Dih 52
Dih 52
Dih 52
Applications
Process engineering
Plant construction
General industrial applications
Oil and gas industry
Special features
Description
The DIH series field indicators are 4 ... 20 mA current loop
indicators which can, in addition, offer a superimposed
HART communication between the connected transmitter
and the control room. Thus the indication range and units
are automatically adopted dependent on the settings of
the connected HART transmitter.
Common units for temperature and pressure are already
saved ex works. An additional User unit can be
programmed optionally.
With this field indicator it is possible to display range alarms
as well as MIN and MAX values. Error-current signals from
the connected transmitters are also detected and displayed.
The indicator can be used in conjunction with any 4 ... 20 mA
transmitter.
Page 1 of 6
Specifications
Model DIH50
Display
Principle
Measured value
Bar graph
Info line
Status indicators
Indication range
Measuring rate
Accuracy
Temperature coefficient
Input signal
Output signal
Permissible current carrying capacity
Voltage drop
HART functionality
Access control
Automatically set parameters
Available commands
Identified commands
Multidrop
Electrical connection
Signal input
Signal output
Operating conditions
Ambient temperature
Functional area of the display
Storage temperature
Humidity
Vibration resistance
Shock resistance
CE conformity
EMC directive
Model DIH52
Secondary master
Unit, measuring range start/end, format, zero
point, span, damping, polling address
Generic mode: 0, 1, 6, 15, 34, 35, 36, 37, 44
Measured values are automatically taken from
the HART digital data and displayed
Field case
Material
Dimensions
Material
Polycarbonate
Ingress protection
Weight
IP 20
Colour
Cable bushings
Ingress protection
Weight
Dimensions
Page 2 of 6
approx. 80 g
see drawing
Approvals
DIH50-S, DIH52-S
(field indicator)
DIH50-Z, DIH52-Z
(HART loop module)
DIH50-B
(HART loop module)
Safety-related
maximum values
for current loop
( connections)
without
Ambient/storage
temperature (in accordance
with the relevant
temperature classes)
-20 ... +85 C
without
II 1G
Ex ia IIC T4/T5/T6 Ga
II (1) 2G Ex ia IIC T4/T5/T6 (Ga) Gb
Ui < 29 V
Ii < 100 mA
Pi < 660 mW
Ci = 12 nF
-40 ... +40 C (Pi = 660 mW) Li = 2.2 H
DIH50-F, DIH52-F
(field indicator)
14.5 ... 42 V
14.5 ... 42 V
14.5 ... 29 V
Ui = 29 V
(Vmax < 29 V)
Ii = 100 mA
(Imax < 100 mA)
Pi = 660 mW
(Pmax < 660 mW)
Power
supply UB
(DC)
Ci = 12 nF
Li = 2.2 H
Ui < 29 V
(27.5 V/26 V)
Ii < 100 mA
(115 mA/131 mA)
14.5 ... 30 V
II 2G
II 2G
DIH50-I, DIH52-I
(field indicator)
Ex d IIC T6/T5/T4 Gb
Ex db IIC T6/T5/T4
Ex d IIC T6/T5/T4 Gb
Ex db IIC T6/T5/T4
-40 ... +85 C at T4
Intrinsically safe equipment 1)
BVS 10 ATEX E 016 X
-40 ... +75 C at T5
IECEx BVS 10.0037X Ex ia [ia Ga] -40 ... +60 C at T6
UM = 30 V
PM = 2 W
Ui 29 V
Ii 100 mA
Pi 680 mW
Ci = 12 nF
-40 ... +40 C (Pi = 680 mW) Li = 2.2 H
-40 ... +70 C (Pi = 650 mW)
14.5 ... 29 V
Electrical connection
Non-hazardous area
Hazardous area
DIH50, DIH52
Voltage supply
spring-loaded
push terminals
Transmitter
red
black
Load
Legend:
Voltage supply
2-wire connection
Load
Dimensions in mm
1920741.01
1556707.01
User interface
Status data
Unit and info line
Measured value
Bar graph
Operating keys
Accessories
Model
Special features
Order no.
Model 010031
HART modem for USB interface, specifically designed for use with modern notebooks 11025166
Model 010001
7957522
Model 010041
11364254
FC475HP1EKLUGMT
HART
FC475FP1EKLUGMT
MFC5150
HART protocol, universal voltage supply, cable set with 250 resistor,
with explosion protection
on request
on request
on request
14026893
CE conformity
EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and
interference immunity (industrial application)
ATEX directive
94/9/EC
Approvals
IECEx, international certification for the Ex area
FM, ignition protection type i - intrinsic safety, USA
CSA, ignition protection type i - intrinsic safety, Canada
EAC, import certificate, Russia
GOST, metrology/measurement technology, Russia
Certificates (option)
2.2 test report
3.1 inspection certificate
DKD/DAkkS calibration certificate
Ordering information
Model / Indicator module / Explosion protection / Case material / Cable bushings / Threaded connection for cable bushing /
Certificates / Options
Page 6 of 6
11/2014 EN
2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.