL9111-0BC21-0AA0
3WL9111-0AT28-0AA0
1)
2)
3)
4)
5)
6)
WLBDAPMNT
59
DT Article No.
Price Equivalent US
per PU catalog no. for
Quickship items
Quickship
items (in limited quantity).
Contact
factory for
availability
3WL9111-0BC04-0AA0
3WL9111-0BC02-0AA0
3WL9111-0BC03-0AA0
3WL9111-0BC05-0AA0
WLCBUSCABLE02
WLCBUSCABLE1
WLCBUSCABLE2
3WL9111-0BB68-0AA0
3WL9111-0AT12-0AA0
WLCM15RET
3WL9111-0AT15-0AA0
WLCM16MD
3WL9111-0AT17-0AA0
3WL9111-0AT18-0AA0
3WL9111-0AT16-0AA0
3WL9111-0AT04-0AA0
Device
PROFIBUS DP
CubicleBus
NSE-01025
3WL9111-0AT15-0AA0
1)
2)
3)
60
WLBSS
DT Article No.
Rated current In
Up to 1000 A
1250 A to 1600 A
3WL9111-0AL01-0AA0
3WL9111-0AL02-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AL03-0AA0
3WL9111-0AL04-0AA0
3WL9111-0AL05-0AA0
III
Up to 4000 A
3WL9111-0AL06-0AA0
NSE-01010
3WL9111-0AL56-0AA0
Rated current In
Up to 1000 A
1250 A to 1600 A
3WL9111-0AL51-0AA0
3WL9111-0AL52-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AL53-0AA0
3WL9111-0AL54-0AA0
3WL9111-0AL55-0AA0
III
Up to 4000 A
3WL9111-0AL56-0AA0
NSE-01011
3WL9111-0AL64-0AA0
Size
Rated current In
Up to 1000 A 1)
1250 A to 2000 A
3WL9111-0AL07-0AA0
3WL9111-0AL08-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AL11-0AA0
3WL9111-0AL12-0AA0
3WL9111-0AL13-0AA0
III
Up to 4000 A
3WL9111-0AL14-0AA0
Rated current In
Up to 1000 A 1)
1250 A to 2000 A
3WL9111-0AL57-0AA0
3WL9111-0AL58-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AL61-0AA0
3WL9111-0AL62-0AA0
3WL9111-0AL63-0AA0
III
Up to 4000 A
3WL9111-0AL64-0AA0
Rated current In
I2)
Up to 2000 A
3WL9111-0AM01-0AA0
II3)
Up to 3200 A
3WL9111-0AM02-0AA0
III
Up to 6300 A
3WL9111-0AM03-0AA0
3WL9111-0AM03-0AA0
1)
2)
3)
61
DT Article No.
Rated current In
Up to 1000 A
1250 A to 1600 A
3WL9111-0AN01-0AA0
3WL9111-0AN02-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AN03-0AA0
3WL9111-0AN04-0AA0
3WL9111-0AN05-0AA0
III
Up to 4000 A
3WL9111-0AN06-0AA0
NSE-01013
3WL9111-0AN06-0AA0
NSE-01014
Size
Rated current In
Up to 1000 A 2)
1250 A to 2000 A
3WL9111-0AN07-0AA0
3WL9111-0AN08-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AN11-0AA0
3WL9111-0AN12-0AA0
3WL9111-0AN13-0AA0
III
Up to 4000 A
3WL9111-0AN14-0AA0
3WL9111-0AN14-0AA0
Size
I
II
III
3WL9111-0AN41-0AA0
3WL9111-0AN42-0AA0
3WL9111-0AN43-0AA0
I
II
III
3WL9111-0AN44-0AA0
3WL9111-0AN45-0AA0
3WL9111-0AN46-0AA0
NSE-01017
3WL9111-0AN41-0AA0
Rear vertical main connections
NSE-01015
Size
Rated current In
Up to 1000 A 2)
1250 A to 2000 A
3WL9111-0AN15-0AA0
3WL9111-0AN16-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AN17-0AA0
3WL9111-0AN18-0AA0
3WL9111-0AN21-0AA0
III
Up to 5000 A
3WL9111-0AN22-0AA0
3WL9111-0AN23-0AA0
Up to 6300 A, at top,
4 busbar connection pieces
for 4-pole circuit breakers
3WL9111-0AN20-0AA0
Up to 6300 A, at bottom,
4 busbar connection
pieces for 4-pole circuit breakers
3WL9111-0AN10-0AA0
3WL9111-0AN23-0AA0
Rated current In
Up to 1000 A 2)
1250 A to 2000 A
3WL9111-0AN32-0AA0
3WL9111-0AN33-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AN34-0AA0
3WL9111-0AN35-0AA0
3WL9111-0AN36-0AA0
III
Up to 5000 A
3WL9111-0AN37-0AA0
NSE-01016
Connecting flange
3WL9111-0AN24-0AA0
Size
Rated current In
Up to 1000 A 2)
1250 A to 2000 A
3WL9111-0AN24-0AA0
3WL9111-0AN25-0AA0
II
Up to 2000 A
Up to 2500 A
Up to 3200 A
3WL9111-0AN26-0AA0
3WL9111-0AN27-0AA0
3WL9111-0AN28-0AA0
III
Up to 4000 A
3WL9111-0AN31-0AA0
1)
2)
62
DT Article No.
Contact factory
for availability
Conversion sets
Conversion set for converting fixed-mounted circuit
breakers into withdrawable circuit breakers
Guide frames and sliding contact modules must be
ordered separately.
Number of poles
Size
3-pole
3WL9111-0BC11-0AA0
II
3WL9111-0BC12-0AA0
III
3WL9111-0BC13-0AA0
3WL9111-0BC14-0AA0
II
3WL9111-0BC15-0AA0
III
3WL9111-0BC16-0AA0
4-pole
NSE-01021
Size
In max
Up to 1600 A
3WL9111-0AM90
L1Y1)
II
Up to 2500 A
3WL9111-0AM91
II
Up to 4000 A
III
Up to 6300 A
L1Y1)
3WL9111-0AM92
L1Y1)
3WL9111-0AM93
L1Y1)
Notes
The circuit breaker ID No. must be specified when
ordering
Specified for each connection (depending on the number of poles on the circuit breaker, order 3 or 4 units)
Article No. is automatically adapted to the circuit
breaker ID number
1)
Please specify the circuit breaker ID No. in plain text when ordering.
63
Size
DT Article No.
Rated current In
Size
3-pole
Up to 1600 A
Up to 3200 A
Up to 6300 A
I
II
III
3WL9111-0BD01-0AA0
3WL9111-0BD03-0AA0
3WL9111-0BD05-0AA0
4-pole
Up to 1600 A
Up to 3200 A
Up to 6300 A
I
II
III
3WL9111-0BD02-0AA0
3WL9111-0BD04-0AA0
3WL9111-0BD06-0AA0
NSE0_01112
NSE0_01119
NSE0_01113
L1 L2 L3
NSE0_01122a
L1 L2 L3
NSE0_01114
NSE0_01123a
NSE0_01115
64
L1 L2 L3
L1 L2 L3
NSE0_01121
NSE0_01116
L1 L2 L3
NSE0_01120
L1 L2 L3
NSE0_01117
NSE0_01118
Options
Structure of the Article No.
3WL1
Example
5th position:
Size
Size II
In max = 2000 A
8th position:
Breaking capacity
class
9th position:
10th position:
11thposition:
Number of poles
Three-pole
12th position:
Installation type
Fixed-mounted, main
connections on rear, vertical
13th position:
Operating
mechanisms
14th position:
15th position:
16th position:
Auxiliary switches
Offer processing
Selection and configuration
Order processing
Orders
Order confirmation
Processing of products for storage
Order processing in supply
locations
Supply and dispatch
Reporting and planning
Service and warranty
2 NO contacts + 2 NC contacts
Example
>
Communications interface
"Standard" + Breaker Status Sensor (BSS)
+ communication module COM15 for
connection to PROFIBUS DP
Documentation
Operating manual
Complete set
German/English
Article No.
3ZX18 12-0WL00-0AN1
PROFIBUS manual
Communication
English
Article No.
A5E0151353
MODBUS manual
Communication
English
Article No.
3ZX10 12-0WL10-1AC1
65
3-pole non-automatic
air circuit breakers
Article No.
DC
Price
per PU
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight per
PU approx.
kg
1000
2000
40001)
3WL1210-8@@32-@@@@
3WL1220-8@@32-@@@@
3WL1240-8@@32-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
56.000
56.000
64.000
3WL1210-8@@31-@@@@
3WL1220-8@@31-@@@@
3WL1240-8@@31-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
56.000
56.000
85.000
3WL1210-8@@33-@@@@
3WL1220-8@@33-@@@@
1
1
1 unit
1 unit
103
103
56.000
56.000
3WL1210-8@@34-@@@@
3WL1220-8@@34-@@@@
1
1
1 unit
1 unit
103
103
56.000
56.000
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight per
PU approx.
1000
2000
40001)
1000
2000
1000
2000
Options
Add. price
AA
None
1AA2
None
4-pole non-automatic
air circuit breakers
Article No.
DC
Price per PU
kg
1000
2000
40001)
3WL1210-8@@42-@@@@
3WL1220-8@@42-@@@@
3WL1240-8@@42-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
67.000
67.000
77.000
3WL1210-8@@41-@@@@
3WL1220-8@@41-@@@@
3WL1240-8@@41-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
75.000
75.000
103.000
3WL1210-8@@43-@@@@
3WL1220-8@@43-@@@@
1
1
1 unit
1 unit
103
103
67.000
67.000
3WL1210-8@@44-@@@@
3WL1220-8@@44-@@@@
1
1
1 unit
1 unit
103
103
67.000
67.000
1000
2000
40001)
1000
2000
1000
2000
Options
Add. price
AA
None
1AA2
None
Condition
Rated voltage
1000 V DC
Size
II
3WL12.0-8....-....-Z
@@@
Additional price
3-pole
4-pole
Rated current In
Up to 2000 A
A 0 5
Up to 4000 A
A 0 5
Note
For voltages over 600 V use the version for 1000 V DC rated voltage: Order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "-Z" and the corresponding order code,
see "3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC), IEC", "Options",
page 38 onwards.
An external overload and short-circuit protection device is available from the company "mat" for the
3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und Anlagentechnik
(for address see page 1/68).
Additional price
1)
66
2)
3-pole non-automatic
air circuit breakers
Article No.
DC
Price
per PU
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
kg
1000
2000
40001)
3WL1210-8@@35-@@@@
3WL1220-8@@35-@@@@
3WL1240-8@@35-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
60.000
60.000
68.000
3WL1210-8@@36-@@@@
3WL1220-8@@36-@@@@
3WL1240-8@@36-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
91.000
91.000
113.000
1000
2000
40001)
3WL1210-8@@37-@@@@
3WL1220-8@@37-@@@@
3WL1240-8@@37-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
91.000
91.000
121.000
1000
2000
40001)
3WL1210-8@@38-@@@@
3WL1220-8@@38-@@@@
3WL1240-8@@38-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
91.000
91.000
113.000
1000
2000
40001)
Additional
price
Options
Non-automatic
air circuit breakers2)
Operating mechanisms
AA
None
1AA2
None
Condition
Size
II4)
3WL12.0-8..3.-....-Z
Additional price
@@@
3-pole
Rated current
In
Up to 2000 A
A 0 5
Up to 4000 A
A 0 5
A 0 8
For voltages over 600 V use the version for 1000 V DC rated voltage: Order with "-Z" and order
code "A05".
All other accessory parts must be ordered by specifying "-Z" and the corresponding order code,
see "3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC), IEC",
"Options", page 38 onwards.
An external overload and short-circuit protection device is available from the company "mat" for
the 3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und Anlagentechnik
(for address see page 68).
Additional price
1)
2)
3)
4)
If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame.
67
4-pole non-automatic
air circuit breakers
Article No.
DC
Price
per PU
PU
(UNIT,
SET, M)
PS*/
P. unit
PG
Weight
per PU
approx.
kg
1000
2000
40001)
3WL1210-8@@45-@@@@
3WL1220-8@@45-@@@@
3WL1240-8@@45-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
75.000
75.000
82.000
3WL1210-8@@46-@@@@
3WL1220-8@@46-@@@@
3WL1240-8@@46-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
109.000
109.000
136.000
1000
2000
40001)
3WL1210-8@@47-@@@@
3WL1220-8@@47-@@@@
3WL1240-8@@47-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
109.000
109.000
146.000
1000
2000
40001)
3WL1210-8@@48-@@@@
3WL1220-8@@48-@@@@
3WL1240-8@@48-@@@@
1
1
1
1 unit
1 unit
1 unit
103
103
103
109.000
109.000
136.000
1000
2000
40001)
Additional
price
Options
Non-automatic
air circuit breakers2)
Operating mechanisms
AA
None
1AA2
None
Condition
Size
II4)
Additional price
3WL12.0-8..4.-....-Z
@@@
4-pole
Rated current
In
Up to 2000 A
A 0 5
Up to 4000 A
A 0 5
A 0 8
For voltages over 600 V use the version for 1000 V DC rated voltage: Order with "-Z" and order
code "A05".
All other accessory parts must be ordered by specifying "-Z" and the corresponding order code,
see "3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC), IEC",
"Options", page 38 onwards.
An external overload and short-circuit protection device is available from the company "mat" for
the 3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und Anlagentechnik5).
Additional price
1)
2)
3)
4)
If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame.
68
5)
DT
PU
(UNIT,
SET,
M)
Price
per PU
PS*/
P. unit
PG
Weight
per PU
approx.
kg
2000
3WL9212-3DA@@-@@A1
1 unit
103
31.000
3WL9212-3DB@@-@@A1
1 unit
103
31.000
3WL9212-3DC@@-@@A1
3WL9212-6DC@@-@@A1
1
1
1 unit
1 unit
103
103
31.000
60.000
3WL9212-3DD@@-@@A1
3WL9212-6DD@@-@@A1
1
1
1 unit
1 unit
103
103
31.000
60.000
3WL9212-3DE@@-@@A1
3WL9212-6DE@@-@@A1
1
1
1 unit
1 unit
103
103
31.000
60.000
2000
2000
4000
2000
4000
2000
4000
Additional
price
3-pole
Options
No. of aux. supply connectors
Without
None
1 connector
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors,
see table on page 44.
Type of aux. circuit connections Without
Shutters
None
Without
None
Option 1:
Connected position 1 CO,
test position 1 CO,
disconnected position 1 CO
Option 2:
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO
Without
None
3WL9 212-.....-..A1-Z
Additional
price
@@@
A 0 5
A 0 8
1)
69
DT
PU
(UNIT,
Price SET, M)
per PU
Article No.
PS*/
P. unit
PG
Weight
per PU
approx.
kg
2000
3WL9212-3EA@@-@@A1
1 unit
103
37.000
3WL9212-3EB@@-@@A1
1 unit
103
37.000
3WL9212-3EC@@-@@A1
3WL9212-6EC@@-@@A1
1
1
1 unit
1 unit
103
103
37.000
84.000
3WL9212-3ED@@-@@A1
3WL9212-6ED@@-@@A1
1
1
1 unit
1 unit
103
103
37.000
84.000
3WL9212-3EE@@-@@A1
3WL9212-6EE@@-@@A1
1
1
1 unit
1 unit
103
103
37.000
84.000
2000
2000
4000
2000
4000
2000
4000
Additional
price
4-pole
Options
No. of aux. supply connectors
Without
None
1 connector
2 connectors
3 connectors
4 connectors
Note
For required number of auxiliary supply connectors, see table on
page 44.
Type of auxiliary circuit
connections
Shutters
Without
None
Without
None
Option 1:
Connected position 1 CO,
test position 1 CO,
disconnected position 1 CO
Option 2:
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO
Without
None
3WL9 212-.....-..A1-Z
Additional
price
@@@
A 0 5
A 0 8
70
www.usa.siemens.com/3WLIEC