GENERAL NOTES
DYNASET hydraulic magnet generator of HMG-range, designed for an installation to material handling machines
(hydraulic excavators, heavy trucks with hydraulic cranes), is compact and complete power source for ferrous
metal handling magnet. The only power source is a hydraulic system to provide generator with required
hydraulic fluid flow at demanded pressure.
DYNASET hydraulic magnet generator transforms hydraulic power into a high quality electricity, which is used
for energising metal handling magnet. HMG-PCI units are provided with an external electric control.
An automatic demagnetisation ensures fast disengagement of a picked and moved metal off from a magnet.
DYNASET HMG-generators operates with all 220 VDC metal handling magnets upon condition that magnets
coil inductance is 0 ... 20 H.
CONSTRUCTION
DYNASET hydraulic magnet generator is comprised of hydraulic synchronous generator and electric control
unit which includes a rectifier block and operation control automatics. The power-to-weight ratio of DYNASET
hydraulic magnet generator is excellent due to modern mono-bearing construction when the other end of
rotors shaft is supported by hydraulic motor. (Generators over 15 kVA are bi-bearing units).
The unit has an automatic rotation speed control valve with ports for pressure and return lines.
Units rotor, connected to the hydraulic motors shaft, is provided with an excitation windings.
Electric power is taken from stator windings. Auxiliary winding of voltage control system is located in generators
stator as well. Windings are isolated from units body and their insulation class is H.
Protection class of DYNASET hydraulic magnet generator in standard execution complies with specifications
IP23, electric control unit meets requirements of IP44. Units with (higher ?)protection class IP 54 are available
by request.
AC-auxiliary electricity is optional (standard in HMG 3,0 kW).
Automatic circuit breakers protect unit from overload.
Voltage control of HMG 3 kW is effected with a capacitor circuit, connected to an auxiliary winding.
Voltage control keeps the voltage constant through the whole load range with accuracy of ± 6%.
Performance speed of voltage control is less than 0,1 sec.
All other HMG-units are equipped either with a compound or electronic voltage regulator.
Compound regulator is connected to the auxiliary winding and maintains the output voltage constant
through the entire load range with accuracy of ± 5%. Compound regulator sets the excitation current
according to electric load of each phase with its separate current windings individually. Each phase can
be loaded up to maximum current deliberately.
Performance speed of a compound voltage controls is less than 0,1 sec.
Electronic voltage regulator is connected to the stators and separate excitation generators windings
and achieves an accuracy of ± 3%.
Electronic voltage regulator constantly compares output voltage to the pre-adjusted reference value
and sets the excitation current according the load.
Performance speed of an electronic voltage controls is less than 0,1 sec.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 2 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
Q m i n = Q n o m + 1...5 l/min
Qmin - minimal flow
Qnom - nominal flow Q, l/min
0 Qmin Qmax HYDRAULIC
FLUID FLOW
CLASSIFICATION
DYNASET hydraulic generators are manufactured in conformity with the 98/37, 73/23, 89/336 CEE directives
and their amendments. They are also manufactured in compliance with the following regulations: CEI 2-3,
EN 60034-1, IEC 34-1, VDE 0530, BS4999-5000, CAN/CSA-C22.2, NF 51.100 and N°14-95 - N°100-95.
By request DYNASET hydraulic generators can be equipped with a radio interference protection to meet
requirements of specifications MIL STD 461 A/B and VDE 0875 class N.
INSTALLATION
DYNASET hydraulic magnet generator works being integrated into an original hydraulic
P system of a material handling machine.
T Unit can be placed deliberately ensuring an easy access to the unit. Generator should
be positioned horisontally. Additionally, return line must be connected to a hydraulic oil
tank in the shortest possible way in order to keep return oil pressure under 5 bar.
Cooling capacity of hydraulic system, designed for continuous operation (an excavator),
is generally sufficient under proper installation of HMG-generator. An additional oil cooler
is required when HMG-unit is installed to a truck with and hydraulic hoist.
Ensure that the filtration capacity of a hydraulic system is sufficient.
To enable putting DYNASET generator into operation only pressure- (P) and return (T) lines are to be connected
to the hydraulic system.
Ensure that the hydraulic fluid flow is sufficient to run the unit, i.e. at least the minimal flow must be available.
At the hydraulic flow less that demanded nominal rate the generator will not work properly at all. If the
hydraulic flow is so excessive, that the automatic speed control valve is unable to handle it, the unit begins
to hunt. In the latter case the hydraulic flow is to be reduced either by replacing an existing hydraulic pump
with a suitable one or using flow limiter. DYNASET PRIORITY VALVE is recommended.
After having been connected to the hydraulic system, DYNASET hydraulic magnet generator is to be started
by directing the hydraulic flow to the units pressure port by means of control valve - manual or solenoid. Even
simple ball valve or three-way valve can be used.
To ensure DYNASETs proper operation, the hydraulic pressure must be set at least to the level, at which the
nominal power output is achieved (ref. to PARAMETERS). Lower pressure reduces output power. Maximum
hydraulic pressure is 250 bar (ref. to PARAMETERS). If the hydraulic system main pressure is higher, service
pressure relief valve must be used.
Ensure also that your machines hydraulic fluid cooling is working properly when DYNASET magnet generator
is in operation.
DYNASET HYDRAULIC GENERATORS ARE DESIGNED FOR EASY INTEGRATION INTO HYDRAULIC SYSTEM OF ANY TYPE:
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 3 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
The demanded hydraulic flow is to be ensured and controlled with a DYNASET PRESSURE COMPENSATED PRIORITY VALVE.
The demanded hydraulic flow is to be ensured and controlled with a DYNASET PRESSURE
COMPENSATED LOAD SENSING (LS) VALVE.
ALSO AVAILABLE for closed centre hydraulic systems with variable displacement pump:
DYNASET SOLENOID VALVE to the pressure line for remote starting.
SV 70 NC - 1/2 - 12 / 24 V max 70 l/min with LS -connection;
SV 150 NC 1 - 12 / 24 V max 150 l/min with LS -connection.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 4 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
...INSTALLATION
AUTOMATIC
ROTATION SPEED Installation with a standard pressure
CONTROL VALVE
compensated 3-way valve should be avoided in
T P order to close off potential waving in hydraulic
S system.
M
2 20 M
HMG 3 kW 5 x 2,5 mm 2 CABLE
HMG 6 kW 5 x 2,5 mm 2
HMG 3 kW 5 x 2,5 mm 2
HMG 10 kW 5 x 2,5 mm 2 HMG 6 kW 5 x 2,5 mm
6,0 mm 2
YELLOW-GREEN
BLUE
BROWN
2,5 mm 22
BLACK
BLACK
HMG 12 kW 5 x HMG 10 kW 5 x
HMG 15 kW 5 x 6,0 mm 2 HMG 12 kW 5 x 6,0 mm
HMG 3 kW 5 x 16A
HMG 20 kW 5 x 6,0 mm 2 HMG 15 kW 5 x 6,0 mm 2
HMG 6 kW 5 x 16A HMG 30 kW 5 x 6,0 mm 2 HMG 20 kW 5 x 6,0 mm 2
HMG 10 kW 5 x 16A HMG 30 kW 5 x 6,0 mm 2
HMG 12 kW 5 x 32A 5M
HMG 15 kW 5 x 32A
HMG 20 kW 5 x 63A SOCKET AND PLUG
HMG 30 kW 5 x 63A
HMG 3 kW 5 x 16A
HMG 6 kW 5 x 16A
HMG 10 kW 5 x 16A
HMG 12 kW 5 x 32A
HMG 15 kW 5 x 32A
HMG 20 kW 5 x 63A
HMG 30 kW 5 x 63A
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 5 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
Your DYNASET hydraulic magnet generator is tested and adjusted at factory, however is recommended
to check the DC voltage prior to taking the unit into operation.
1
Ensure that the generator is properly installed and connected to the hydraulic system of your carrier
machine and there are no hydraulic fluid leakages.
2
Start the engine of your carrier machine. Adjust the engine speed to the demanded level if necessary.
3
Start the generator with a ON/OFF switch and turn on the magnet.
4
Read generators voltmeter. Verify the voltage value with an multimeter from generators socket.
5.
If voltage reading is out of limits:
5.1
ensure whether the hydraulic fluid flow is on the demanded level.
5.2
make setting by adjusting the RPM-cartridge:
1 Loosen the checknut (1), make an adjustment (2) with adjusting screw
according to the readings of an instrument and then tighten the checknut.
2 NOTE !
When making adjustment, the hydraulic fluid should be at normal
operation temperature !
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 6 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
OPERATION
After ensuring the proper operation of the generator, plug magnets cable to generators socket.
Start machines engine.
Direct the hydraulic flow to a generator by opening a solenoid valve, when the control voltage 12/24V,
brought to the control unit, activates (ref. HMG CONTROL WIRING KIT on a previous page). Magnet is
ready for use when hydraulic flow achieves a minimal demanded level.
Generator rotates constantly the pressure line being open.
Magnets current is switched on by pressing magnets control push-button once for app. 1 sec, when
material is to be picked and moved. Magnetisation indicator light is ON.
Press the push-button sequently to cut-off magnets current (magnetisation indicator light is OFF) and
to turn on the reverse current, when a residual field discharges due to demagnetisation and all material
being kept by a magnet drops down. During a demagnetisation an indication light flashes once. Duration
of the second pressing affects the demagnetisation power. Keeping the push-button pressed down
magnets demagnetisation is being forced to ensure complete release of a material. Generally discharge
time is 2 - 3 sec subject to magnet.
After release of a material, magnet is returned to an iron picking point and the job continues in above
sequence.
Magnetisation and demagnetisation of a magnet is controlled by PCI-card, located in HMGs control unit.
Control is effected according to push-buttons impulses by means of contactors K1, K2 and K3, also
located in control units enclosure. Contactor status is indicated with LEDs found on a PCI-card.
12 / 24 V
DEMAGNETISATION BEGINS...
DELAY 0,5 - 3 s
CONTACTOR K1 DISENGAGED DELAY app. 0,2 s
CONTACTOR K3 DISENGAGED
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 7 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... OPERATION
Hydraulic pressure is being adjusted according to the magnets power demand, when the hydraulic fluid flow
is being kept constant.
Pressure p, bar
DYNASET hydraulic magnet generator produces high pmax
quality electric power within pressure range from pnom
idle run pressure to the maximum allowed value.
The nominal power output is achieved at pressure
value, which is noticeably less than the maximum
allowed operation pressure.
Refer to the attached diagram and technical
specifications.
Q (l/min) = const
pidle
P ( kW )
P kW
max
ATTN. !
Remove side screens (1) and air diffuser (3) to clean fan
compartment as well as rotor and stator.
Use blow gun with a REASONABLE Remove cover (2) to dust alternators electric components.
Having dusted/cleaned the generator, replace screens/covers
DELIBERATION to dust your equipment. and secure them with appropriate screws.
(Above picture for reference only - refer to the data pages
of specific HMG-model).
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 8 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... MAINTENANCE
Remove all oil deposits. Remove all unnecessary grease and oil from the unit. Accumulated grease
and oil can cause overheating and subsequent generator damage and may present a potential fire
hazard. Do not leave in the generator case or control box anything which does not belong to the assembly.
The tightness of lids and covers as well as of all screw joints must be inspected on a regular basis, for instance
at least once a week or more frequently, if a generator is exposed to a noticeable vibration.
Having carried a maintenance or cleaning, NEVER LEAVE ALTERNATORS COVER AND/OR ELECTRIC BOX COVER
UNREPLACED AND UNSECURED ! Condition of any seal/gasket must be inspected and defective parts replaced.
HYDRAULIC FLUIDS
Wide range of standard hydraulic fluids can be used with the DYNASET hydraulic equipment.
Subject to the operating temperature, following mineral hydraulic oils are recommended:
ISO VG 32S for oils operation temperature up to 70 °C;
ISO VG 46S for oils operation temperature up to 80 °C;
ISO VG 68S for oils operation temperature up to 90 °C.
Synthetic and bio-oils can be used as well if their viscosity characteristics and lubricating efficiency are
corresponding to above mineral oils. Automatic transmission fluids and even engine oils can be used, provided
that they are allowed to be used in hydraulic system of your carrier machine.
Prior to use special hydraulic fluids a with DYNASET equipment, please be kindly requested to contact nearest
DYNASET representative for an advice.
SAFETY
The generators output voltage is as high as 230/400 V. Operators and maintenance personnel must always
comply with local safety regulations and precautions in order to close out the possibility of damages and
accidents. Prior to detaching a magnet from a carrier, unplug it from a generators socket ! Capacitors of
control unit can discharge developing voltage over 200V even the equipment stands still.
The hydraulic system is usually pressurised up to 250 (420) bar. Follow all your local safety instructions related
to the high pressure hydraulics.
TECHNICAL CONDITION OF YOUR MACHINERY AND EQUIPMENT MUST BE SUBJECTED TO CONSTANT SURVEILLANCE.
Hydraulic system of a carrier machine should be maintained according to the service program. All couplings,
valves and hoses of the system should be leak-proof and kept clean in order to follow their technical condition.
Hydraulic leakages must be rectified immediately to avoid injuries caused by hot oil blowouts.
Prior to maintenance, detaching from a carrier or disassembling a DYNASET-unit, the hydraulic system of a
machine should be stopped and DYNASETs hydraulic circuit depressurised.
When working with a DYNASET hydraulic equipment, appropriate protective clothing, safety goggles and gloves
should be worn. Do not touch parts heated by hydraulic oil.
WHEN CARRYING OUT ANY SERVICE DISASSEMBLING OR REPAIR OF DYNASET HYDRAULIC UNIT (AND/OR
HYDRAULIC SYSTEM OF A CARRIER MACHINE), ABSOLUTE CLEANLINESS MUST BE MAINTAINED TO ENSURE
RELIABLE AND TROUBLE-FREE OPERATION OF YOUR EQUIPMENT.
All installation and service of both hydraulic and electric equipment must be performed by qualified and
experienced personnel only.
WARRANTY
DYNASET products are warranted against defects in materials and workmanship for a period of 6 (six) months
from the date of purchase. Exceptions are parts subject to normal wear and tear, such as seals and other parts
that become worn through normal use of the unit.
Warranty covers detective parts solely. Expenditure incidental to shipping and replacement are not covered
by present warranty.
The warranty is void if product has been modified, provided with parts other than original or misused.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 9 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
1. 1.1 1.1
MAGNET DOES NOT Magnet unplugged or magnets cable Replug the magnet; change the cable if damaged.
WORK damaged.
Red failure indication LED on PCI-card is
ON.
1.2 1.2
220 VDC voltage does not come from the Contactors K1 breaker points are worn. Check their resistance
control unit to magnets terminals. when the contactor is engaged. Correct value is 0,2 Ohm.
1.3 1.3
AC-voltage does not come from generator Check whether there is a 3-phase voltage 150 - 180 VAC on
to the control unit. terminals T1, T2 and T3 of contactor K1.
Potential malfunction in hydraulic system.
Potential failure in AC-generators windings, brush gear,
excitation rectifier or voltage regulator.
Ref. to the attached troubleshooting for AC-generator.
1.4 1.4
Malfunction in contactor K1 and K2 Check control wiring, especially magnets push-button and
control. The contactors must be engaged. generators starting switch.
Check the PCI-card, replace the fuse if blown.
Test contactor operation: press the magnets control push-
button and follow LEDs sequence (ref. to the item OPERATION).
Replace the PCI-card if damaged.
Ref. also to the attached instructions for PCI-card.
1.5 1.5
Contactors K2 breaker points are worn. Check resistance of breaker points when the contactor is
engaged. Correct value is 0,2 Ohm.
1.6 1.6
Magnets coil is damaged. Check coils resistance and compare the result to the value
indicated in the table thereinafter. Check also coils inductance
if possible.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 10 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... TROUBLESHOOTING
2. 2.1 2.1
IRON DOES NOT GET Contactors K1 and K3 do not operate in Test contactor operation: press the magnets control push-
RELEASED FROM A correct sequense. button and follow LEDs sequence (ref. to the item
MAGNET
(DEMAGNETISATION DOES OPERATION). Replace the PCI-card if damaged.
NOT WORK) Ref. also to the attached instructions for PCI-card.
2.2 2.2
Contactors K3 breaker points are worn. Check resistance of breaker points when the contactor is
engaged. Correct value is 0,2 Ohm.
3.1 3.1.1
3.
Magnet keeps working only a short time. Magnets power demand exceeds HMGs output. Generator
MAGNET
MALFUNCTIONS. gets overloaded and stopped by an automatic circuit breaker.
Choose magnet according to HMGs power output.
3.1.2
Magnets cables short-circuit. Automatic circuit breaker
stops the generator.
Unplug the magnet; if circuit breaker does not trip shortly
after starting the generator, cable is damaged.
3.1.3
Control unit overheated.
Control unit's thermostat switch tripped by reason of L-
resistors failure.
Insufficient cooling.
3.2 3.2
Low magnets power. Magnets voltage too low:
Does DC-voltage come to magnets terminals ?
Does AC-voltage comes to the control unit ?
3.3 3.3
Magnets power consumption excessive, Generators output voltage too high causing overloading.
automatic circuit breaker stops the Check AC-generator according the attached instructions;
generator. Check actuating hydraulics.
Adjust the output voltage to proper level.
ATTN ! High voltage is hazardous to a generator. Rectify
a malfunction immediately.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 11 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... TROUBLESHOOTING
MAGNETS RESISTANCE
(Ohm)
min max
HMG 3 kW 15 50
HMG 6 kW 8,8 20
HMG 10,0 kW 5,4 15
HMG 12,0 kW 4,5 10
HMG 15,0 kW 3,6 8
HMG 20,0 kW 2,6 6
HMG 30,0 kW 1,7 5
malfunction indicator
impulse button
solenoid + 24V LED
+ 24V
24 VDC- ground
contactor ground contact indicator LEDs
capacitor contactors K1, K2, K3
capacitor
contactor 1 + 24V
contactor 2 + 24V
contactor 3 + 24V
demagnetisation
current adjustment
Contactor K2
release current adjustment CURRENT TRANSDUCER
1.
CONTROL VOLTAGE LED 24 V (GREEN) activates when the main switch is turned ON.
If the LED is off, either the control wire is damaged or the fuse (6,3 A) has blowed.
2.
If LED is ON, but the contactor still disengaged, whether contactors coil or wire is
damaged.
If LEDs are off constantly, the PCI-card does not work properly.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 12 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... TROUBLESHOOTING
3.
The concerned LED indicates control voltage failure and malfunction of magnet current metering
circuit.
If LED is continuously ON when working:
3.1 Magnet cable is disconnected or damaged.
3.2 Current metering circuit of PCI-card damaged or the PCI-card is not adjusted
properly (check the set value of potentiometers VIRTA1 and VIRTA2).
3.3 If led keeps flashing after working cycle, the wire of 24V has poor contact.
The LED starts flashing when 24V voltage cuts off for longer time than 0,2 s.
SAFE MODE
PCI CONTROL CARD runs in safe mode when a failure occurs. MALFUNCTION INDICATOR LED
is ON continuously, but the job can be continued without immediate tracing and rectifying the failure.
In SAFE MODE fixed demagnesation time is 6 sec, however magnets considerable inductance may
extend the above time with 1 - 3 seconds.
The PCI card runs in SAFE MODE when the HMG-generator is ON, but the magnet cable is disconnected.
PCI-card measures automatically the inductive current and disengages the contactor
K2 at the right time without arcing, regardless of magnet inductance (0 - 20 H) and
power.
To speed up the opening time of contactor K2, V1-value can be increased to 330 mV
( = 8,3A) by setting the potentiometer VIRTA1 counter-clockwise (max. 1 rev. = 30 mV.
DO NOT increase too much because that reduces the service life of contactor K2.
Adjusted demagnetising current value can be gauged with mV-meter between measure
points V2- and GND of the card, when the control voltage 24V is ON.
Factory default is -100 mV (= 2,5 A). Demagnetising can be increased upto -130 mV (=3,25 A)
by setting the potentiometer VIRTA2 clockwise (1 round = 30 mA).
When the magnet is connected and energised, the current can be gauged between measure
points VM- and GND of the card.
Factory default scale is 1A = 40 mV (i.e. magnet current of 10A is gauged as 400 mV).
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 13 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
1. 1.1 1.1.1
LOW OUTPUT VOLTAGE AT Too low rotation speed of generator. Check first the output frequency. If the frequency is out
NO LOAD of range, hydraulic system failure is concerned.
1.1.2
Check whether the hydraulic fluid flow and pressure are
sufficient. Adjust when necessary.
1.1.3
Check the hydraulic motor for possible leakage. Replace
motor if necessary.
1.2 1.2
Excitation rectifiers failure. Trace the failure and replace the rectifier.
1.3 1.3
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring (HMG6 HMG20
kW).
1.4
Voltage regulators failure. 1.4.1
Replace the capacitor (HMG 3 kW).
1.4.2
Check the compound regulator. Replace if broken (HMG6
HMG20 kW).
1.4.3
Check and adjust or replace the electronic regulator (HMG30
kW).
1.5 1.5
Winding failure. Check the condition of winding; verify windings resistance
with parameters shown in technical specification and
replace if damaged.
ATTN !
To avoid damaging the control unit set the overload
protection switch to OFF-opsition prior to measuring
windings insulation resistance.
2. 2.1 2.1
LOW OUTPUT VOLTAGE AT The generator is being overloaded. Reduce the load and check the current I (A) to ensure that
LOAD, WHILE NO-LOAD the proper load is being applied.
VOLTAGE IS CORRECT
2.2 2.2.1
Too low rotation speed of generator. Hydraulic pressure insufficient.
2.2.2
Hydraulic system failure to be traced and cleared.
2.2.3
Hydraulic motor worn out. Replace hydraulic motor.
2.3 2.3.1
Voltage regulators failure. Replace the capacitor (HMG 3 kW).
2.3.2
Check and adjust or replace the compound regulator.
(HMG6 HMG20 kW).
Check resistors of rotors current circuit (2 pcs).
2.3.3
Check and adjust or replace the electronic regulator (HMG30
kW).
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 14 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... TROUBLESHOOTING
AC-GENERATORS TROUBLESHOOTING
3. 3.1 3.1
EXCITATION FAILURE Rectifiers failure. Trace the failure and replace the rectifier.
3.2 3.2.1
Voltage regulators failure. Replace the capacitor (HMG3 kW).
3.2.2
Check and adjust or replace the compound regulator (HMG6
HMG20 kW).
3.2.3
Check and adjust or replace the electronic regulator (HMG30
kW).
3.3 3.3
Winding failure. Verify the winding resistance with parameters shown in
technical specification and replace if damaged.
3.4 3.4
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring
(HMG6 HMG20 kW).
3.5 3.5
Insufficient residual magnetism. Use external battery of 12 V for 1 - 2 sec to magnetise the
rotor.
4. 4.1 4.1.1
OUTPUT VOLTAGE Instable rotation speed of generator. Check generators hydraulics, including automatic frequency
INSTABILITY control valve. Make an adjustment, replace RPM-cartridge
if necessary.
4.1.2
Check whether the hydraulic fluid flow and pressure are
excessive. Adjust when necessary.
4.1.3
Check the hydraulic motor for possible leakage. Replace
motor if necessary.
4.2 4.2
Electronic voltage regulators failure Adjust stability of the regulator.
(HMG30 kW). Replace if broken.
4.3 4.3
Poor contact in electric system. Check all internal contacts and wiring of the generator.
Check and clean brushes and slip ring (HMG6 HMG20 kW).
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 15 MAY CHANGE WITHOUT PRIOR NOTICE.
Internet: http://www.dynaset.com February 2003/kl
... TROUBLESHOOTING
AC-GENERATORS TROUBLESHOOTING
5. 5.1 5.1
ABNORMAL NOISE LEVEL Bearing failure. Replace broken bearing.
5.2 5.2
Generator is being overloaded. Reduce the load to proper level.
5.3 5.3
Short circuit in powered unit. Check powered unit. Rectify a defect.
5.4 5.4
Foreign items in generators casing. Stop generator and hydraulic system. Remove foreign item
from unit.
5.5 5.5
Extremely fluctuating load. Can it be fixed ?
6. 6.1 6.1
OIL LEAKAGES Failure of axial sealing of generators Axial sealing of hydraulic motor broken
hydraulic motor. External indication by reason of EXCESSIVE PRESSURE IN RETURN LINE.
ydraulic oil outflow from ventilation grids. Rebuild the return line. Maximum allowed pressure in return
line is 5 bar.
Replace axial sealing of generators motor.
6.2 6.2
Oil leakage from hydraulic motor. Hydraulic motor worn out and should be replaced.
DYNASET OY, Menotie 3 Tel.: +358 3 3488200 Fax: +358 3 3488222 E-mail: info @dynaset.com
FIN-33470 Ylöjärvi, FINLAND 16 MAY CHANGE WITHOUT PRIOR NOTICE.
PARAMETERS PCI-MODELS
17
HYDRAULIC CONNECTIONS
Pressure line P BSP 1/2 BSP 1/2 BSP 1/2 BSP 1/2 BSP 3/4 BSP 3/4 BSP 3/4
Return line T BSP 1/2 BSP 1/2 BSP 1/2 BSP 1/2 BSP 1 BSP 1 BSP1
Serial connection S BSP 3/8 BSP 3/8 BSP 3/8 BSP 3/8 NO NO NO
HYDRAULIC REQUIREMENTS
Minimal flow l/min 18 32 46 55 68 95 123
Maximum flow l/min 30 62 66 65 95 115 150
Pressure at nominal power bar 190 190 190 190 190 190 190
OUTLINE DIMENSIONS
Length mm 420 475 485 540 790 790 1070
Width mm 290 365 390 390 430 430 550
Height mm 250 310 360 360 450 450 600