Component Type SS21-UL Type: Speed Control Motors
Component Type SS21-UL Type: Speed Control Motors
Component Type SS21-UL Type: Speed Control Motors
COMPONENT Type
SS21-UL Type
Features
A tachogenerator built into induction motors, in
combination with the specially designed control ●Speed control range is 90 1700 r/min.
●Each motor and control pack is recognized by UL.
pack, allows multi-functional operation such as
●Easy electrical connections due to the plug-in pin construction.
speed control, and direct control from
programmable controllers.
Specifications
Model SS21-UL
Voltage AC115V10%
Frequency 60Hz
Current 1.5A Max.
Operable Motor Output Power 6W40W
Speed Range 90r/min1700r/min
Ambient Temperature 32˚F104˚F (0˚C40˚C)
Ambient Humidity 85% Maximum. (Noncondensing)
Note that these models cannot be used for applications requiring the control of
more than one motor/control-pack set by the same external potentiometer.
SAFETY AC
STD. INPUT
2IK6RGN-AUL 2IK6RA-AULA 1/124 6 115 60 901700 6.9 50 2.5 18 4.6 33 0.25 25 2.0 250
3IK15RGN-AUL 3IK15RA-AULA 1/50 15 115 60 901700 11.7 84.5 4.3 31 8.3 60 0.46 38 4.0 250
4IK22RGN-AUL 4IK22RA-AULA 1/34 22 115 60 901700 25.0 180 8.3 60 15.3 110 0.52 50 5.0 250
5IK40RGN-AUL 5IK40RA-AULA 1/18.5 40 115 60 901700 25.0 180 7.6 55 27.8 200 0.83 58 8.0 250
●2IK type is impedance protected. ●The speed range is under no load condition.
●3IK, 4IK and 5IK type motors contain a built-in thermal protector. If a motor ●The UL recognized speed control motors are designed for the SS21-UL type
overheats for any reason, the thermal protector is opened and the motor stops. speed control pack. Motor cannot be combined with other types of control
When the motor temperature drops, the thermal protector closes and the motor packs.
restarts. Be sure to turn the motor off before inspecting. ●Note that these models cannot be used for applications requiring the control of
more than one motor/control-pack set by the same external potentiometer.
General Specifications of Motors
Item Specifications
100M ohms or more when 500V DC is applied between the windings and the frame after rated motor operation under normal ambient
Insulation Resistance
temperature and humidity.
Sufficient to withstand 1.5kV at 50Hz and 60Hz applied between the windings and the frame after rated motor operation under normal ambient
Dielectric Strength
temperature and humidity.
135°F (75°C) or less measured by the resistance change method after the temperature of the coil has stabilized under normal operation at the
Temperature Rise
rated voltage and frequency.
Overheating Built-in thermal protector (Automatic return type)
Protection Device Open: 248°F9°F (120°C5°C) Close: 170.6°F27°F (77°C 15°C )
Insulation Class Class A
Ambient Temperature Range 14°F 104°F (10°C
40°C)
Ambient Humidity 85% Maximum (Noncondensing)
●2IK type is impedance protected. This type of motor does not contain a built-in thermal protector.
Low Speed 30 25 18 15 12 10 7 6 5 3.6 3 2.5 1.8 1.5 1.2 1.0 0.9 0.75 0.6 0.5
3IK15RGN-AUL 5IK40RGN-AUL
3IK15RA-AULA 5IK40RA-AULA
SS21-UL SS21-UL
Wiring Diagrams
Uni-directional, speed control
Speed Control
Setting The Speed
The speed is set by either an external potentiometer. These
values correspond to the minimum and the maximum setting
of the speed potentiometer used for speed control. Motor
speed can be adjusted over the range from 90 r/min to 1700
r/min at 60Hz.
Note: The speed control inputs of the control packs must be isolated from each
other. Therefore, only one control pack at a time can be controlled by a
single potentiometer.
5IK40RA-AULA
Weight (Mass): 5.73 lb.(2.6 kg)
.51(13) .59(15)
.008(0.2) .016(0.4) M4 P0.7.24(6) 1.57(40) 1.57(40)
(Screw) .394(100.5)
Brass insertion
1.571.57(4040)
.94DIA.( 24)
.49(12.5)
50
.12DIA.( 3)
40 60
.79(20)
30 70
1.57(40)
1.57(40)
20 80
.126DIA. .374DIA. 10 90
.12(3)
(3.20.2) (9.50.2) 0 100
Potentiometer
Insulated sheet
1.571.57(4040) Insulated sheet Dial Plate
Knob
Dial plate
1.571.57(4040)
Socket
EP11PF Scale 1/4, Unit = inch (mm)