Giovanni Papio FABE 3150-System Dynamics and Electricity Dr. Lichtensteiger 23 March 2017
Giovanni Papio FABE 3150-System Dynamics and Electricity Dr. Lichtensteiger 23 March 2017
10 kilohm resistor
20
15
f(x)==19.96x + 0
R
10
0
-2 -1.5 -1 -0.5 0 0.5 1 1.5 2
-5
-10
-15
-20
As seen with this R2 value, the degree of linearity is very accurate, as R 2 is equal to
1. The measured value of the test resistor, R1 was 9.95 kOhms, and the slope was
9.959 kOhms. This percent error was only 0.090%, and our tested values were
extremely linear.
Problem 3
vin v1 v2 KVL
-15 4.067 11.01 0.078
1
-10 2.788 7.291 0.079
-4.963 1.452 3.131 -0.38
0.002 0 0 0.002
4.992 -1.297 -3.191 0.504
10.01 -2.121 -7.237 0.652
14.88 -3.997 - -0.106
10.98
9
These values are all fairly close to zero. However, the Kirchhoffs Voltage Law isnt
quite zero due to minor errors, including human measurement error, calibration
error, and other errors involved with the instrumentation.
Problem 4
Refer to Lab Packet for calculations.
The equivalent Resistance using measured values was 46.0 Ohms. This led to the
voltage being 0.069 V calculated from the measured resistances. However, when V 0
was measured itself, it had a value of 0.067V. These values are very close to each
other.
Problem 5