MITSUBISHI GENERATOR SERIES

MGS
for Data Center Power Systems
RELIABILITY AND QUALITY IN POWER GENERATION

MITUBISHI HEAVY INDUSTRIES ENGINE & TURBOCHARGER, LTD. MITUBISHI HEAVY INDUSTRIES ENGINE SYSTEM ASIA PTE. LTD.
Engine & Energy Division, Engine Sales Department No. 3, Tuas Avenue 12, Singapore 639024, Republic of Singapore
3000 Tana, Chuo-ku, Sagamihara, Kanagawa 252-5293, Japan Phone: 65-6862-2202 Fax: 65-6862-5728
Phone: 81-42-761-2056 Fax: 81-42-761-8051 www.mhiesa.com/
www.mhiet.co.jp/en/
Data Center is Core of Every Society Sales Record & Delivery Example

The market environment in recent years surrounding the data center has been MGS Total Sales Record
being rapidly changing from the form that enterprises and individuals have
managed and possessed hardware, software, data, etc. to the form that Since the launch of the MGS series, No. of Units
Cumulative Production
various information systems of enterprises and individuals are installed in the
there are over 10,000 units worldwide. 12,000

data center.
10,000 Total: over 10,000 units
Amid these changes in the times, data centers are increasing their presence in MGS series are our core product
modern business scenes, and along with this situation the facility standards which has gained great reliability 8,000

that the market seeks at the data center are also changing to severe. from customers all over the world 6,000

4,000

2,000

0
4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6
199 199 199 199 199 199 200 200 200 200 200 200 200 200 200 200 201 201 201 201 201 201 201
Year

Delivery Example for Data Center

- Company Name
MC Digital Realty, Inc.
(Co-locator)
- Location
Build data center facility to provide server
Co-locator space for third party company
Mitaka, Tokyo

Build data center facility to manage their


3 Categories of Data Center Enterprise data that is related to their main business
for own company (Ex. Financial institution)

Build and manage many large-scale data center


Digitals facilities to provide their cloud servicing (Ex.
- Diesel Generator Sets
Google, Microsoft)

2,500kVA (Engine: S16R2-PTAW)


Diesel Generator Sets
The MHIET Group will develop many power Concept of Diesel Engine Generator Set for Data Centers N+1 Redundancy
generation systems that requires exclusive
- Data centers are operating in 24 hours / 7 days.
specs for the data center to fully support - Thus the electric power supply facility is most
such changes in the business environment. important for them. MHIET group Engines and Generator sets
- The demands of diesel engine generator sets from
We will bring together the technologies the data centers are mainly 3 points in below. are installed in data center facilities around
that the MHIET Group has cultivated over the world including in MC Digital Realty, Inc.
Startability Size Global Standard
many years and contribute to the stable - Quick start - Power ratio - Apply ISO standard
operation of the data center. - High reliability - Footprint - Meet requirement of Uptime Institute

1 2
Data Center is Core of Every Society Sales Record & Delivery Example

The market environment in recent years surrounding the data center has been MGS Total Sales Record
being rapidly changing from the form that enterprises and individuals have
managed and possessed hardware, software, data, etc. to the form that Since the launch of the MGS series, No. of Units
Cumulative Production
various information systems of enterprises and individuals are installed in the
there are over 10,000 units worldwide. 12,000

data center.
10,000 Total: over 10,000 units
Amid these changes in the times, data centers are increasing their presence in MGS series are our core product
modern business scenes, and along with this situation the facility standards which has gained great reliability 8,000

that the market seeks at the data center are also changing to severe. from customers all over the world 6,000

4,000

2,000

0
4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6
199 199 199 199 199 199 200 200 200 200 200 200 200 200 200 200 201 201 201 201 201 201 201
Year

Delivery Example for Data Center

- Company Name
MC Digital Realty, Inc.
(Co-locator)
- Location
Build data center facility to provide server
Co-locator space for third party company
Mitaka, Tokyo

Build data center facility to manage their


3 Categories of Data Center Enterprise data that is related to their main business
for own company (Ex. Financial institution)

Build and manage many large-scale data center


Digitals facilities to provide their cloud servicing (Ex.
- Diesel Generator Sets
Google, Microsoft)

2,500kVA (Engine: S16R2-PTAW)


Diesel Generator Sets
The MHIET Group will develop many power Concept of Diesel Engine Generator Set for Data Centers N+1 Redundancy
generation systems that requires exclusive
- Data centers are operating in 24 hours / 7 days.
specs for the data center to fully support - Thus the electric power supply facility is most
such changes in the business environment. important for them. MHIET group Engines and Generator sets
- The demands of diesel engine generator sets from
We will bring together the technologies the data centers are mainly 3 points in below. are installed in data center facilities around
that the MHIET Group has cultivated over the world including in MC Digital Realty, Inc.
Startability Size Global Standard
many years and contribute to the stable - Quick start - Power ratio - Apply ISO standard
operation of the data center. - High reliability - Footprint - Meet requirement of Uptime Institute

1 2
Main Features Advanced Features

Mitsubishi Engines and Turbochargers


Make Best Performance of Mitsubishi Gensets Advanced Solution in 7310 and 7320 Control System

MHIET group has continually introduced upgraded "Full-sized" safety and automatic
its engine products since the inception of business functions in the series of digital control
in 1917, and now the MGS provides a higher systems.
generating power rating and more advanced control
systems than ever before, with proven reliability Easy human interface in the sophisticated
based on the continued research and development. control system makes for an
The best performance-matched engine system operator-friendly Gen Set.
configured with Mitsubishi diesel engines and
Mitsubishi turbochargers, which are engineered
and manufactured in the same facility, is certain
to result in the high productivity and improved
fuel economy in the MGS power generation.
MGS - All Mitsubishi assembled, tested and supported.

High Reliability and Quality in MGS Remote Monitoring System (RMS)

It takes no more than 10 seconds from Our compact MGS series makes more
receiving the signal to start reaching the rated space to have servers or other devices - MGS operating condition
voltage and frequency, which minimizes the in your facilities.
impact of power outages. Cloud - MGS total operating hour
server
- Warning & Shutdown alarm
- Alarm e-mail
- Monitor current condition
Quick Start Space Saving

3G signal Mobile phone Laptop PC

Five Nines Green


Engineering Technology

SIM

Wireless router Gateway unit

RMS module in a box MGS


Our ultimate goal is 99.999% availability. Mitsubishi's fuel injector and high-pressure
MHIET group provides total engineering and fuel pump make it possible to burn the fuel
service support to accomplish 99.999% completely and achieve clean emission gas.
availability of your power systems. *In some countries or regions, it is not able to be possible to install a remote monitoring system because of their laws, regulations or other reasons.
*Some devices are needed to install RMS.

3 4
Main Features Advanced Features

Mitsubishi Engines and Turbochargers


Make Best Performance of Mitsubishi Gensets Advanced Solution in 7310 and 7320 Control System

MHIET group has continually introduced upgraded "Full-sized" safety and automatic
its engine products since the inception of business functions in the series of digital control
in 1917, and now the MGS provides a higher systems.
generating power rating and more advanced control
systems than ever before, with proven reliability Easy human interface in the sophisticated
based on the continued research and development. control system makes for an
The best performance-matched engine system operator-friendly Gen Set.
configured with Mitsubishi diesel engines and
Mitsubishi turbochargers, which are engineered
and manufactured in the same facility, is certain
to result in the high productivity and improved
fuel economy in the MGS power generation.
MGS - All Mitsubishi assembled, tested and supported.

High Reliability and Quality in MGS Remote Monitoring System (RMS)

It takes no more than 10 seconds from Our compact MGS series makes more
receiving the signal to start reaching the rated space to have servers or other devices - MGS operating condition
voltage and frequency, which minimizes the in your facilities.
impact of power outages. Cloud - MGS total operating hour
server
- Warning & Shutdown alarm
- Alarm e-mail
- Monitor current condition
Quick Start Space Saving

3G signal Mobile phone Laptop PC

Five Nines Green


Engineering Technology

SIM

Wireless router Gateway unit

RMS module in a box MGS


Our ultimate goal is 99.999% availability. Mitsubishi's fuel injector and high-pressure
MHIET group provides total engineering and fuel pump make it possible to burn the fuel
service support to accomplish 99.999% completely and achieve clean emission gas.
availability of your power systems. *In some countries or regions, it is not able to be possible to install a remote monitoring system because of their laws, regulations or other reasons.
*Some devices are needed to install RMS.

3 4
Rating Table Service Network

Low Voltage High Voltage The preferred worldwide equipment


MITSUBISHI GENERATOR SERIES (MGS) - the way to serve customers
- Best available products with the best possible value
50 Hz/1500 min-1/380-415 V 50 Hz/1500 min-1
- Best quality service support with the sense of urgency
Data CenterPower
Generator set Engine Model
Data Center Power
Generator set Engine Model
Code: DCP* (kVA) - Beyond the customer's expectation
Code: DCP* (kVA)
3.3 kV 6.6 kV 10 kV 11 kV

MGS2800 S16R2-PTAW2-S 2500 MGS2800HV S16R2-PTAW2-S 2500 2500 2500 2500


Your local MGS genset dealer can advise you on the right selection of MGS genset
MGS2700 S16R2-PTAW 2250 MGS2700HV S16R2-PTAW 2250 2250 2250 2250
for your application, deliver and install the units properly, and provide daily
maintenance on demand, to support higher productivity in economical way.
MGS2500 S16R-PTAA2 2035 MGS2500HV S16R-PTAA2 2010 2010 2010 2005
Well trained and experienced professionals strive for excellence in all they do.
MGS2000 S16R-PTA2-S 2030 MGS2000HV S16R-PTA2-S 2000 2000 2000 2000

MGS1500 S16R-PTA-S 1810 MGS1500HV S16R-PTA-S 1810 1810 1800 1800

MGS1400 S12R-PTA2-S 1450 MGS1400HV S12R-PTA2-S 1450 1450 1450 1450

MGS1200 S12R-PTA-S 1362.5 MGS1200HV S12R-PTA-S 1350 1350 1340 1340


MHIET Group Network
60 Hz/1800 min-1/380 V 60 Hz/1800 min-1
Data Center Power
Data Center Power Code: DCP* (kW)
Generator set Engine Model Generator set Engine Model
Code: DCP* (kW)
3.3 kV 4.16 kV 6.6 kV 13.8 kV North America Europe & Middle East Japan HQ & China

MGS2500 S16R-PTAA2 1810 MGS2500HV S16R-PTAA2 1800 1800 1800 1800

MGS2000 S16R-PTA2-S 1730 MGS2000HV S16R-PTA2-S 1700 1700 1700 1700 MTEE

MGS1500 S16R-PTA-S 1550 MGS1500HV S16R-PTA-S 1500 1500 1460 1500 MEA

MGS1400 S12R-PTA2-S 1280 MGS1400HV S12R-PTA2-S 1280 1280 1280 1280


MTEA
Headquarter
MGS1200 S12R-PTA-S 1145 MGS1200HV S12R-PTA-S 1140 1140 1140 1140 Sagamihara, Japan

MESA SME

-1
60 Hz/1800 min /480 V
MSA MHISH

MHIES-ME
*Data Center Power (DCP)
MHIES-P
Data Center Power Data center power is defined as being the maximum power which a South America
Generator set Engine Model
Code: DCP* (kW) generating set is capable of delivering while supplying a variable or
MVDE MHIES-V
continuous electrical load and during unlimited run hours. Depending on Africa Asia
MGS2500 S16R-PTAA2 1820 the sites to supply and the availability of reliable utility, the generating set Production
manufacturer is responsible to define what power level he is able to supply Sales MHIES-I MHIES-A
After-Sales Service
MGS2000 S16R-PTA2-S 1730 to fulfill that requirement including hardware or software or maintenance Assembly (Power Generators)
plan adaptation. Operation and Maintenance
MGS1500 S16R-PTA-S 1550
(ISO 8528-1:2018)
MGS1400 S12R-PTA2-S 1280
Asia Europe
MGS1200 S12R-PTA-S 1150
Mitsubishi Heavy Industries Engine System Asia Pte. Ltd. (MHIES-A) Mitsubishi Turbocharger and Engine Europe B.V. (MTEE)
MHI Engine System Vietnam Co., Ltd. (MHIES-V) North America, South America
MHI Engine System Philippines, Inc. (MHIES-P)
Mitsubishi Turbocharger and Engine America, Inc. (MTEA)
PT. MHI Engine System Indonesia (MHIES-I)
MHI Sul Americana Distribuidora de Motores Ltda.(MSA)
MHI Engine System Middle East FZE (MHIES-ME)
Japan HQ
Uptime Institute China
Mitsubishi Heavy Industries Engine & Turbocharger, Ltd. (MHIET)
Mitsubishi Generator Series comply with the requirement of a Tier Ⅲ and Tier Ⅳ data center facility Mitsubishi Heavy Industries (Shanghai) Co., Ltd. (MHISH)
which shall not have a limitation on consecutive hours of operation when loaded to 'N' demand. Shanghai MHI Engine Co., Ltd. (SME)

* If you need to have more information about our group company, please check MHIET website.
5 6
Rating Table Service Network

Low Voltage High Voltage The preferred worldwide equipment


MITSUBISHI GENERATOR SERIES (MGS) - the way to serve customers
- Best available products with the best possible value
50 Hz/1500 min-1/380-415 V 50 Hz/1500 min-1
- Best quality service support with the sense of urgency
Data CenterPower
Generator set Engine Model
Data Center Power
Generator set Engine Model
Code: DCP* (kVA) - Beyond the customer's expectation
Code: DCP* (kVA)
3.3 kV 6.6 kV 10 kV 11 kV

MGS2800 S16R2-PTAW2-S 2500 MGS2800HV S16R2-PTAW2-S 2500 2500 2500 2500


Your local MGS genset dealer can advise you on the right selection of MGS genset
MGS2700 S16R2-PTAW 2250 MGS2700HV S16R2-PTAW 2250 2250 2250 2250
for your application, deliver and install the units properly, and provide daily
maintenance on demand, to support higher productivity in economical way.
MGS2500 S16R-PTAA2 2035 MGS2500HV S16R-PTAA2 2010 2010 2010 2005
Well trained and experienced professionals strive for excellence in all they do.
MGS2000 S16R-PTA2-S 2030 MGS2000HV S16R-PTA2-S 2000 2000 2000 2000

MGS1500 S16R-PTA-S 1810 MGS1500HV S16R-PTA-S 1810 1810 1800 1800

MGS1400 S12R-PTA2-S 1450 MGS1400HV S12R-PTA2-S 1450 1450 1450 1450

MGS1200 S12R-PTA-S 1362.5 MGS1200HV S12R-PTA-S 1350 1350 1340 1340


MHIET Group Network
60 Hz/1800 min-1/380 V 60 Hz/1800 min-1
Data Center Power
Data Center Power Code: DCP* (kW)
Generator set Engine Model Generator set Engine Model
Code: DCP* (kW)
3.3 kV 4.16 kV 6.6 kV 13.8 kV North America Europe & Middle East Japan HQ & China

MGS2500 S16R-PTAA2 1810 MGS2500HV S16R-PTAA2 1800 1800 1800 1800

MGS2000 S16R-PTA2-S 1730 MGS2000HV S16R-PTA2-S 1700 1700 1700 1700 MTEE

MGS1500 S16R-PTA-S 1550 MGS1500HV S16R-PTA-S 1500 1500 1460 1500 MEA

MGS1400 S12R-PTA2-S 1280 MGS1400HV S12R-PTA2-S 1280 1280 1280 1280


MTEA
Headquarter
MGS1200 S12R-PTA-S 1145 MGS1200HV S12R-PTA-S 1140 1140 1140 1140 Sagamihara, Japan

MESA SME

-1
60 Hz/1800 min /480 V
MSA MHISH

MHIES-ME
*Data Center Power (DCP)
MHIES-P
Data Center Power Data center power is defined as being the maximum power which a South America
Generator set Engine Model
Code: DCP* (kW) generating set is capable of delivering while supplying a variable or
MVDE MHIES-V
continuous electrical load and during unlimited run hours. Depending on Africa Asia
MGS2500 S16R-PTAA2 1820 the sites to supply and the availability of reliable utility, the generating set Production
manufacturer is responsible to define what power level he is able to supply Sales MHIES-I MHIES-A
After-Sales Service
MGS2000 S16R-PTA2-S 1730 to fulfill that requirement including hardware or software or maintenance Assembly (Power Generators)
plan adaptation. Operation and Maintenance
MGS1500 S16R-PTA-S 1550
(ISO 8528-1:2018)
MGS1400 S12R-PTA2-S 1280
Asia Europe
MGS1200 S12R-PTA-S 1150
Mitsubishi Heavy Industries Engine System Asia Pte. Ltd. (MHIES-A) Mitsubishi Turbocharger and Engine Europe B.V. (MTEE)
MHI Engine System Vietnam Co., Ltd. (MHIES-V) North America, South America
MHI Engine System Philippines, Inc. (MHIES-P)
Mitsubishi Turbocharger and Engine America, Inc. (MTEA)
PT. MHI Engine System Indonesia (MHIES-I)
MHI Sul Americana Distribuidora de Motores Ltda.(MSA)
MHI Engine System Middle East FZE (MHIES-ME)
Japan HQ
Uptime Institute China
Mitsubishi Heavy Industries Engine & Turbocharger, Ltd. (MHIET)
Mitsubishi Generator Series comply with the requirement of a Tier Ⅲ and Tier Ⅳ data center facility Mitsubishi Heavy Industries (Shanghai) Co., Ltd. (MHISH)
which shall not have a limitation on consecutive hours of operation when loaded to 'N' demand. Shanghai MHI Engine Co., Ltd. (SME)

* If you need to have more information about our group company, please check MHIET website.
5 6
MITSUBISHI GENERATOR SERIES

MGS
for Data Center Power Systems
RELIABILITY AND QUALITY IN POWER GENERATION

MITUBISHI HEAVY INDUSTRIES ENGINE & TURBOCHARGER, LTD. MITUBISHI HEAVY INDUSTRIES ENGINE SYSTEM ASIA PTE. LTD.
Engine & Energy Division, Engine Sales Department No. 3, Tuas Avenue 12, Singapore 639024, Republic of Singapore
3000 Tana, Chuo-ku, Sagamihara, Kanagawa 252-5293, Japan Phone: 65-6862-2202 Fax: 65-6862-5728
Phone: 81-42-761-2056 Fax: 81-42-761-8051 www.mhiesa.com/
www.mhiet.co.jp/en/

You might also like