Professional Documents
Culture Documents
B-63833en 02 (Hardware)
B-63833en 02 (Hardware)
B-63833EN/02
Ȧ No part of this manual may be reproduced in any form.
Ȧ All specifications and designs are subject to change without notice.
This manual includes safety precautions for protecting the user and preventing damage to the
machine. Precautions are classified into Warning and Caution according to their bearing on safety.
Also, supplementary information is described as a Note. Read the Warning, Caution, and Note
thoroughly before attempting to use the machine.
WARNING
Applied when there is a danger of the user being injured or when there is a damage of both the user
being injured and the equipment being damaged if the approved procedure is not observed.
CAUTION
Applied when there is a danger of the equipment being damaged, if the approved procedure is not
observed.
NOTE
The Note is used to indicate supplementary information other than Warning and Caution.
s–1
B–63833EN/02 PREFACE
PREFACE
Applicable models The models covered by this manual, and their abbreviations are:
Product name Abbreviation
p–1
PREFACE B–63833EN/02
Chapter 1 Outlines connections for the Series 0i/0i Mate and guides the reader concern-
CONFIGURATION ing additional details.
Chapter 3 This chapter describes the installation conditions for the Series 0i/0i Mate.
INSTALLATION 1) Required power supply
2) Heat generated
3) Connector arrangement on the control unit
4) Noise prevention
Chapter 5 This chapter describes how to connect the following peripheral devices:
CONNECTING PERIPHERAL UNITS 1) Display devices (CRT and LCD display)
2) MDI units
3) I/O devices (via RS232C)
4) Manual pulse generators
Chapter 6 This chapter describes how to connect the spindle servo unit, the spindle mo-
CONNECTING THE SPINDLE UNIT tor.
Chapter 7 This chapter describes how to connect the servo unit and the servo unit.
SERVO INTERFACE
Chapter 8 This chapter describes the addresses and connector pins for signals trans-
CONNECTING THE MACHINE INTER- ferred between the Series 0i/0i Mate and the machine.
FACE I/O Describes the built–in I/O board.
Chapter 9 This chapter describes the use of FANUC I/O Link to expand the machine
CONNECTION TO FANUC I/O Link interface I/O.
Chapter 10 This chapter describes the handling of emergency stop signals. The user
EMERGENCY STOP SIGNAL must read this chapter before attempting to operate the CNC.
Chapter 11 This chapter describes the high–speed serial bus (HSSB) supported by the
HIGH–SPEED SERIAL BUS (HSSB) Series 0i/0i Mate.
Chapter 13 This chapter lists manuals related to the Ethernet, DeviceNet, and other net-
OTHER NETWORK CONNECTION works
Chapter 14 This chapter describes the connection between the Series 0i and the CNC
CNC DISPLAY UNIT WITH PC FUNC- display unit with PC functions.
TIONS
p–2
B–63833EN/02 PREFACE
Related manuals of The following table lists the manuals related to Series 0i–B, Series 0i
Series 0i–B/0i Mate–B Mate–B.
This manual is indicated by an asterisk(*).
Specification
Manual name
number
DESCRIPTIONS B–63832EN
PROGRAMMING MANUAL
PMC
Network
OPEN CNC
p–3
PREFACE B–63833EN/02
Related manuals of The following table lists the manuals related to SERVO MOTOR αi series
SERVO MOTOR ai series Specification
Manual name
number
FANUC AC SERVO MOTOR αi series DESCRIPTIONS B–65262EN
Related manuals of The following table lists the manuals related to SERVO MOTOR β series
SERVO MOTOR β series
Specification
Manual name
number
FANUC SERVO MOTOR β series DESCRIPTIONS B–65232EN
p–4
B–63833EN/02 Table of Contents
DEFINITION OF WARNING, CAUTION, AND NOTE . . . . . . . . . . . . . . . . . . . . . . . . . . s–1
PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p–1
1. CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 NAME OF EACH PART OF CONTROL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 GENERAL OF HARDWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1 ENVIRONMENT FOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1.1 Environmental Requirements Outside the Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.2.1 Power Supply for CNC Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3 DESIGN AND INSTALLATION CONDITIONS OF THE MACHINE TOOL
MAGNETIC CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.4 THERMAL DESIGN OF THE CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.4.1 Temperature Rise Within the Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.4.2 Cooling by Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.4.3 Heat Loss of Each Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.5 ACTION AGAINST NOISE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5.1 Separating Signal Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5.2 Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.5.3 Connecting the Signal Ground (SG) of the Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.5.4 Noise Suppressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.5.5 Cable Clamp and Shield Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.6 CONTROL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.6.1 Installing the Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.7 CABLE LEAD–IN DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.8 CONNECTOR LAYOUT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
c–1
Table of Contents B–63833EN/02
6. SPINDLE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
6.1 SERIAL SPINDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6.1.1 Connection of One to Two Serial Spindles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6.2 ANALOG SPINDLE INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
6.3 POSITION CODER INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
7. SERVO INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
7.1 CONNECTION TO THE SERVO AMPLIFIERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
7.1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
7.1.2 Interface to the Servo Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
7.1.3 Separate Detector Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
7.1.4 Separate Detector Interface Unit Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
7.1.5 Connection of Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
7.1.6 Linear Scale Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
7.1.7 Stand–alone Type Pulse Coder Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
7.1.8 Input Signal Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
7.1.9 Connection of Battery for Separate Absolute Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
7.1.10 Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
7.1.11 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
7.1.12 Notes on Installing a Separate Detector Interface Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
c–2
B–63833EN/02 Table of Contents
c–3
Table of Contents B–63833EN/02
c–4
B–63833EN/02 Table of Contents
APPENDIX
A. EXTERNAL DIMENSIONS OF EACH UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
c–5
B–63833EN/02 1. CONFIGURATION
1 CONFIGURATION
1
1. CONFIGURATION B–63833EN/02
1.1 The following figure shows the configuration of FANUC Series 0i/0i
Mate control unit.
NAME OF EACH PART This manual describes how to connect the units illustrated in this diagram.
OF CONTROL UNIT The numbers in parentheses shown in the diagram are section references
for this manual.
Machine interface
9” CRT connector connector
(5.1) (8)
Servo amplifier
connector
(7.1)
2
B–63833EN/02 1. CONFIGURATION
Memory back up
battery
(4.4)
9” CRT connector
(5.1)
LCD connector
(5.1)
Power supply
connector
(4.3)
Servo amplifier
connector
(7.1)
3
1. CONFIGURATION B–63833EN/02
1.2
GENERAL OF
HARDWARE
I/O board
Main board (Series 0i only)
Main I/O
Mini slot
(Series 0i only)
S HSSB board
S Ethernet board
S DiviceNet board
S PROFIBUS board
S FL–net board
S DNC2 board
1–slot
(Series 0i Mate)
2–slot
(Series 0i)
4
B–63833EN/02 2. TOTAL CONNECTION DIAGRAM
MDI(JA2)
RS232C(JD5A) RS232C(CH.1)
RS232C(JD5B) RS232C(CH.2)
High–speed skip input (1 point)
HDI/ASP(JA40)
Analog spindle
Position coder for analog spindle
Circuit
breaker
200VAC
Circuit
AC reactor MCC breaker
200VAC
TB1 CX2A
COP10B JF1
SVM
COP10A CZ2 Servo
For servo TB1 CX2B motor
check
board
5
2. TOTAL CONNECTION DIAGRAM B–63833EN/02
Main board
Mini slot
HSSB board
To other device
ETHERNET board
PROFIBUS board
DeviceNet board
FL–net board
Mini slot
DNC2 board
To other device
DI/DO–3
(CB106)
DI/DO–4
(CB107)
Data
server
ETHERNET
(CD38T) ETHERNET
6
B–63833EN/02 2. TOTAL CONNECTION DIAGRAM
CRT/MDI unit
CRT unit
CRT(JA1) CN1 MDI unit
DC24V CN2 CK2
CK1
MDI(JA2)
RS232C(JD5A) RS232C(CH.1)
RS232C(JD5B) RS232C(CH.2)
High–speed skip input (1 point)
HDI/ASP(JA40)
Analog spindle
Position coder for analog spindle
Circuit
breaker
200VAC
Circuit
AC reactor MCC breaker
200VAC
Servo card
FSSB Optical fiber
TB1 CX2A
cable
(COP10A) COP10B JF1
(Up to 3 (FSSB) SVM
COP10A CZ2 Servo
axes) TB1 CX2B motor
TB1 CX2A
COP10B JF1
SVM
COP10A CZ2 Servo
For servo TB1 CX2B
check motor
board
7
3. INSTALLATION B–63833EN/02
3 INSTALLATION
8
B–63833EN/02 3. INSTALLATION
3.1
ENVIRONMENT FOR
INSTALLATION
3.1.1 The peripheral units and the control unit have been designed on the
Environmental assumption that they are housed in closed cabinets. In this manual
“cabinet” refers to the following:
Requirements Outside
D Cabinet manufactured by the machine tool builder for housing the
the Control Unit
control unit or peripheral units;
D Operation pendant, manufactured by the machine tool builder, for
housing the control unit or operator’s panel.
D Equivalent to the above.
The environmental conditions when installing these cabinets shall
conform to the following table. Section 3.3 describes the installation and
design conditions of a cabinet satisfying these conditions.
Operating 0°C to 55°C
Ambient
Temperature Storage, Transport –20°C to 60°C
Operating Up to 1000 m
Meters above
sea level Non–operating Up to 12000 m
9
3. INSTALLATION B–63833EN/02
3.2
POWER SUPPLY
3.2.1 The following units related to the CNC control unit require input power
Power Supply for CNC of 24 VDC ±10%.
Control Units Table 3.2.1 Power supply
f indicates ”Applicable.”
10
B–63833EN/02 3. INSTALLATION
CAUTION
If the air blows directly from the fan to the unit, dust easily
abheres to the unit. This may cause the unit to fail.
(4) For the air to move easily, a clearance of 100 mm is required between
each unit and the wall of the cabinet.
(5) Packing materials must be used for the cable port and the door in
oreder to seal the cabinet.
Because the CRT unit uses a voltage of approximatery 11 kV, airborne
dust gathers easily. If the cabinet is insufficiently sealed, dust passes
through the gap and abheres to the unit. This may cause the insulation
of the unit to deteriorate.
(6) The CRT unit and other display units must be installed in a location
where coolant cannot be poured directly on it. The unit does have a
dust–proof front panel.
(7) Noise must be minimized.
As the machine and the CNC unit are reduced in size, the parts that
generate noise may be placed near noise–sensitive parts in the
magnetics cabinet.
The CNC unit is built to protect it from external noise. Cabinet design
to minimize noise generation and to prevent it from being transmitted
to the CNC unit is necessary. See Sec. 3.5 for details of noise
elimination/management.
(8) The units must be installed or arranged in the cabinet so that they are
easy to inspect and maintain.
11
3. INSTALLATION B–63833EN/02
12
B–63833EN/02 3. INSTALLATION
3.4 The purpose of the thermal design of the cabinet is to limit the difference
in temperature between the air in the cabinet and the outside air to 10°C
THERMAL DESIGN OF or less when the temperature in the cabinet increases.
THE CABINET The internal air temperature of the cabinet increases when the units and
parts installed in the cabinet generate heat. Since the generated heat is
radiated from the surface of the cabinet, the temperature of the air in the
cabinet and the outside air balance at certain heat levels. If the amount
of heat generated is constant, the larger the surface area of the cabinet, the
less the internal temperature rises. The thermal design of the cabinet
refers to calculating the heat generated in the cabinet, evaluating the
surface area of the cabinet, and enlarging that surface area by installing
heat exchangers in the cabinet, if necessary. Such a design method is
described in the following subsections.
3.4.1 The cooling capacity of a cabinet made of sheet metal is generally 6 W/°C
per 1m2 surface area, that is, when the 6W heat source is contained in a
Temperature Rise
cabinet having a surface area of 1 m2, the temperature of the air in the
Within the Cabinet cabinet rises by 1°C. In this case the surface area of the cabinet refers to
the area useful in cooling , that is, the area obtained by subtracting the area
of the cabinet touching the floor from the total surface area of the cabinet.
There are two preconditions : The air in the cabinet must be circuited by
the fun, and the temperature of the air in the cabinet must be almost
constant.
The following expression must then be satisfied to limit the difference in
temperature between the air in the cabinet and the outside air to 10°C or
less when the temperature in the cabinet rises:
Internal heat loss P [W] x 6 [W/m2 @ °C ] × surface area S [m2]
× 10 [°C] of rise in temperature
For example, a cabinet having a surface area of 4m2 has a cooling capacity
of 24W/°C. To limit the internal temperature increase to 10°C under these
conditions, the internal heat must not exceed 240W. If the actual internal
heat is 320W, however, the temperature in the cabinet rises by 13°C or
more. When this happens, the cooling capacity of the cabinet must be
improved using the heat exchanger described next.
3.4.2 If the temperature rise cannot be limited to 10°C by the cooling capacity
of the cabinet, a heat exchanger must be added. The heat exchanger
Cooling by Heat
forcibly applies the air from both the inside and outside of the cabinet to
Exchanger the cooling fin to obtain effective cooling. The heat exchanger enlarges
the surface area.
13
3. INSTALLATION B–63833EN/02
3.4.3
Heat Loss of Each Unit f indicates ”Applicable.”
DNC2 card f — 6W
FL–Net card f — 6W
DeviceNet card f — 5W
PROFIBUS card f — 6W
14
B–63833EN/02 3. INSTALLATION
3.5 The CNC has been steadily reduced in size using surface–mount and
custom LSI technologies for electronic components. The CNC also is
ACTION AGAINST designed to be protected from external noise. However, it is difficult to
NOISE measure the level and frequency of noise quantitatively, and noise has
many uncertain factors. It is important to prevent both noise from being
generated and generated noise from being introduced into the CNC. This
precaution improves the stability of the CNC machine tool system.
The CNC component units are often installed close to the parts generating
noise in the power magnetics cabinet. Possible noise sources into the
CNC are capacitive coupling, electromagnetic induction, and ground
loops.
When designing the power magnetics cabinet, guard against noise in the
machine as described in the following section.
3.5.1 The cables used for the CNC machine tool are classified as listed in the
following table:
Separating Signal
Lines Process the cables in each group as described in the action column.
Group Signal line Action
AC/DC relay
15
3. INSTALLATION B–63833EN/02
Cable for position and velocity Bind the cables in group C sepa-
feedback rately from group A, or cover
group C with an electromagnet-
Cable between the CNC and ic shield.
spindle amplifier
Separate group C as far from
Group B as possible.
Cable for the position coder
Be sure to perfrom shield pro-
Cable for the manual pulse gener- cessing in Subsec. 3.5.5.
ator
C
Cable between the CNC and the
CRT/MDI
NOTE
1 The groups must be 10 cm or more apart from one another
when binding the cables in each group.
2 The electromagnetic shield refers to shielding between
groups with grounded steel plates.
Cabinet
Duct
To operator’s
panel,
motor, etc.
Group A Group B, C
Cover
16
B–63833EN/02 3. INSTALLATION
3.5.2 The following ground systems are provided for the CNC machine tool:
Ground (1) Signal ground system (SG)
The signal ground (SG) supplies the reference voltage (0 V) of the
electrical signal system.
(2) Frame ground system (FG)
The frame ground system (FG) is used for safety, and suppressing
external and internal noises. In the frame ground system, the frames,
cases of the units, panels, and shields for the interface cables between
the units are connected.
(3) System ground system
The system ground system is used to connect the frame ground
systems connected between devices or units with the ground.
Machine
tool
Power
magnetics
cabinet
Distribution board
Notes on connecting the D Connect the signal ground with the frame ground (FG) at only one
ground systems place in the CNC control unit.
D Use the cable containing the AC power wire and the system ground
wire so that power is supplied with the ground wire connected.
17
3. INSTALLATION B–63833EN/02
3.5.3
Connecting the Signal
Ground (SG) of the Series 0i control unit
Control Unit
M3 (screw hole)
Ground cable (upper 2mm2) M4 (screw hole)
Ground plate of PE
the cabinet
Connect the 0 V line of the electronic circuit in the control unit with the
ground plate of the cabinet via the signal ground (SG) terminal.
The SG terminal is located below the main board of the control unit.
18
B–63833EN/02 3. INSTALLATION
Ground plate of PE
the cabinet
Connect the 0 V line of the electronic circuit in the control unit with the
ground plate of the cabinet via the signal ground (SG) terminal.
The SG terminal is located below the main board of the control unit.
19
3. INSTALLATION B–63833EN/02
MDI CRT
Approx. 15mm
M4 stud
MDI LCD
M4 stud
Approx. 17mm
Approx. 151mm
7.2″ LCD/MDI unit
LCD
M4 stud
Approx. 20mm
20
B–63833EN/02 3. INSTALLATION
Approx. 17mm
M3 screw hole
Approx. 60mm 8.4″ LCD unit
M4 stud
Approx. 17mm
Approx. 32mm
M4 stud
Approx. 30mm
Approx. 25mm
21
3. INSTALLATION B–63833EN/02
3.5.4 The AC/DC solenoid and relay are used in the power magnetics cabinet.
Noise Suppressor A high pulse voltage is caused by coil inductance when these devices are
turned on or off.
This pulse voltage induced through the cable causes the electronic circuits
to be disturbed.
Notes on selecting the D Use a spark killer consisting of a resistor and capacitor in series. This
spark killer type of spark killer is called a CR spark killer.(Use it under AC)
(A varistor is useful in clamping the peak voltage of the pulse voltage,
but cannot suppress the sudden rise of the pulse voltage. FANUC
therefore recommends a CR spark killer.)
D The reference capacitance and resistance of the spark killer shall
conform to the following based on the current (I (A)) and DC
resistance of the stationary coil:
1) Resistance (R) : Equivalent DC resistance of the coil
I2 I2
2) Capacitance (C) : to (µF)
10 20
I : Current at stationary state of the coil
R C
Equivalent circuit of the spark killer
AC Spark killer
relay
Motor
Spark killer
NOTE
Use a CR–type noise eliminator. Varistor–type noise
eliminators clamp the peak pulse voltage but cannot
suppress a sharp rising edge.
Diode
Use a diode which can withstand a
voltage up to two times the applied
DC relay voltage and a current up to two times
the applied current.
22
B–63833EN/02 3. INSTALLATION
3.5.5 The CNC cables that require shielding should be clamped by the method
Cable Clamp and shown below. This cable clamp treatment is for both cable support and
proper grounding of the shield. To insure stable CNC system operation,
Shield Processing follow this cable clamp method.
Partially peel out the sheath and expose the shield. Push and clamp by
the plate metal fittings for clamp at the part. The ground plate must be
made by the machine tool builder, and set as follows :
Ground plate
Cable
Metal fittings
for clamp
40mm – 80mm
23
3. INSTALLATION B–63833EN/02
ÇÇ
Machine side
installation
ÇÇ board
ÇÇ
Control unit
ÇÇ
ÇÇ
ÇÇ
ÇÇ
ÇÇ
ÇÇ
ÇÇ
ÇÇ
Ground plate
ÇÇ
ÇÇ
ÇÇ
Metal fittings
ÇÇ
ÇÇ
for clamp
ÇÇ
Shield cover
Ground terminal
(grounded)
For the ground plate, use a metal plate of 2 mm or thicker, which surface
is plated with nickel.
24
B–63833EN/02 3. INSTALLATION
Ground
8mm plate
12mm
20mm
Max. 55mm
28mm
6mm
17mm
25
3. INSTALLATION B–63833EN/02
3.6
CONTROL UNIT
Space for air flow, and access area for fan replacement
Single–slot rack: Approx. 65
Two–slot rack: Approx. 120
ÊÊÊÊÊÊ ÊÊÊÊÊÊÊÊÊ
ÅÅ
ÊÊ
ÊÊÊÊÊÊ ÊÊÊÊÊÊÊÊÊ A
50
30
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
Access space
for spare
connector
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
C Spare connector
380
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÅÅ
ÊÊ
ÊÊÊÊÊÊ
ÊÊÊÊÊÊ ÊÊÊÊÊÊÊÊÊ
ÊÊÊÊÊÊÊÊÊ
ÊÊÊÊÊÊ ÊÊÊÊÊÊÊÊÊ
50
B B
80
Unit: mm
Sufficient space for replacing a
printed circuit board is required.
Fig. 3.6.1
26
B–63833EN/02 3. INSTALLATION
0i–B 0i Mate–B
Unit: mm
27
3. INSTALLATION B–63833EN/02
Unit : mm
28
B–63833EN/02 3. INSTALLATION
3.8
CONNECTOR
LAYOUT DIAGRAM
Machine interface
9” CRT connector connector
(5.1) (8)
Servo amplifier
connector
(7.1)
Fig.3.8 (a)
29
3. INSTALLATION B–63833EN/02
Memory back up
battery
(4.4)
9” CRT connector
(5.1)
LCD connector
(5.1)
Power supply
connector
(4.3)
Servo amplifier
connector
(7.1)
Fig.3.8 (b)
30
B–63833EN/02 3. INSTALLATION
Ethernet board
connector (13)
DeviceNet board
DeviceNet board
connector (13)
PROFIBUS board
PROFIBUS board
connector (13)
FL–net board
FL–net board
connector (13)
Fig.3.8 (c)
NOTE
The numbers in parentheses () in the figures are keyed to
the item numbers of the descriptions in this manual. The
numbers in brackets [] in the figures are connector numbers.
31
3. INSTALLATION B–63833EN/02
HSSB optical
connector (12)
DNC2 board
RS–232–C
connector (11)
Fig.3.8 (d)
NOTE
The numbers in parentheses () in the figures are keyed to
the item numbers of the descriptions in this manual. The
numbers in brackets [] in the figures are connector numbers.
32
B–63833EN/02 4. POWER SUPPLY CONNECTION
33
4. POWER SUPPLY CONNECTION B–63833EN/02
4.1 This section explains the connection of power supply for Series 0i/Series
0i Mate control unit.
GENERAL
34
B–63833EN/02 4. POWER SUPPLY CONNECTION
4.2
TURNING ON AND
OFF THE POWER TO
THE CONTROL UNIT
4.2.1 Supply power (24VDC) to the control uint of Series 0i/Series 0i Mate
Power Supply for the from an external sources.
Control Unit Provide ON/OFF circuit A for turning the AC power on and off or
ON/OFF circuit B for turning 24 VDC on and off outside the unit as
shown in Fig. 4.2.1 (a). It is recommended that the AC power be turned
on and off (ON/OFF circuit A).
Main circuit Magnetic AC line Servo converter Servo inverter CNC control unit
breaker contractor filter
3–phase 200
200 V AC VAC for power
line
Single–phase
200 VAC for
control line 24 VDC
input
35
4. POWER SUPPLY CONNECTION B–63833EN/02
ON/OFF circuit B For example, “ON/OFF circuit” is as follows : (Fig. 4.2.1 (b) )
(example) Select the circuit devices, in consideration of its capacity.
+24V +24V
ry1 OUTPUT 24 VDC
RY1 The power rating is the
DC INPUT sum of power requirements
24 V on the load side.
0V 0V
ry1
RELAY
OFF COM ON DIODE COIL RELAY CONTACT
B A CONTACT
CONTACT
POWER ON/OFF SWITCH
36
B–63833EN/02 4. POWER SUPPLY CONNECTION
Instantaneous Instantaneous
interruption interruption
(–100%) (–50%)
10mS 20mS
AC input voltage
26.4V
Output voltage
21.6V Abrupt
load
change
Output current
0A
Fig. Example of ripple voltage and noise due to switching power supply
26.4V
Noise
Ripple
Allowable range
voltage
Noise
21.6V
37
4. POWER SUPPLY CONNECTION B–63833EN/02
S Notes to take when the When the vertical axis exists, select the DC power supply that has a long voltage
vertical axis exists hold time to decrease the amount of vertical axis falling during power–off
(including a power failure).
If the operating voltage drops to less than or equal to 21.6V, the CNC releases
servo activation. Therefore, when the hold time for 24 VDC during AC
power–off is too short, servo activation is released before the breaks are applied
because some peripheral circuit detects power–off. This may increase the
amount of vertical axis falling.
Generally, a power supply with sufficient power capacity tends to increase the
hold time during power–off.
Example 2
NOTE
The rectifier circuit means a circuit using diodes for
full–wave rectification.
Regulated
AC input power CNC unit
supply
Device with
remarkable
load fluc-
tuations
38
B–63833EN/02 4. POWER SUPPLY CONNECTION
Example 2
Regulated
AC input power CNC unit
supply
Device with
large rush
current
On
Power to the CNC
Off
t1 t2
Power to units On
(including the
Power Mate) Off
39
4. POWER SUPPLY CONNECTION B–63833EN/02
β amplifier
with an I/O link
40
B–63833EN/02 4. POWER SUPPLY CONNECTION
4.2.3 Turn on the power to each unit in the following order or all at the same
Procedure for Turning time.
On the Power
1. Power to the overall machine (200 VAC)
2. Servo amplifier control power supply (200 VAC)
3. Power to the slave I/O units connected via the I/O link,
power to the display unit (24VDC),
the CNC control unit,
power to the separate detector (scale),
and power to the separate detector interface unit (24VDC)
“Turning on the power to all the units at the same time” means completing
the power–on operations in 1 and 2 above within 500 ms of performing
power–on in 3.
As for a CNC display unit with PC functions, no specific power turn–on
sequence for the CNC control unit is required.
D If the power only to the control unit of the CNC is turned on without
turning the power to the CNC display unit with PC functions on, the
control unit of the CNC does not start up normally.
D If the power only to the CNC display unit with PC functions is turned
on without turning the power to the control unit of the CNC on
conversely, the units do not start up normally.
Do not disconnect the battery for memory backup (3 VDC) or the battery
for the separate absolute pulse coders (6 VDC) regardless of whether the
power to the control unit is on or off. If batteries are disconnected when
the power to the control unit is turned off, current data stored in the control
unit for the pulse coders, parameters, programs etc, are lost.
Make sure that the power to the control unit is on when replacing batteries.
See Section 4.4.1 for how to replace the batteries for memory backup.
CAUTION
The maintenance rotary switch must be always set to 0 (set
to 0 at shipping from factory).
Changing this setting may cause the contents of memory to
be lost.
41
4. POWER SUPPLY CONNECTION B–63833EN/02
4.2.4 Turn off the power to each unit in the following order or all at the same
Procedure for Turning time.
Off the Power
1. Power to the slave I/O units connected via the I/O link,
power to the display unit (24VDC),
the CNC control unit (24 VDC),
and power to the separate detector interface unit (24 VDC)
2. Servo amplifier control power supply (200 VAC)
and power to the separate detector (scale)
3. Power to the overall machine (200 VAC)
“Turning off the power to all units at the same time” means completing
the power–off operations in 2 and 3 above within 500 ms before the
power–off operation described in 1 above. If the power to the units
indicated in 2 or 3 is turned off other than within 500 ms of the power in
1 being turned off, alarm information is left in the NC.
The power–off sequence for an CNC display unit with PC functions is
undefined.
CAUTION
When the CNC display unit with PC functions is used, the
OS must be shut down before the power to the control unit
is turned off. Be careful not to turn off the power while the
hard disk is being accessed or before the OS has
terminated; otherwise, the hardware contents may be
destroyed.
42
B–63833EN/02 4. POWER SUPPLY CONNECTION
Cable
CP1A
AMP Japan
1–178288–3 (housing)
1–175218–5 (Contact) External power
43
4. POWER SUPPLY CONNECTION B–63833EN/02
4.4
BATTERY
4.4.1 Part programs, offset data, and system parameters are stored in CMOS
Battery for Memory memory in the control unit. The power to the CMOS memory is backed
up by a lithium battery mounted on the front panel of the control unit. The
Backup (3VDC) above data is not lost even when the main battery goes dead. The backup
battery is mounted on the control unit at shipping. This battery can
maintain the contents of memory for about a year.
When the voltage of the battery becomes low, alarm message “BAT”
blinks on the CNC display and the battery alarm signal is output to the
PMC. When this alarm is displayed, replace the battery as soon as
possible. In general, the battery can be replaced within two or three
weeks, however, this depends on the system configuration.
If the voltage of the battery becomes any lower, memory can no longer
be backed up. Turning on the power to the control unit in this state causes
system alarm 935 (ECC error) to occur because the contents of memory
are lost. Clear the entire memory and reenter data after replacing the
battery.The power to the control unit must be turned on when the battery
is replaced. If the battery is disconnected when the power is turned off,
the contents of memory are lost.
Observe the following precautions for lithium batteries:
WARNING
If an unspecified battery is used, it may explode.
Replace the battery only with the specified battery
(A02B–0200–K102.)
44
B–63833EN/02 4. POWER SUPPLY CONNECTION
Battery connector
Lithium battery
4 Remove the battery from the front panel of the control unit.
First detach the connector, then remove the battery from the battery
case.
5 Replace the battery and then reconnect the connector.
CAUTION
Steps 3 to 5 must performed within 10 minutes. Note that
all data in memory is lost when the battery is kept removed
for extended time.
45
4. POWER SUPPLY CONNECTION B–63833EN/02
4.4.2 If the voltage of a battery drops, the screen on the LCD flashes. (If a fan
Batteries for CNC alarm is issued, the screen on the LCD also flashes.) If this status occurs,
replace the battery as soon as possible (within 1 week). FANUC
Display Unit with PC recommends that each battery be replaced periodically (once a year)
Functions (3VDC) regardless of whether a battery alarm is issued.
The BIOS settings are usually preserved as long as the battery is replaced
according to the following procedure. If they are lost, the following
message is displayed when the power is turned on:
251: System CMOS checksum bad – Default configuration used.
After this, the default BIOS settings are loaded, and the unit restarts
automatically. Before starting machining, check that the current BIOS
settings of the CNC display unit with PC functions in use have been
changed from the default BIOS settings, and resume your settings as
required.
(1) After keeping the CNC display unit with PC functions powered for at
least 5 seconds, turn it off, and enable work to be done from the rear,
for example, by removing the battery section from the panel.
(2) Remove the connector from the lithium battery, and take the battery
out from the battery holder.
(3) Attach the connector (BAT1) to a new battery within 5 minutes, and
put the battery in the battery holder.
(4) Put the CNC display unit with PC functions back into the previous
place.
(5) Turn the power on, and check that no BIOS parameter is lost (no error
is detected at start–up).
NOTE
Be sure to install a new battery within 5 minutes after the old
one is removed from the connector.
46
B–63833EN/02 4. POWER SUPPLY CONNECTION
Battery holder
Lithium battery
A02B–0200–K102
Connector
(BAT1)
4.4.3 One battery unit can maintain current position data for six absolute pulse
coders for a year.
Battery for Separate
When the voltage of the battery becomes low, APC alarms 3n6 to 3n8 (n:
Absolute Pulse Coders axis number) are displayed on the LCD display. When APC alarm 3n7
(6VDC) is displayed, replace the battery as soon as possible. In general, the battery
should be replaced within one or two weeks, however, this depends on the
number of pulse coders used.
If the voltage of the battery becomes any lower, the current positions for
the pulse coders can no longer be maintained. Turning on the power to
the control unit in this state causes APC alarm 3n0 (reference position
return request alarm) to occur. Return the tool to the reference position
after replacing the battery.
Therefore, FANUC recommends that the battery be replaced once a year
regardless of whether APC alarms are generated.
See Section 7.1.3 for details of connecting the battery to separate absolute
pulse coders.
47
4. POWER SUPPLY CONNECTION B–63833EN/02
Replacing batteries Obtain four commercially available alkaline batteries (size D).
(1) Turn on the power to the machine (Series 0i/0i Mate).
(2) Loosen the screws of the battery case, and remove the cover.
(3) Replace the dry batteries in the case.
Note the polarity of the batteries as shown in the figure below (orient
two batteries one way and the other two in the opposite direction).
Screws
Å
Å
Å ÇÇÅ
Å
Ç ÇÇ
Å Cover
Å ÅÅ Ç
Å
(4) After installing the new batteries, replace the cover.
(5) Turn off the power to the machine (Series 0i/0i Mate).
WARNING
If the batteries are installed incorrectly, an explosion may
occur. Never use batteries other than the specified type
(Size D alkaline batteries).
CAUTION
Replace batteries while the power to the i Series CNC is on.
Note that, if batteries are replaced while no power is
supplied to the CNC, the recorded absolute position is lost.
4.4.4 The battery for the absolute pulse coder built into the motor is installed
in the servo amplifier. For how to connect and replace the battery, refer
Battery for Absolute
to the following manuals:
Pulse Coder Built into
D FANUC SERVO MOTOR αi series Maintenance Manual
the Motor (6VDC)
D FANUC SERVO MOTOR β series Maintenance Manual
D FANUC SERVO MOTOR β series (I/O Link Option) Maintenance
Manual
48
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
49
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.1
CONNECTION TO THE
DISPLAY UNIT/
MDI UNIT
5.1.1 The following display units can be connected to the Series 0i/0i Mate.
Outline
For 9”CRT/MDI
9″CRT/MDI unit
CNC
Subsec. 5.1.2 9″CRT Subsec. 5.1.2
JA1 CN1 CN2 24VDC
Soft key
CK2
MDI
Subsec. 5.1.4
JA2 CK1
7.2″LCD/MDI unit
8.4″LCD/MDI unit
CNC
7.2″LCD
8.4″LCD
Subsec. 5.1.3 Subsec. 5.1.3
COP20A COP20B CP1A 24VDC
CK1 CK2
MDI
50
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
JA2
MDI unit
51
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.1.2
9″ CRT Display Unit
Interface
JA1 CN1
(PCR–EV20MDT) (MR–20RM)
01 VDR 11 1 VDR 14
8 0V
02 0V 12 VSYNC 2 HSYNC 15
9 0V
03 VDG 13 3 VSYNC 16
10 0V
04 0V 14 0V 4 VDG 17 (0V)
11 0V
05 VDB 15 5 VDB 18 (0V)
12 0V
06 0V 16 0V 6 19
13
07 17 7 20
08 18 HSYNC
09 19
10 20
1 CN2
1 +24V 2 Cable side
CP1B 2 0V 3 (0V) JAPAN FCI
Cable side 3 4 0V SMS6PN–5 (Housing)
JAPAN AMP 5 +24V RC16M–23TB or RC16M
2–178288–3 (Housing) (contact)
6 (+24V)
1–175218–5 (contact)
Connection of
VIDEO Signal Cable
JA1 CN1
HIROSE FI40A–20S–CV5 (Connector) HONDA MR20pins/female
52
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.1.3
Various LCD Units
Interface
D Connection between the An optical fiber cable is used to make the connection between the CNC
CNC control unit and control unit and LCD unit. For details of the optical fiber cable, see
LCD unit Appendix D.
D Connection of a power Feed power to the LCD unit from an external 24 VDC power supply.
supply to the LCD unit
LCD unit External power supply
CP1A
1 +24V 24 VDC regulated
2 0V power supply
3 24 VDC ±10%
Cable
CP1A
AMP Japan
1–178288–3 (housing)
1–175218–5 (contact) External power supply
+24V (1) Select a cable that
0V (2) matches the pins of the
external power supply.
Part of the 24 VDC power input to CP1A can be taken out from CP1B by
branching. CP1B should be connected as shown below. In this case, the
rating of the external 24 VDC power supplied to CP1A must be the sum
of the power consumed within the control unit and that supplied to
external equipment via CP1B. Up to 1.0 A can be supplied to the external
equipment.
CP1B
1 +24V
2 0V
3
Cable
CP1B
AMP Japan
2–178288–3 (housing)
1–175218–5 (contact)
External power supply
+24V (1) Select a cable that
0V (2) matches the pins of the
external power supply.
53
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.1.4
Connection to the
Standard MDI Unit
JA2 CK1
01 :KEY00 11 :KEY01 01 :KEY00 11 :KEY01
02 :KEY02 12 :KEY03 02 :KEY02 12 :KEY03
03 :KEY04 13 :KEY05 03 :KEY04 13 :KEY05
04 :KEY06 14 :KEY07 04 :KEY06 14 :KEY07
05 :COM00 15 :COM01 05 :COM00 15 :COM01
06 :COM02 16 :COM03 06 :COM02 16 :COM03
07 :COM04 17 :COM05 07 :COM04 17 :COM05
08 :COM06 18 :COM07 08 :COM06 18 :COM07
09 :COM08 19 :COM09 09 :COM08 19 :COM09
10 :COM10 20 :COM11 10 :COM10 20 :COM11
Cable
JA2 CK1
Honda PCR connector Honda PCR connector
SHIELD
GROUND
PLATE
54
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.2
VARIED MDI KEY
SWITCH
D 9″CRT/MDI unit
(T series)
D 7.2″LCD/MDI unit
(T series)
D 8.4″LCD/MDI unit
(T series)
D Stand–alone type small
MDI unit (T series)
English display
Symbol display
55
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
D 9″CRT/MDI unit
(M series)
D 7.2″LCD/MDI unit
(M series)
D 8.4″LCD/MDI unit
(M series)
D Stand–alone type small
MDI unit (M series)
English display
Symbol display
56
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
D Stand–alone type
full–key MDI unit
(T series)
English display
Symbol display
57
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
D Stand–alone type
full–key MDI unit
(M series)
English display
Symbol display
58
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.3
CONNECTING I/O
DEVICES
5.3.1 I/O devices are used for inputting various data such as CNC programs and
General parameters from external devices to the CNC or outputting data from the
CNC to external devices.
The Handy File is one of the I/O devices for the Series 0i. The interface
for I/O devices complies with RS–232–C. The Series 0i can therefore be
connected to devices which have an RS–232–C interface.
59
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.3.2
Connecting I/O Devices
R232–1
JD5A
R232–2
JD5B
Handy File
60
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.3.3
RS–232–C Serial Port
CNC
RELAYING CONNECTOR
JD5A, JD5B (DBM–25S)
(PCR–EV20MDT) 1 FG
14
1 RD 11 SD 2 SD
15
2 0V 12 0V 3 RD
16
3 DR 13 ER 4 RS
17
4 0V 14 0V 5 CS
18
5 CS 15 RS 6 DR
19
6 0V 16 0V 7 SG
20 ER
7 CD 17 8 CD
21
8 0V 18 9
22
9 19 +24V 10
23
10 +24V 20 11
24
12
25 +24V
13
CABLE WIRING
1 3
RD RD
2
0V
3 6
DR DR
4
0V
5 5
CS CS
6
0V
7 8
CD CD
8
0V
9
10
+24V
11 2
SD SD
12
0V
13 20
ER ER
14
0V
15 4
RS RS
16 7
0V SG
17
18
19 25
+24V +24V
20 1
SHIELD
GND
GROUND PLATE
RECOMMENDED CABLE MATERIAL
A66L–0001–0284#10P(#28AWG 10–pair)
RECOMMENDED CABLE SPECIFICATION (PUNCH PANEL)
<Narrow width type>
A02B–0120–C191 (1m)
A02B–0120–C192 (2m)
A02B–0120–C193 (5m)
<Wide width type>
A02B–0120–C181 (1m)
A02B–0120–C182 (2m)
A02B–0120–C183 (5m)
61
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.3.4
RS–232–C Interface
Specification
RS–232–C Interface Generally signals as follows are used in RS–232–C interface.
signals
CNC
Output
SD (Send data)
Input
RD (Recieve data)
SG (Signal ground)
FG (Frame ground)
62
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
CS 106 Input Sending When both this signal and the DR sig-
permitted nal are set, the NC can send data. If ex-
ternal device processing is delayed by
a punching operation, etc., NC data
sending can be stopped by turning off
this signal after sending two charac-
ters, including the data being sent cur-
rently. If this signal will not be used,
make sure to strap this signal circuit to
the RS signal circuit.
SG 102 Signal
grounding
FG 101 Frame
grounding
NOTE
Signal on/off state is defined as follows;
–3V or lower +3V or higher
Function OFF ON
Signal Condition Marking Spacing
63
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
Transmission Method of
RS–232–C interface
Start–stop Generally, two transmission methods are available at the serial interface.
Series 0i use the start–stop method. With this method, start and stop
signals are output before and after each data bit.
b1 b2 b3 b4 b5 b6 b7 b8
NOTE
The listed control codes are used for both EIA and ISO.
64
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
Table 5.3.4
ISO code EIA code
Meaning
Character 8 7 6 5 4 3 2 1 Character 8 7 6 5 4 3 2 1
0 f f F 0 f F Numeral 0
1 f f f F f 1 F f Numeral 1
2 f f f F f 2 F f Numeral 2
3 f f F f f 3 f F f f Numeral 3
4 f f f F f 4 F f Numeral 4
5 f f F f f 5 f F f f Numeral 5
6 f f F f f 6 f F f f Numeral 6
7 f f f F f f f 7 F f f f Numeral 7
8 f f f f F 8 f F Numeral 8
9 f f f F f 9 f f F f Numeral 9
A f F f a f f F f Address A
B f F f b f f F f Address B
C f f F f f c f f f F f f Address C
D f F f d f f F f Address D
E f f F f f e f f f F f f ? Address E
F f f F f f f f f f F f f Address F
G f F f f f g f f F f f f Address G
H f f F h f f f F Address H
I f f f F f i f f f f F f Address I
J f f f F f j f f F f Address J
K f f F f f k f f F f Address K
L f f f F f l f F f f Address L
M f f F f f m f f F f Address M
N f f F f f n f F f f Address N
O f f f F f f f o f F f f Address O
P f f F p f f F f f f Address P
Q f f f F f q f f f F Address Q
R f f f F f r f f F f Address R
S f f F f f s f f F f Address S
T f f f F f t f F f f Address T
U f f F f f u f f F f Address U
V f f F f f v f F f f Address V
W f f f F f f f w f F f f Address W
X f f f f F x f f F f f f Address X
Y f f f F f y f f f F Address Y
Z f f f F f z f f F f Address Z
DEL f f f f f F f f f Del f f f f F f f f :
NUL F Blank F :
BS f f F BS f f F f :
HT f F f Tab f f f F f f :
LF or NL f F f CR or EOB f F
CR f f F f f :
SP f f F SP f F :
% f f F f f ER f F f f
( f f F ( 2–4–5 ) f f F f
) f f f F f ( 2–4–7 ) f f F f
+ f f F f f + f f f F :
– f f F f f – f F –
: f f f F f
/ f f f F f f f / f f F f
. f f F f f . f f f F f f
# f f F f f :
$ f F f :
& f f F f f & f F f f :
’ f F f f f :
: f f f F f :
, f f f F f , f f f F f f :
; f f f f F f f :
< f f f F f :
= f f f f F f f :
> f f f f F f f :
? f f f F f f f :
@ f f F :
” f F f :
65
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
NOTE
1 When the external device is equipped with an ISO/EIA
converter, the following items must be noted in Table
5.3.4(a).
Condition1
Left parenthesis “(”of the ISO code punches holes at bits 2, 4, and 5
when used in the EIA code.
Right parenthesis “)”of the ISO code punches holes at bits 2, 4, and 7
when used in the EIA code.
Condition2
EIA code CR is LF in ISO code.
Condition3
EIA code O is : in ISO code.
NOTE
2 Control codes DC1 to DC4 are transmission codes output
from the NC. So they need not to be punched on the NC
tape.
66
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
ER(Output)
RS(Output)
DC1 CD3 DC1 DC3
SD(Output)
ER code
RD(Input)
DR(Input)
CS(Input)
Up to 10 characters
1ms or longer
67
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
ER(Output)
RS(Output)
DC2 DC4
SD(Output)
RD(Input)
CS(Input)
Fig.A
ER(Output)
RS(Output)
DC2 DC4
SD(Output)
DC3 DC1
RD(Input)
Within 10 characters
DR(Input)
CS(Input)
1ms or longer
Fig.B
68
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
Connection between
RS–232–C interface and
I/O devices
CNC I/O device side
SD SD
RD RD
RS RS
CS CS
ER ER
DR DR
CD CD
SG SG
0V
FG FG
69
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.3.5
FANUC Handy File
Connection
NOTE
1 Machine tool builder shall furnish relay connector and relay
cable.
2 Use a totally shielded cable for the signal cable.
Recommended cable specification:
A66L–0001–0284#10P
3 Open all terminals other than illustrated.
4 Set suitable parameters on reader/puncher interface for
FANUC Handy File. The baud rate is 4800 baud in
standard.
5 Connect the FANUC Handy File to either JD5A or JD5B. Do
not use both pins; the power capacity may exceed that of
+24V and blow the fuse.
70
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.4
CONNECTING THE
MANUAL PULSE
GENERATOR
5.4.1 Manual pulse generators are used to manually move an axis in the handle
General feed mode.
This subsection describes manual pulse generators for the Series 0i. See
Section 9.5 for the Series 0i Mate.
Series 0i
control unit
MPG
JA3B
71
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.4.2
Connection to Manual
Pulse Generators CNC Manual Pulse Generator
Cable connection
Manual Pulse
T.B.
Generator
#1
1 7 RD HA1 5 HA1
HA1 2 7 WH 6
HB1 HB1 HB1
9 5 RD 3
+5V +5V +5V
12 2 BK 4
0V 0V 0V
#2
3 8 RD HA2 5 HA2
HA2 4 8 BK 6
HB2 HB2 HB2
18 4 RD 3
+5V +5V +5V
14 3 BK 4
0V 0V 0V
#3
5 9 BK 5
HA3 HA3
HA3 6 9 WH 6
HB3 HB3 HB3
20 6 RD 3
+5V 16 1 BK +5V +5V
4
0V 0V 0V
shield
Ground Plate
Cable Wires
72
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.4.3 Manual pulse generators are supplied with 5 VDC power the same as
Cable Length When pulse coders. The drop in voltage due to cable resistance must not exceed
0.2V (on 0V and 5V lines in total).
Only One Manual Pulse
Generator is Used 0.2y
0.1 R 2L where 0.1 :Power supply current for the
manual pulse generator = 0.1 A
m R : Wire resistance per unit length [Ω/m]
m : Number of 0–V wires
Therefore, (= number of 5–V wires)
L : Cable length [m]
m
Lx
R
73
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.5
CONNECTING THE
HIGH–SPEED SKIP
(HDI)
5.5.1
General
High–speed skip
(HDI)
Switch
74
B–63833EN/02 5. CONNECTION TO CNC PERIPHERALS
5.5.2
Connection to the
CNC
High–speed Skip (HDI)
JA40
PCR–EV20MDT
1 HDI0 11
2 0V 12
3 13
4 14
5 (ES)0V 15
6 16
7 (SVC) 17
8 (ENB1) 18
9 (ENB2) 19
10 20
NOTE
Leave connector pins unconnected if they are not intended
for use.
Cable connections
JA40
1
HDI0
2
0V
7
8
9
10
Shield
Ground plate
75
5. CONNECTION TO CNC PERIPHERALS B–63833EN/02
5.5.3
Input Signal Rules for
the High–speed Skip
(HDI)
Circuit configuration
CNC
VH/VL
SHIELD
0V
11 max mA Vin = 10 V
NOTE
1 The plus (+) sign of IiH/IiL represents the direction of flow
into the receiver. The minus (–) sign of IiH/IiL represents the
direction of flow out of the receiver.
2 The high–speed skip signal is assumed to be 1 when the
input voltage is at the low level and 0 when it is at the high
level.
3 The input level for the CNC receiver is high when the circuit
is open. So, the input level for the external driver must be
low.
76
B–63833EN/02 6. SPINDLE CONNECTION
6 SPINDLE CONNECTION
77
6. SPINDLE CONNECTION B–63833EN/02
The figure below shows the spindle–related connections. Note that the
number of connectable spindles depends on the model. So, see the tables that
follow the figure below.
Position
coder
Analog output f f f
Position coder f f
78
B–63833EN/02 6. SPINDLE CONNECTION
6.1
SERIAL SPINDLE
6.1.1
Connection of One to
Two Serial Spindles CNC Spindle amplifier module
JA41 JA7B
PCR–EV20MDT (PCR–E20MDT)
1 SIN 11 1 SIN 11 0V
2 *SIN 12 0V 2 *SIN 12 0V
3 SOUT 13 3 SOUT 13 0V
4 *SOUT 14 0V 4 *SOUT 14 0V
5 [ ] 15 [ ] 5 15 0V
6 [ ] 16 0V 6 16 0V
7 [ ] 17 [ ] 7 17
8 [ ] 18 (+5V) 8 18 (+5V)
9 (+5V) 19 [ ] 9 (+5V) 19
10 [ ] 20 (+5V) 10 20 (+5V)
NOTE
1 When an optical I/O link cable is used for connection
between the NC and a spindle amplifier, the +5V signals
indicated in parentheses are used to feed power to the
optical I/O link adapter. Do not connect these signals when
an optical cable is not used. The signals in brackets ([ ])
are used when a position coder is used with an analog
spindle is used.
2 The second serial spindle is connected as a branch from the
spindle amplifier module.
79
6. SPINDLE CONNECTION B–63833EN/02
Cable connection
*SOUT 4 2 *SIN
CNC
SIN 1 3 SOUT Spindle
amplifier
*SIN 2 4 *SOUT module
12,14,16 12,14,16
NOTE
In any of the following cases, make a connection via an
optical fiber cable by using an optical I/O link adapter:
D When the cable is 20 m or longer
D When the power magnetics cabinet containing a spindle
amplifier cannot be connected with the operator’s panel
cabinet containing a CNC control unit via a ground wire
with a cross–sectional area of 5.5 mm2 or more
D When the cable is subject to significant noise. For
example, when there is a strong electromagnetic noise
source such as a welding machine near the cable, or
when the cable runs in parallel with a power line or power
magnetics cable that can generate noise.
80
B–63833EN/02 6. SPINDLE CONNECTION
6.2
ANALOG SPINDLE CNC
INTERFACE Signal Name Description
SVC, ES Spindle command voltage
JA40 and common line
PCR–EV20MDT ENB1, ENB2 Spindle enable signal (Note 1)
1 HDI0 11
2 (0V) 12
3 13
4 14
5 ES 15
6 16
7 SVC 17
8 ENB1 18
9 ENB2 19
10 20
SVC 7 DA2
ES 5 E
ENB1 8 SHIELD
ENB2 9
GROUNDING PLATE
NOTE
1 Signals ENB1 and 2 turn on when the spindle command
voltage is effective. These signals are used when the
FANUC Analog Spindle Servo Unit is used.
2 The analog output ratings are as follows:
Output voltage: "10 V
Output current: 2 mA (maximum)
Output impedance: 100 ohms
3 The parenthesized signals are used for the high–speed skip
function (HDI).
81
6. SPINDLE CONNECTION B–63833EN/02
6.3
POSITION CODER CNC
INTERFACE Signal Name Description
JA41
SC, :SC Position coder phase C signals
PCR–E20MDT
PA, :PA Position coder phase A signals
1 ( ) 11
PB, :PB Position coder phase A signals
2 ( ) 12 0V
3 ( ) 13 SOUT, :SOUT Serial spindle signals (Note)
4 ( ) 14 0V SIN, :SIN
5 PA 15 SC
6 :PA 16 0V
7 PB 17 :SC
8 :PB 18 +5V
9 +5V 19 ( )
10 ( ) 20 +5V
POSITION CODER
CNC
5
PA A (PA)
6
:PA N (:PA)
7
PB 8 C (PB)
:PB R (:PB)
SC 15 B (:PZ)
17
:SC P (:PZ)
9,18,20
+5V H
12,14,16
0V K
SHIELD
GROUNDING
PLATE
RECOMMENDED CABLE–SIDE CONNECTOR
PCR–E20FA (Honda Tsushin Kogyo Co., Ltd.)
FCN–247J020–G/E (Fujitsu, Ltd.)
52622–2011 (Molex Japan Co., Ltd.)
RECOMMENDED CABLE SPECIFICATION:
A66L–0001–0286 (#20AWG 6 + #24AWG 3),
MAX. LENGTH 20 m
NOTE
1 The signals for a serial spindle are parenthesized. These
signals are not used for an analog spindle.
2 As the connector on the cable side, the solder–type 15–pin
connector (FI40B–2015S, or conventional FI40–2015S)
manufactured by Hirose Electric cannot be used.
82
B–63833EN/02 7. SERVO INTERFACE
7 SERVO INTERFACE
83
7. SERVO INTERFACE B–63833EN/02
7.1
CONNECTION TO
THE SERVO
AMPLIFIERS
Servo amplifier
FSSB
COP10A
84
B–63833EN/02 7. SERVO INTERFACE
7.1.1 This chapter describes how to connect the servo units to the Series 0i/0i
General Mate. For details of the connection of the Servo amplifier αi series, refer
to the Servo Amplifier αi series Descriptions (B–65282EN).
7.1.2
Interface to the Servo
Control unit
Amplifiers
Servo amplifier modules
COP10A COP10B
COP10A
COP10B
Optical fiber cable
COP10A
Series 0i Mate–TB: Maximum 2 axes
Series 0i Mate–MB: Maximum 3 axes COP10B
Series 0i–TB/MB: Maximum 4 axes
COP10A
COP10B
Cable Length Restriction
Within 100 m between units COP10A
Total length within 500 m
The connection between the CNC control unit and the servo amplifiers
should use only one optical fiber cable, regardless of the number of
controlled axes. See APPENDIX D for details on the optical fiber cable.
In the control unit, the COP10A connector is placed on the servo card
installed on the main board.
85
7. SERVO INTERFACE B–63833EN/02
7.1.3
Separate Detector
Interface
CP11A
Control unit or
the previous–stage servo
amplifier module
Linear scale
86
B–63833EN/02 7. SERVO INTERFACE
CNC
ÔÔ COP10A
ÔÔ
ÔÔ
ÔÔ
COP10B
COP10A
ÔÔ
|
ÔÔ COP10B
ÔÔ
Optical fiber cable
COP10A
Ô ÔÔ
Ô ÔÔ
COP10B JF101 Linear scale axis 1
Ô ÔÔ
COP10A JF102 Linear scale axis 2
24VDC
ÔÔ
CP11A JF103 Linear scale axis 3
ÔÔ
JF104 Linear scale axis 4
CNF1 JA4A Battery for absolute
separate detector
87
7. SERVO INTERFACE B–63833EN/02
7.1.4 The interface unit can feed 0.35 A (5 V) to each separate detector.
Separate Detector Item Specification
Interface Unit
Power supply capacity Voltage 24 VDC ±10%
Specification Current 0.9 A (basic unit only)
1.5 A (basic unit + expansion unit)
7.1.5 Power to the separate detector interface unit should be supplied from an
external 24 V DC power supply.
Connection of Power
Supply
Separate detector interface unit External power supply
CP11A
1 +24V 24 V DC regulated
2 0V power supply
3 24 V DC "10%
Cable
CP11A
AMP JAPAN
1–178288–3 (Housing) External power
1–175218–5 (Contact) supply
Select a connector that
+24V (1) matches the pin layout
0V (2) of the external power
supply.
88
B–63833EN/02 7. SERVO INTERFACE
7.1.6
Linear Scale Interface Separate detector interface unit
Linear scale
JF101 to JF104
(PCR–EV20MDT)
1 PCA 11
2 *PCA 12 0V
3 PCB 13
4 *PCB 14 0V
5 PCZ 15
6 *PCZ 16 0V
7 (+6V) 17
+6V and REQ are for separate
absolute pulse coders.
8 (REQ) 18 +5V
9 +5V 19
10 20 +5V
Cable wiring
1
PCA PCA
2
*PCA *PCA
3
PCB PCB
4
*PCB *PCB
5
PCZ PCZ
6
*PCZ *PCZ
9
+5V +5V
18
+5V +5V
20
+5V +5V
12
0V 0V
14
0V 0V
16
0V 0V
SHIELD
GROUNDING PLATE
NOTE
The +5V signals above can be used to feed power to the
linear scales. The supply current per linear scale is 0.35 A
maximum.
Minimum tolerance to 5 V: 4.95 V for main unit and 4.9 V
for expanded section
89
7. SERVO INTERFACE B–63833EN/02
7.1.7
Stand–alone Type Separate detector interface unit
Pulse Coder Interface JF101 to JF104 Separate detector
(PCR–EV20MDT)
D For absolute detector 1 PCA 11
Pulse coder
(MS3102A–22–14P)
2 *PCA 12 0V
3 PCB 13 A PCA B *PCA C PCB D *PCB
4 *PCB 14 0V E PCZ F *PCZ G H
5 PCZ 15 J K L +5V M 0V
6 *PCZ 16 0V N SHLD P R S REQ
7 +6V 17 T +6VA U 0VA V
8 REQ 18 +5V
9 +5V 19
10 20 +5V
MS3106B22–14S
Cable wiring
1 A
PCA PCA
2 B
*PCA *PCA
3 C
PCB PCB
4 D
*PCB *PCB
5 E
PCZ PCZ
6 F
*PCZ *PCZ
7 T
+6V +6VA
8 S
REQ REQ
9
+5V
18
+5V
20 L
+5V +5V
12 M
0V 0V
14
0V
16 U
0V 0VA
N
SHLD
SHIELD (Shield)
GROUNDING PLATE
RECOMMENDED CABLE MATERIAL
A66L–0001–0286 (#20AWG 6 + #24AWG 3–pair)
Recommended connectors:
PCR–E20FA (Honda Tsushin Kogyo)
FI30–20S (Hirose Electric)
FCN–247J020–G/E (Fujitsu)
52622–2011 (Molex)
FI40B–2015S (Hirose Electric)
NOTE
The +5V signals above can be used to feed power to linear
scales. The supply current per linear scale is 0.35 A
maximum.
Minimum tolerance to 5 V: 4.95 V for main unit and 4.9 V
for expanded section
90
B–63833EN/02 7. SERVO INTERFACE
(Parallel interface)
Cable wiring
1 A
PCA PCA
2 D
*PCA *PCA
3 B
PCB PCB
4 E
*PCB *PCB
5 F
PCZ PCZ
6 G
*PCZ *PCZ
9 C
+5V +5V
18 J
+5V +5V
20 K
+5V +5V
12 N
0V 0V
14 P
0V 0V
16 T
0V 0V
H
SHLD
(Shield)
SHIELD
GROUNDING PLATE
RECOMMENDED CABLE MATERIAL
A66L–0001–0286 (#20AWG 6 + #24AWG 3–pair)
Recommended connectors:
PCR–E20FA (Honda Tsushin Kogyo)
FI30–20S (Hirose Electric)
FCN–247J020–G/E (Fujitsu)
52622–2011 (Molex)
FI40B–2015S (Hirose Electric)
NOTE
The +5V signals above can be used to feed power to linear
scales. The supply current per linear scale is 0.35 A
maximum.
Minimum tolerance to 5 V: 4.95 V for main unit and 4.9 V
for expanded section
91
7. SERVO INTERFACE B–63833EN/02
1 SD 11 A SD B C D :SD
2 :SD 12 0V E F REQ G REQ H SHLD
3 13 J +5V K +5V L M
4 14 0V N 0V P R +6VA S 0VA
5 REQ 15 T 0V
6 :REQ 16 0V
7 +6V 17
8 18 +5V
MS3106B20–29SW
9 +5V 19
10 20 +5V
Cable connection
1 A
SD SD
2 D
:SD vSD
5 F
REQ REQ
6 G
:REQ :REQ
7 R
+6V +6VA
18 J
+5V +5V
20 K
+5V +5V
12 N
0V 0V
14 T
0V 0V
16 S
0V 0VA
H
SHLD
(Shield) (Shield)
Ground plate
Recommended cable:
A66L–0001–0266 (#20AWG × 6 + #24AWG × 3 pairs)
Recommended connector:
PCR–E20FA (Honda Tsushin Kogyo)
FI30–20S (Hirose Electric)
FCN–247J020–G/E (Fujitsu)
52622–2011 (Molex Japan)
FI40B–2015S (Hirose Electric)
NOTE
1 The +5V signals above can be used to feed power to linear
scales. The supply current per linear scale is 0.35 A
maximum.
Minimum tolerance to 5 V: 4.95 V for main unit and 4.9 V
for expanded section
2 When the 9090 series servo software is used, the serial
interface cannot be used.
92
B–63833EN/02 7. SERVO INTERFACE
7.1.8 The standard of the feedback signal from the additional detector is as
Input Signal shown below.
Requirements (1) A and B phase signal input
This is a method to input position information by the mutual 90 degree
phase slip of A and B phase signals.
Detection of the position is performed with the state in which the B phase
is leading taken as a shift in the plus direction, and the state in which the
A phase is leading as a shift in the minus direction.
A phase signal
Shift in plus direction
B phase signal
A phase signal
Shift in minus direction
B phase signal
Td Td Td Td
Tp
For the Z phase signal (1 rotation signal), a signal width of more than 1/4
frequency of the A phase or B phase signals is necessary.
Z phase signal
Tw
93
7. SERVO INTERFACE B–63833EN/02
Time requirements Requirements for the signals at the input pins of input connectors JF101
to JF104.
TD y 0.15 µsec
The signals for these connectors are differential input signals with A and
B phases. An important factor is time TD from point A, when the
potential difference between PCA and *PCA exceeds 0.5V, to point B,
when the potential difference between PCB and *PCB becomes lower
than 0.5V. The minimum value of TD is 0.15 µs. The period and pulse
width of the signals must be long enough to satisfy the above
requirements.
Receiver circuit
5V
Relationship between If the separate pulse coder rotates in the opposite direction to that of the
the direction of rotation servo motor, reconnect the interface cable of the separate pulse coder as
of the servo motor and described below.
that of the separate (1) Exchange signal PCA with signal PCB.
pulse coder (2) Exchange signal *PCA with signal *PCB.
94
B–63833EN/02 7. SERVO INTERFACE
7.1.9
Connection of Battery
for Separate Absolute
Detector
95
7. SERVO INTERFACE B–63833EN/02
JA4A
(PCR–EV20MDT)
01 11 (M3 terminal)
02 12
+ –
03 0V 13
+6V 0V
04 14
05 15
06 16
07 +6V 17
08 18
09 19
10 20
CABLE CONNECTION
JA4A Battery case
+6V 7 + +6V
0V 3 – 0V
NOTE
The battery for the separate absolute detector is required
only when the separate absolute detector is used. When an
absolute pulse coder with built–in motor is used, it is
powered by the built–in battery of the amplifier, such that the
battery for the separate absolute detector is not required.
96
B–63833EN/02 7. SERVO INTERFACE
97
7. SERVO INTERFACE B–63833EN/02
Vent holes
Basic unit
Basic unit
98
B–63833EN/02 7. SERVO INTERFACE
7.1.12
Notes on Installing a
Separate Detector CAUTION
To install/remove the unit, a screwdriver must be inserted
Interface Unit
obliquely. So, sufficient access clearances are required on
both sides of the unit. As a guideline, if the front of an
adjacent unit appears flush with the unit or slightly set back,
allow a clearance of about 20 mm between the unit and the
adjacent unit. If the front of an adjacent unit protrudes
beyond the front of the unit, allow a clearance of about 70
mm between the unit and the adjacent unit. Also, when
installing the unit near a side of the cabinet, allow a
clearance of about 70 mm between the unit and the side of
the cabinet.
99
7. SERVO INTERFACE B–63833EN/02
DIN rail
Removing
the unit from
the DIN rail
DIN rail
CAUTION
When removing the unit, be careful not to damage the lock
by applying excessive force. When installing and removing
the unit, hold the upper and lower ends of the unit so that
stress is not applied to the side (that surface with the slits)
of the unit.
100
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
101
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
8.1 The Series 0i has a built–in I/O board for machine interface I/O. Number
of DI/DO points for built–in I/O card are 96/64 points. This built–in I/O
GENERAL board must be assigned as the first slave of the I/O Link with the PMC
ladder according to the following tables.
NOTE
1 Since readout from a manual pulse generator (X12 to X14)
is directly performed by the CNC, only the above
assignment must be performed by the PMC.
2 See Subsec. 8.3.3 for details on DO alarm detection (X15).
If the number of DI/DO points is not sufficient, external I/O units such as
the dispersed I/O can be added using the FANUC I/O Link.
MIL ribbon cable connectors are used as the internal connectors for the
built–in I/O board to simplify connection with the connector panel.
The Series 0i Mate has no built–in I/O cards. Use the operator’s panel I/O
module described in Chapter 9 as machine interface I/O.
DO signal reaction to a If a system alarm occurs in a CNC using this 48/32–point I/O module, or
system alarm if I/O Link communication between the CNC and operator’s panel I/O
module fails, all the DO signals of the I/O module are turned off.
Therefore, due care must be taken when setting up the machine sequence.
Also, the same phenomenon occurs if the power of the CNC or the I/O
module is turned off.
102
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
8.2 The following cautions must be observed when using I/O signal receivers
and drivers for the machine interface.
CAUTIONS
8.2.1 DI signals are basically of the sink type (a type that drains energy). Some
DI Signals and DI signals, however, can be set to either sink type or source type (a type
that supplies energy). See the description of the I/O board in the following
Receivers section for details.
A common signal is provided for selectable receivers. Whether the
common signal is connected to 0 V or 24 V determines whether a DI
signal is of sink or source type.
A source type DI signal is undesirable from the viewpoint of safety,
however, because if the input signal line is grounded, it will be latched in
the same state as that existing when the contact is closed. It is
recommended that all DI signals be set to sink type.
Always connect the common signal to either 0 or 24 V; do not leave it
open.
8.2.2 The driver of DO signals is source type (a type that supplies energy,
DO Signals and Drivers non–insulating).
If a system alarm occurs in a control unit of the Series 0i, all I/O board
drivers are turned off. Keep this in mind when setting up a machine
sequence.
The same situation can occur if the power to the control unit is turned off
independently.
103
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
8.3
BUILT–IN I/O CARD
CONNECTION
104
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
8.3.1
Connector Pin
Arrangement
A B A B A B A B
01 0V +24V 01 0V +24V 01 0V +24V 01 0V +24V
02 X0000.0 X0000.1 02 X0003.0 X0003.1 02 X0004.0 X0004.1 02 X0007.0 X0007.1
03 X0000.2 X0000.3 03 X0003.2 X0003.3 03 X0004.2 X0004.3 03 X0007.2 X0007.3
04 X0000.4 X0000.5 04 X0003.4 X0003.5 04 X0004.4 X0004.5 04 X0007.4 X0007.5
05 X0000.6 X0000.7 05 X0003.6 X0003.7 05 X0004.6 X0004.7 05 X0007.6 X0007.7
06 X0001.0 X0001.1 06 X0008.0 X0008.1 06 X0005.0 X0005.1 06 X0010.0 X0010.1
07 X0001.2 X0001.3 07 X0008.2 X0008.3 07 X0005.2 X0005.3 07 X0010.2 X0010.3
08 X0001.4 X0001.5 08 X0008.4 X0008.5 08 X0005.4 X0005.5 08 X0010.4 X0010.5
09 X0001.6 X0001.7 09 X0008.6 X0008.7 09 X0005.6 X0005.7 09 X0010.6 X0010.7
10 X0002.0 X0002.1 10 X0009.0 X0009.1 10 X0006.0 X0006.1 10 X0011.0 X0011.1
11 X0002.2 X0002.3 11 X0009.2 X0009.3 11 X0006.2 X0006.3 11 X0011.2 X0011.3
12 X0002.4 X0002.5 12 X0009.4 X0009.5 12 X0006.4 X0006.5 12 X0011.4 X0011.5
13 X0002.6 X0002.7 13 X0009.6 X0009.7 13 X0006.6 X0006.7 13 X0011.6 X0011.7
14 14 14 COM4 14
15 15 15 15
16 Y0000.0 Y0000.1 16 Y0002.0 Y0002.1 16 Y0004.0 Y0004.1 16 Y0006.0 Y0006.1
17 Y0000.2 Y0000.3 17 Y0002.2 Y0002.3 17 Y0004.2 Y0004.3 17 Y0006.2 Y0006.3
18 Y0000.4 Y0000.5 18 Y0002.4 Y0002.5 18 Y0004.4 Y0004.5 18 Y0006.4 Y0006.5
19 Y0000.6 Y0000.7 19 Y0002.6 Y0002.7 19 Y0004.6 Y0004.7 19 Y0006.6 Y0006.7
20 Y0001.0 Y0001.1 20 Y0003.0 Y0003.1 20 Y0005.0 Y0005.1 20 Y0007.0 Y0007.1
21 Y0001.2 Y0001.3 21 Y0003.2 Y0003.3 21 Y0005.2 Y0005.3 21 Y0007.2 Y0007.3
22 Y0001.4 Y0001.5 22 Y0003.4 Y0003.5 22 Y0005.4 Y0005.5 22 Y0007.4 Y0007.5
23 Y0001.6 Y0001.7 23 Y0003.6 Y0003.7 23 Y0005.6 Y0005.7 23 Y0007.6 Y0007.7
24 DOCOM DOCOM 24 DOCOM DOCOM 24 DOCOM DOCOM 24 DOCOM DOCOM
25 DOCOM DOCOM 25 DOCOM DOCOM 25 DOCOM DOCOM 25 DOCOM DOCOM
NOTE
The B01 +24 V pins of the connectors (CB104, CB105,
CB106, and CB107) are used for the DI input signals, and
which output 24 VDC.
Do not connect +24 V of an external power supply to these
pins.
105
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
8.3.2
Connecting DI/DO
X0000.0 CB104(A02)
RV
X0000.1 CB104(B02)
RV
X0000.2 CB104(A03)
RV
X0000.3 CB104(B03)
RV
X0000.4 CB104(A04)
RV
X0000.5 CB104(B04)
RV
X0000.6 CB104(A05)
RV
X0000.7 CB104(B05)
RV
0V
X0001.0 CB104(A06)
RV
X0001.1 CB104(B06)
RV
X0001.2 CB104(A07)
RV
X0001.3 CB104(B07)
RV
X0001.4 CB104(A08)
RV
X0001.5 CB104(B08)
RV
X0001.6 CB104(A09)
RV
X0001.7 CB104(B09)
RV
0V
106
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
Terminal No.
Address No.
Bit No. +24V
CB104(B01),CB105(B01)
X0002.0 CB104(A10)
RV
X0002.1 CB104(B10)
RV
X0002.2 CB104(A11)
RV
X0002.3 CB104(B11)
RV
X0002.4 CB104(A12)
RV
X0002.5 CB104(B12)
RV
X0002.6 CB104(A13)
RV
X0002.7 CB104(B13)
RV
0V
X0003.0 CB105(A02)
RV
X0003.1 CB105(B02)
RV
X0003.2 CB105(A03)
RV
X0003.3 CB105(B03)
RV
X0003.4 CB105(A04)
RV
X0003.5 CB105(B04)
RV
X0003.6 CB105(A05)
RV
X0003.7 CB105(B05)
RV
0V
107
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
Terminal No.
Address No.
Bit No. +24V
CB106(B01)
X0004.0 CB106(A02)
RV
X0004.1 CB106(B02)
RV
X0004.2 CB106(A03)
RV
X0004.3 CB106(B03)
RV
X0004.4 CB106(A04)
RV
X0004.5 CB106(B04)
RV
X0004.6 CB106(A05)
RV
X0004.7 CB106(B05)
RV
COM4 CB106(A14)
CB106(A01)
0V
X0005.0 CB106(A06)
RV
X0005.1 CB106(B06)
RV
X0005.2 CB106(A07)
RV
X0005.3 CB106(B07)
RV
X0005.4 CB106(A08)
RV
X0005.5 CB106(B08)
RV
X0005.6 CB106(A09)
RV
X0005.7 CB106(B09)
RV
0V
108
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
Terminal No.
Address No.
Bit No. +24V
CB106(B01),CB107(B01)
X0006.0 CB106(A10)
RV
X0006.1 CB106(B10)
RV
X0006.2 CB106(A11)
RV
X0006.3 CB106(B11)
RV
X0006.4 CB106(A12)
RV
X0006.5 CB106(B12)
RV
X0006.6 CB106(A13)
RV
X0006.7 CB106(B13)
RV
0V
X0007.0 CB107(A02)
RV
X0007.1 CB107(B02)
RV
X0007.2 CB107(A03)
RV
X0007.3 CB107(B03)
RV
X0007.4 CB107(A04)
RV
X0007.5 CB107(B04)
RV
X0007.6 CB107(A05)
RV
X0007.7 CB107(B05)
RV
0V
109
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
Terminal No.
Address No.
Bit No. +24V
CB105(B01)
X0008.0 CB105(A06)
RV
X0008.1 CB105(B06)
RV
X0008.2 CB105(A07)
RV
X0008.3 CB105(B07)
RV
X0008.4 CB105(A08)
RV
X0008.5 CB105(B08)
RV
X0008.6 CB105(A09)
RV
X0008.7 CB105(B09)
RV
0V
X0009.0 CB105(A10)
RV
X0009.1 CB105(B10)
RV
X0009.2 CB105(A11)
RV
X0009.3 CB105(B11)
RV
X0009.4 CB105(A12)
RV
X0009.5 CB105(B12)
RV
X0009.6 CB105(A13)
RV
X0009.7 CB105(B13)
RV
0V
110
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
Terminal No.
Address No.
Bit No. +24V
CB107(B01)
X0010.0 CB107(A06)
RV
X0010.1 CB107(B06)
RV
X0010.2 CB107(A07)
RV
X0010.3 CB107(B07)
RV
X0010.4 CB107(A08)
RV
X0010.5 CB107(B08)
RV
X0010.6 CB107(A09)
RV
X0010.7 CB107(B09)
RV
0V
X0011.0 CB107(A10)
RV
X0011.1 CB107(B10)
RV
X0011.2 CB107(A11)
RV
X0011.3 CB107(B11)
RV
X0011.4 CB107(A12)
RV
X0011.5 CB107(B12)
RV
X0011.6 CB107(A13)
RV
X0011.7 CB107(B13)
RV
0V
111
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
+24V 0V
+24V stabilized
power supply
DV
Y0000.0 CB104(A16)
Relay
Y0000.1 CB104(B16)
DV
Y0000.2 CB104(A17)
DV
Y0000.3 CB104(B17)
DV
Y0000.4 CB104(A18)
DV
Y0000.5 CB104(B18)
DV
Y0000.6 CB104(A19)
DV
Y0000.7 CB104(B19)
DV
Y0001.0 CB104(A20)
DV
Y0001.1 CB104(B20)
DV
Y0001.2 CB104(A21)
DV
Y0001.3 CB104(B21)
DV
Y0001.4 CB104(A22)
DV
Y0001.5 CB104(B22)
DV
Y0001.6 CB104(A23)
DV
Y0001.7 CB104(B23)
DV
CB104(A01)
0V
112
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
Terminal No.
Address No.
Bit No. CB104(A24,B24,A25,B25)
CB105(A24,B24,A25,B25)
CB106(A24,B24,A25,B25)
CB107(A24,B24,A25,B25)
+24V 0V
+24V stabilized
power supply
DV
Y0002.0 CB105(A16)
Relay
Y0002.1 CB105(B16)
DV
Y0002.2 CB105(A17)
DV
Y0002.3 CB105(B17)
DV
Y0002.4 CB105(A18)
DV
Y0002.5 CB105(B18)
DV
Y0002.6 CB105(A19)
DV
Y0002.7 CB105(B19)
DV
Y0003.0 CB105(A20)
DV
Y0003.1 CB105(B20)
DV
Y0003.2 CB105(A21)
DV
Y0003.3 CB105(B21)
DV
Y0003.4 CB105(A22)
DV
Y0003.5 CB105(B22)
DV
Y0003.6 CB105(A23)
DV
Y0003.7 CB105(B23)
DV
CB105(A01)
0V
113
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
Terminal No.
Address No.
Bit No. CB104(A24,B24,A25,B25)
CB105(A24,B24,A25,B25)
CB106(A24,B24,A25,B25)
CB107(A24,B24,A25,B25)
+24V 0V
+24V stabilized
power supply
DV
Y0004.0 CB106(A16)
Relay
Y0004.1 CB106(B16)
DV
Y0004.2 CB106(A17)
DV
Y0004.3 CB106(B17)
DV
Y0004.4 CB106(A18)
DV
Y0004.5 CB106(B18)
DV
Y0004.6 CB106(A19)
DV
Y0004.7 CB106(B19)
DV
Y0005.0 CB106(A20)
DV
Y0005.1 CB106(B20)
DV
Y0005.2 CB106(A21)
DV
Y0005.3 CB106(B21)
DV
Y0005.4 CB106(A22)
DV
Y0005.5 CB106(B22)
DV
Y0005.6 CB106(A23)
DV
Y0005.7 CB106(B23)
DV
CB106(A01)
0V
114
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
Terminal No.
Address No.
Bit No. CB104(A24,B24,A25,B25)
CB105(A24,B24,A25,B25)
CB106(A24,B24,A25,B25)
DOCOM CB107(A24,B24,A25,B25)
+24V 0V
+24V stabilized
power supply
DV
Y0006.0 CB107(A16)
Relay
Y0006.1 CB107(B16)
DV
Y0006.2 CB107(A17)
DV
Y0006.3 CB107(B17)
DV
Y0006.4 CB107(A18)
DV
Y0006.5 CB107(B18)
DV
Y0006.6 CB107(A19)
DV
Y0006.7 CB107(B19)
DV
Y0007.0 CB107(A20)
DV
Y0007.1 CB107(B20)
DV
Y0007.2 CB107(A21)
DV
Y0007.3 CB107(B21)
DV
Y0007.4 CB107(A22)
DV
Y0007.5 CB107(B22)
DV
Y0007.6 CB107(A23)
DV
Y0007.7 CB107(B23)
DV
CB107(A01)
0V
115
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
8.3.3
I/O Signal Requirements Contact capacity :
Requirements and for DI signals 30 VDC 16 mA or more
External Power Supply Leakage current between contact points for an open circuit :
1 mA or less (at 26.4 V)
for DO Voltage drop between contact points for a closed circuit :
2 V or less (including the voltage drop in the cables)
CAUTION
Never use the following DO parallel connection.
DOCOM
+24V 0V
DV
Relay
DV
0V
116
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
CAUTION
2 When using a dark lighting resistor as shown in the following
figure, use a leakage–proof diode.
DOCOM
+24V 0V
Dark
lighting
resister
DV Lamp
Leakage–proof diode
0V
117
8. CONNECTING MACHINE INTERFACE I/O B–63833EN/02
NOTE
Output signal driver
Each of the output signal driver devices used on this I/O
board outputs eight signals.
A driver device monitors the current of each output signal.
If it detects an overcurrent on an output, it turns off the
output. Once an overcurrent causes an output to turn off,
the overcurrent is no longer present. Then, the output is
turned on again. In ground–fault or overload conditions,
outputs may turn on and off alternately. This phenomenon
also occurs when a load with a high surge current is
connected.
Each driver device contains an overheat detector circuit. If
an overcurrent is observed on an output continuously
because of a ground–fault or similar reason and the
temperature in the device rises, the overheat detector circuit
turns off all eight outputs. The output–off state is
maintained. This state can be released by logically turning
off then on again the outputs after the internal temperature
of the device drops to a specified level. This state can also
be released by turning off the system power supply.
The output signals of the driver devices are assigned the
following addresses:
Device #0: Y0000.0 to Y0000.7
Device #1: Y0001.0 to Y0001.7
Device #2: Y0002.0 to Y0002.7
Device #3: Y0003.0 to Y0003.7
Device #4: Y0004.0 to Y0004.7
Device #5: Y0005.0 to Y0005.7
Device #6: Y0006.0 to Y0006.7
Device #7: Y0007.0 to Y0007.7
If NC diagnosis shows that an output is on but the output is
actually not turned on, an overload on that output or another
output in the same device may have turned off the eight
outputs of that device. In such a case, turn off the system
power supply and remove the cause of the overload.
118
B–63833EN/02 8. CONNECTING MACHINE INTERFACE I/O
DOCOM
OHD
CONTROL
IN#0 OUT#0
LOGIC
OCD
CONTROL
IN#1 OUT#1
LOGIC
OCD
⋅ ⋅
⋅ ⋅ ⋅ ⋅
⋅ ⋅ ⋅ ⋅
CONTROL
IN#7 OUT#7
LOGIC
OCD
119
9. CONNECTION TO FANUC I/O Link B–63833EN/02
120
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.1 The FANUC I/O Link is a serial interface which connects the CNC, cell
controller, dispersed I/O, machine operator’s panel, or Power Mate and
GENERAL transfers I/O signals (bit data) at high speeds between each device. The
FANUC I/O Link regards one device as the master and other devices as
slaves when more than one device is connected. Input signals from the
slaves are sent to the master at specified intervals. Output signals from
the master are also sent to the slaves at specified intervals.
121
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.2 The interface connector JD1A exists on the I/O card for the Series 0i or
on the main board for the Series 0i Mate.
CONNECTION In the I/O Link there are the master station and its slave stations. As the
Series 0i/0i Mate control unit, the master is connected to slaves such as
a distributed I/O slave. The slaves are divided into groups, and up to 16
groups can be connected to one I/O Link. (For the Series 0i Mate,
however, the number of I/O points is restricted.)
The I/O Link is connected in different ways depending on the types of
units actually used and the I/O points. To connect the I/O Link, the
assignment and addresses of the I/O signals have been made
programmable with the PMC program. The maximum number of I/O
points is 1024.
The two connectors of the I/O Link are named JD1A and JD1B, and are
common to all units (that have I/O Link function). A cable is always
connected from JD1A of a unit to JD1B of the next unit. Although JD1A
of the last unit is not used and left open, it need not be connected with a
terminator.
The pin assignments of connectors JD1A and JD1B are common to all
units on the I/O Link, and are illustrated on Subsec. 9.2.1. Use the figures
when connecting the I/O Link irrespective of the type of unit.
Control unit
Slave unit
JD1B
Magnetic
JD1A
circuit
Max.
JD1B
16 group
JD1A
…
…
JD1B
JD1A
122
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Series 0i Mate
control unit
123
9. CONNECTION TO FANUC I/O Link B–63833EN/02
NOTE
1 Since readout from the manual pulse generator (X12 to
X14) is directly performed by the CNC, only the above
assignment must be performed by the PMC.
2 See Subsec. 9.5.8 for details on DO alarm detection (X15
and X31).
3 For the Series 0i Mate, only the above units can be added.
124
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Series 0i
control unit
125
9. CONNECTION TO FANUC I/O Link B–63833EN/02
NOTE
1 Since readout from the manual pulse generator (X12 to
X14) is directly performed by the CNC, only the above
assignment must be performed by the PMC.
2 See Subsec. 9.5.8 for details on DO alarm detection (X15).
126
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.2.1
Connection of FANUC
I/O Link by Electric
Cable
Control unit or preceding slave unit
JD1A JD1B
(PCR–EV20MDT) (PCR–E20LMD) JD1A
(PCR–E20LMD)
1 SIN 11 0V JD1B 1 SIN 11 0V
2 :SIN 12 0V 2 :SIN 12 0V
3 SOUT 13 0V 3 SOUT 13 0V
Next slave
4 :SOUT 14 0V 4 :SOUT 14 0V unit
5 15 5 15
6 16 6 16
7 17 7 17
8 18 (+5V) 8 18 (+5V)
9 (+5V) 19 9 (+5V) 19
10 20 (+5V) 10 20 (+5V)
+5 V terminals are for an optical I/O Link adapter. They are not necessary
when connecting with a metal cable.
A line for the +5V terminal is not required when the Optical I/O Link
Adapter is not used.
Cable wirinr
SIN 1 3 SOUT
:SIN 2 4 :SOUT
SOUT 3 1 SIN
:SOUT 4 2 :SIN
0V 11 11 0V
0V 12 12 0V
0V 13 13 0V
0V 14 14 0V
Shield
Ground Plate
Recommended Cable Material
A66L–0001–0284#10P(#28AWG 10pair)
9.2.2 Take the following precautions about the power supply of a slave unit
Power Supply connected through the FANUC I/O Link.
Precautions D During power–up, supply +24 V when or before turning on the CNC.
D During power–down, stop supplying +24 V when or after turning off
the CNC.
D When turning off a slave unit, be sure to turn off the other units
connected through the same I/O Link.
These are general rules. Therefore, when additional rules are specified for
each unit, be sure to observe them.
127
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.3 Basically, the Series 0i can be connected to any unit that has a FANUC
I/O Link slave interface. For the Series 0i Mate, however, only the
UNITS THAT CAN BE following units can be connected. Detailed descriptions of each unit are
CONNECTED USING given later in this section. For details on the other units used with the
FANUC I/O Link Series 0i, see the manual for each unit.
128
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4
CONNECTION TO
MACHINE
OPERATOR’S PANEL
9.4.1 This machine operator’s panel is connected with CNC by I/O Link, which
Overview is composed with the following 2 operator’s panels.
129
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.2
Total Connection
Diagram
JD1A
CM66
130
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.3
Connections
9.4.3.1
Pin assignment
CA64 (Power source) CA65 (Power magnetic cabinet)
3 2 0V 1 +24V A01 EON B01 EOFF
6 5 0V 4 +24V A02 COM1 B02 COM2
NOTE
1 Input/output Pins shaded by are in pairs. Only one in each pair is usable.
2 Pins shaded by are those for forwarding signals. Pins with the same name are connected
directly to one another.
131
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.3.2 To the connector CA64 (IN), shown in the figure below, supply the power
Power supply necessary for this operator’s panel to operate and the power necessary for
general–purpose DI. To facilitate power branching, the powers supplied
connection
to CA64 (IN) are output directly to CA64 (OUT). If power branching is
required, use CA64 (OUT).
CA64 (IN)
01 +24V
24VDC power 02 0V
03
CA64 (OUT)
01 +24V
24VDC power 02 0V
03
NOTE
1 Both connectors CA64 (IN) and CA64 (OUT) are same
specification. And there is not indication of (IN) and (OUT)
on the PCB.
2 Power supply for the operator’s panel must not turn off at
operation. If +24V is turned off at operation, CNC happen
to get system alarm (Communication alarm between CNC
and operator’s panel). +24V for operator’s panel must be
supplied before or same time CNC power on.
132
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.3.3
I/O link connection
JD1A JD1B
(PCR–E20MDK–SL–A) (PCR–E20MDK–SL–A)
JD1A
1 SIN 11 0V JD1B 1 SIN 11 0V
2 :SIN 12 0V 2 :SIN 12 0V
3 SOUT 13 0V 3 SOUT 13 0V
Next slave
4 :SOUT 14 0V 4 :SOUT 14 0V unit
5 15 5 15
6 16 6 16
7 17 7 17
8 18 (+5V) 8 18 (+5V)
9 (+5V) 19 9 (+5V) 19
10 20 (+5V) 10 20 (+5V)
+5V terminals are for an optical I/O Link adapter. They are not necessary
when connecting with a metal cable.
If not using the optical I/O link adapter, do not connect the +5 V pin.
JD1A JD1B
SIN 1 3 SOUT
:SIN 2 4 :SOUT
SOUT 3 1 SIN
:SOUT 4 2 :SIN
0V 11 11 0V
0V 12 12 0V
0V 13 13 0V
0V 14 14 0V
Shield
Ground Plate
Recommended wire material:
A66L–0001–0284#10P (AWG28 10 pairs)
133
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.3.5 Signal generated by the power ON/OFF control switches on the machine
Power ON/OFF control operator’s panel can be sent to the power magnetic cabinet. (This signal
cannot be sent to the FANUC I/O Link.)
signal connection
Sub panel B1 is not included Emergency stop button.
Main panel B
ON switch P.C.B.
CM67 CA65
EON
A01 A01 EON
COM1
A02 A02 COM
OFF switch
EOFF
B01 B01 EOFF
COM2
B02 B02
134
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.3.6
DI (input signal)
connection
Pin number
+24V
CM68(A1),CM69(A1),
Address number JA58(10),JA58(19)
Bit
Sub panel B1
CM65(A04) D Rotary switch
CM65(B05) A (SA1)
Xm+0.0
RV
Xm+0.1 CM65(A03) F
RV
Xm+0.2 CM65(A05) B
RV
Xm+0.3 CM65(B03) E
RV
Xm+0.4 CM65(B04) C
RV
Xm+0.5 CM65(B02) G
RV
CM66(A04) D Rotary switch
CM66(B05) A (SA2)
Xm+0.6
RV
Xm+0.7 CM66(A03) F
RV
Xm+1.0 CM66(A05) B
RV
Xm+1.1 CM66(B03) E
RV
Xm+1.2 CM66(B04) C
RV
Xm+1.3 CM66(B02) G
RV
CM67(B03)
CM67(A03) Memory protect
Xm+1.4
RV
(SA3)
JA58(11)
Xm+1.5 CM68(B01)
RV
JA58(13)
Xm+1.6 CM68(A02)
RV
JA58(15)
Xm+1.7 CM68(B02)
RV
+24V
0V
135
9. CONNECTION TO FANUC I/O Link B–63833EN/02
0V
Xm+3.0 CM69(B02)
RV
Xm+3.1 CM69(A03)
RV
Xm+3.2 CM69(B03)
RV
Xm+3.3 CM69(A04)
RV
Xm+3.4 CM69(B04)
RV
Xm+3.5 CM69(A05)
RV
Xm+3.6 CM69(B05)
RV
Xm+3.7 CM69(A06)
RV
DICOM CM69(B06) 0V
NOTE
1 Xm+3.0 to 3.7 have a common line that is possible to select the source/sink type. If DICOM
(CM69–B06pin) is connected to +24V, the DI signal logic is negative. But in this connection,
if the DI signal wires happen to drop the ground level, the status of the DI signal is same as the
DI signal is “ON”. From the safety viewpoint, DICOM should be connected 0V.
2 Xm+0.0 to 0.7, Xm+1.0 to 1.7 and Xm+2.0 to 0.7 common lines are fixed. So, if these DI pins
in this address open, the status of these one stay “0”. And in case of Xm+3.0 to 3.7 which have
a selectable common line, if the DICOM(CM69–B06pin) is connected to 0V and these DI pins
open, the status of these one stay “0”. And if the DICOM are connected to +24V and these DI
pins open, the status of these one stay “1”. And if the DICOM is not connected to 0V or +24V
and these DI pins open, the status of these one don’t care.
136
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.3.7
DO (output signal)
connection
Pin number
DOCOM
CM68(A10),CM69(A10)
Address No.
Bit +24V 0V
+24V Power
JA58(7)
Yn+5.3 CM68(A08)
Relay
DV
Yn+5.7
DV CM68(B08)
Yn+6.3
DV CM68(A09)
Yn+6.7
DV CM68(B09)
Yn+7.3
DV CM69(A08)
Yn+7.4
DV CM69(B08)
Yn+7.5
DV CM69(A09)
Yn+7.6
DV CM69(B09)
CM68(B10),CM69(B10)
0V
137
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.3.8
Connector (on the cable
side) specifications
Hirose
FI40B–20S (Connector)
FI–20–CV2 (Case)
Hirose
FI30–20S (Connector)
FI–20–CV2 (Case)
138
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.4
DI/DO Address
9.4.4.1 DI/DO address of Keyswitches and LED on the keyboard of Main panel
Keyboard of main panel B are as follows.
BIT
7 6 5 4 3 2 1 0
Key/LED
Xm+4/Yn+0 B4 B3 B2 B1 A4 A3 A2 A1
Xm+5/Yn+1 D4 D3 D2 D1 D4 C3 C2 C1
Xm+6/Yn+2 A8 A7 A6 A5 E4 E3 E2 E1
Xm+7/Yn+3 C8 C7 C6 C5 B8 B7 B6 B5
Xm+8/Yn+4 E8 E7 E6 E5 D8 D7 D6 D5
Keyswitches/LED position
Address 1 2 3 4 5 6 7 8 9 10 11
139
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.4.2 Table of gray code output is as follows when the Sub panel B1 is used
Override signals
Rotary switch (SA1)
% 0 1 2 4 6 8 10 15 20 30 40 50 60 70 80 90 95 100 105 110 120
Xm+0.0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
Xm+0.1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1
Xm+0.2 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1
Xm+0.3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1
Xm+0.4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1
Xm+0.5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
NOTE
Xm+0.5 is a parity bit.
Xm+0.6 0 1 1 0 0 1 1 0
Xm+0.7 0 0 1 1 1 1 0 0
Xm+1.0 0 0 0 0 1 1 1 1
Xm+1.1 0 0 0 0 0 0 0 0
Xm+1.2 0 1 0 1 0 1 0 1
Xm+1.3 0 0 0 0 0 0 0 0
NOTE
Xm+1.2 is a parity bit.
140
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
DI map DO map
Xm+0 Yn+0
Xm+1 General– Yn+1
purpose
Xm+2 DI/DO Yn+2 Keyboard
Xm+3 Yn+3 (LED)
Include
Xm+4 Yn+4 general–
Xm+5 Yn+5 Purpose DO
Xm+6 Yn+6
Keyboard of
Xm+7 Main panel Yn+7
Xm+8 (keyswitches)
Xm+9
Xm+10
Xm+11
9.4.6
Connector Locations
of Main Panel B
Fuse(1A) Unit=mm
141
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.7
Specifications
9.4.7.1
Environmental
requirement
Atmosphere Normal FA atmosphere(Consult us when using the system under environments with higher
degree of dust, coolant, or organic solution.)
9.4.7.2
Order specification
Set of blank key tops A02B–0236–K171 55 key tops with no symbols printed
Set of symbolic key tops A02B–0236–K172 34 symbol key tops + 21 blank key tops
142
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.7.3
Main panel B
specification
MPG interface Max. 3 units This interface cannot be used with the
Series 0i.
Interface to CNC FANUC I/O Link connection Max. 16 modules or total points max.
1024/1024 will be available.
9.4.7.4
Sub panel A, B1
specification
Override rotary switch 2 2 5 bit Gray code output (with a parity bit)
9.4.7.5
Power supply
specification
143
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.7.6
General–purpose DI
signal definition
Interconnect voltage drop in closed circuit 2V or less (including the voltage drop in the cables)
9.4.7.7
General–purpose DO
signal definition
144
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.8
Key Symbol Indication
on Machine Operator’s
Panel
9.4.8.1
Meaning of key symbols
145
9. CONNECTION TO FANUC I/O Link B–63833EN/02
146
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.4.8.2 Keyboard of machine operator’s panel has 55 keys. All key tops are
Detachable key top detachable. MTB can customize keys and make his original key layout
easily. And using transparent key top (optional), a film sheet with marking
is inserted into the key.
Film sheet*
(12.5mm 12.5mm, t=0.1mm Max.)
NOTE
* Use the oil–proof sheet in the environment which oil is used
for.
147
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.4.9 The keyboard of this operator’s panel is a matrix composition. When three
Others or more keys are pushed, the bypass current cause unrelated key to be
available. This malfunction can be prevented with ladder program. One
example is shown as follows.
(Elimination rule of malfunction)
When three keyinputs or more is input, all the keyinput since the third is
made invalid.
However, when the number of all keyinput becomes two or less because
keyinput was lost, all keyinputs are made effective.
Dataline(bit7)
Dataline(bit6)
Dataline(bit5)
Dataline(bit4)
Dataline(bit3)
Dataline(bit2)
Dataline(bit1)
Dataline(bit0)
Dataline(bit7)
Dataline(bit6)
Dataline(bit5)
Dataline(bit4)
Dataline(bit3)
Dataline(bit2)
Dataline(bit1)
Dataline(bit0)
State (d) State (e) State (f)
Com.line1(Xm+4) Com.line1(Xm+4) Com.line1(Xm+4)
Com.line2(Xm+5) Com.line2(Xm+5) Com.line2(Xm+5)
Com.line3(Xm+6) Com.line3(Xm+6) Com.line3(Xm+6)
Com.line4(Xm+7) Com.line4(Xm+7) Com.line4(Xm+7)
Com.line5(Xm+8) Com.line5(Xm+8) Com.line5(Xm+8)
Com.line6(Xm+9) Com.line6(Xm+9) Com.line6(Xm+9)
Com.line7(Xm+10) Com.line7(Xm+10) Com.line7(Xm+10)
Com.line8(Xm+11) Com.line8(Xm+11) Com.line8(Xm+11)
Dataline(bit7)
Dataline(bit6)
Dataline(bit5)
Dataline(bit4)
Dataline(bit3)
Dataline(bit2)
Dataline(bit1)
Dataline(bit0)
Dataline(bit7)
Dataline(bit6)
Dataline(bit5)
Dataline(bit4)
Dataline(bit3)
Dataline(bit2)
Dataline(bit1)
Dataline(bit0)
Dataline(bit7)
Dataline(bit6)
Dataline(bit5)
Dataline(bit4)
Dataline(bit3)
Dataline(bit2)
Dataline(bit1)
Dataline(bit0)
148
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
[2] Judgment 1
(1) If there is no dataline where the keyinput exists.
³ Any key switch is not pushed.: Ex. State (a)
(2) When the keyinput exists in two datalines or less.
³ To [3]
(3) When the keyinput exists in three data lines or more.
³ There are three keyinputs or more.
It is invalid keyinput.: Ex. State (f)
149
9. CONNECTION TO FANUC I/O Link B–63833EN/02
150
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.5
CONNECTION TO
THE OPERATOR’S
PANEL I/O MODULE
9.5.1
Overall Connection
Diagram
CNC
I/O UNIT
JD1B
I/O Link
JD1A
JD1B
JD1A
CE56
MPG
(with Series 0i Mate)
CE57
Power
+24V CPD1(IN)
supply
Power
+24V CPD1(OUT)
supply
Specification Manufacturer
151
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.5.2 Provide the CPD1 (IN) connector, shown below, with the power
Power Connection necessary for the printed circuit board operation and that for DI operation.
To facilitate power division, the power is output to CPD1 (OUT) exactly
as it is input from CPD1 (IN). When power division is required, use
CPD1 (OUT).
CPD1(IN)
01 +24V
24 V power
supply 02 0V
03
CPD1(OUT)
01 +24V
24 V power
supply 02 0V
03
NOTE
The specification of the power supply connector CPD1 (IN)
is the same as that for CPD1 (OUT). There are no
indications on the printed circuit board to distinguish
between the IN and OUT connectors. Do not turn off the +24
V supply to the connector during operation. Turning off the
+24 V supply will cause a CNC communication alarm.
When turning on the power, the +24 V supply to the I/O
module must be turned on before or at the same time as the
power supply to the CNC. When turning off the power, the
+24 V supply to the I/O module must be turned off after or
at the same time as the power supply to the CNC.
152
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.5.3
DI/DO Connector Pin
CE56 CE57
Arrangement
A B A B
01 0V +24V 01 0V +24V
02 Xm+0.0 Xm+0.1 02 Xm+3.0 Xm+3.1
03 Xm+0.2 Xm+0.3 03 Xm+3.2 Xm+3.3
04 Xm+0.4 Xm+0.5 04 Xm+3.4 Xm+3.5
05 Xm+0.6 Xm+0.7 05 Xm+3.6 Xm+3.7
06 Xm+1.0 Xm+1.1 06 Xm+4.0 Xm+4.1
07 Xm+1.2 Xm+1.3 07 Xm+4.2 Xm+4.3
08 Xm+1.4 Xm+1.5 08 Xm+4.4 Xm+4.5
09 Xm+1.6 Xm+1.7 09 Xm+4.6 Xm+4.7
10 Xm+2.0 Xm+2.1 10 Xm+5.0 Xm+5.1
11 Xm+2.2 Xm+2.3 11 Xm+5.2 Xm+5.3
12 Xm+2.4 Xm+2.5 12 Xm+5.4 Xm+5.5
13 Xm+2.6 Xm+2.7 13 Xm+5.6 Xm+5.7
14 DICOM0 14 DICOM5
15 15
16 Yn+0.0 Yn+0.1 16 Yn+2.0 Yn+2.1
17 Yn+0.2 Yn+0.3 17 Yn+2.2 Yn+2.3
18 Yn+0.4 Yn+0.5 18 Yn+2.4 Yn+2.5
19 Yn+0.6 Yn+0.7 19 Yn+2.6 Yn+2.7
20 Yn+1.0 Yn+1.1 20 Yn+3.0 Yn+3.1
21 Yn+1.2 Yn+1.3 21 Yn+3.2 Yn+3.3
22 Yn+1.4 Yn+1.5 22 Yn+3.4 Yn+3.5
23 Yn+1.6 Yn+1.7 23 Yn+3.6 Yn+3.7
24 DOCOM DOCOM 24 DOCOM DOCOM
25 DOCOM DOCOM 25 DOCOM DOCOM
NOTE
The B01 +24 V pins of the connectors (CD56 and CD57) are
used for the DI input signal, and which output 24 VDC.
Do not connect +24 V of an external power supply to these
pins.
153
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.5.4
DI (General–purpose
Input Signal)
Connection
Pin number
Address number CE56(B01)
Bit number +24V
CE57(B01)
Xm+0.0 CE56(A02)
RV
Xm+0.1 CE56(B02)
RV
Xm+0.2 CE56(A03)
RV
Xm+0.3 CE56(B03)
RV
Xm+0.4 CE56(A04)
RV
Xm+0.5 CE56(B04)
RV
Xm+0.6 CE56(A05)
RV
Xm+0.7 CE56(B05)
RV
DICOM0 CE56(A14)
CE56(A01)
0V
CE57(A01)
Xm+1.0 CE56(A06)
RV
Xm+1.1 CE56(B06)
RV
Xm+1.2 CE56(A07)
RV
Xm+1.3 CE56(B07)
RV
Xm+1.4 CE56(A08)
RV
Xm+1.5 CE56(B08)
RV
Xm+1.6 CE56(A09)
RV
Xm+1.7 CE56(B09)
RV
0V
154
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Pin number
Address number CE56(B01)
Bit number +24V
CE57(B01)
Xm+2.0 CE56(A10)
RV
Xm+2.1 CE56(B10)
RV
Xm+2.2 CE56(A11)
RV
Xm+2.3 CE56(B11)
RV
Xm+2.4 CE56(A12)
RV
Xm+2.5 CE56(B12)
RV
Xm+2.6 CE56(A13)
RV
Xm+2.7 CE56(B13)
RV
0V
Xm+3.0 CE57(A02)
RV
Xm+3.1 CE57(B02)
RV
Xm+3.2 CE57(A03)
RV
Xm+3.3 CE57(B03)
RV
Xm+3.4 CE57(A04)
RV
Xm+3.5 CE57(B04)
RV
Xm+3.6 CE57(A05)
RV
Xm+3.7 CE57(B05)
RV
0V
155
9. CONNECTION TO FANUC I/O Link B–63833EN/02
Pin number
Address number CE56(B01)
Bit number +24V
CE57(B01)
Xm+4.0 CE57(A06)
RV
Xm+4.1 CE57(B06)
RV
Xm+4.2 CE57(A07)
RV
Xm+4.3 CE57(B07)
RV
Xm+4.4 CE57(A08)
RV
Xm+4.5 CE57(B08)
RV
Xm+4.6 CE57(A09)
RV
Xm+4.7 CE57(B09)
RV
0V
Xm+5.0 CE57(A10)
RV
Xm+5.1 CE57(B10)
RV
Xm+5.2 CE57(A11)
RV
Xm+5.3 CE57(B11)
RV
Xm+5.4 CE57(A12)
RV
Xm+5.5 CE57(B12)
RV
Xm+5.6 CE57(A13)
RV
Xm+5.7 CE57(B13)
RV
DICOM5 CE57(B14)
CE56(A01)
0V CE57(A01)
156
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
NOTE
Xm+0.0 through Xm+0.7 and Xm+5.0 through Xm+5.7 are
DI pins for which a common voltage can be selected. That
is, by connecting the DICOM0 CE56(A14) or DICOM5
CE57(B14) pin to the +24 V power supply, a DI signal can
be input with its logical state reversed. If, however, a cable
is connected to ground, it has the same effect as inputting
an ON state DI signal. To prevent this from occurring, the
connection of the DICOM0 CE56(A14) and DICOM5
CE57(B14) pins to the 0 V power supply is recommended
whereever possible.
For safety reasons, the emergency stop signal needs to be
allocated to an appropriate bit of the addresses for which
the common voltage is fixed. See “Address allocation” in
Section 9.6.8 for details of how to allocate the emergency
stop signal.
For unused DI pins allocated to the addresses for which the
common voltage is fixed, the logic is fixed to “0”. For unused
pins allocated to the addresses for which the common
voltage can be selected, the logic is fixed to “0” when the
DICOM0 CE56(A14) or DICOM5 CE57(B14) pin is
connected to the 0 V power supply. When the DICOM0
CE56(A14) or DICOM5 CE57(B14) pin is connected to the
+24 V power supply, the logic is fixed to “1”. The logic of the
unused pins is variable when the contacts of the DICOM0
CE56(A14) and DICOM5 CE57(B14) pins are open.
157
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.5.5
DO (Output Signal)
Connection
Pin number
CE56(A24,B24,A25,B25)
DOCOM
CE57(A24,B24,A25,B25)
Address number
Bit number +24V 0V
+24 V stabilized
power supply
Yn+0.0 CE56(A16)
Relay
DV
Yn+0.1 CE56(B16)
DV
Yn+0.2 CE56(A17)
DV
Yn+0.3 CE56(B17)
DV
Yn+0.4 CE56(A18)
DV
Yn+0.5 CE56(B18)
DV
Yn+0.6 CE56(A19)
DV
Yn+0.7 CE56(B19)
DV
Yn+1.0 CE56(A20)
DV
Yn+1.1 CE56(B20)
DV
Yn+1.2 CE56(A21)
DV
Yn+1.3 CE56(B21)
DV
Yn+1.4 CE56(A22)
DV
Yn+1.5 CE56(B22)
DV
Yn+1.6 CE56(A23)
DV
Yn+1.7 CE56(B23)
DV
CE56(A01)
0V CE57(A01)
158
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Pin number
CE56(A24,B24,A25,B25)
DOCOM
CE57(A24,B24,A25,B25)
Address number
Bit number +24V 0V
+24 V stabilized
power supply
Yn+2.0 CE57(A16)
Relay
DV
Yn+2.1 CE57(B16)
DV
Yn+2.2 CE57(A17)
DV
Yn+2.3 CE57(B17)
DV
Yn+2.4 CE57(A18)
DV
Yn+2.5 CE57(B18)
DV
Yn+2.6 CE57(A19)
DV
Yn+2.7 CE57(B19)
DV
Yn+3.0 CE57(A20)
DV
Yn+3.1 CE57(B20)
DV
Yn+3.2 CE57(A21)
DV
Yn+3.3 CE57(B21)
DV
Yn+3.4 CE57(A22)
DV
Yn+3.5 CE57(B22)
DV
Yn+3.6 CE57(A23)
DV
Yn+3.7 CE57(B23)
DV
CE56(A01)
0V
CE57(A01)
159
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.5.6
External View
Note) Lead wires and other components are mounted on the rear
Note face of the printed circuit board. Ensure that the printed circuit
boards are spaced 5 mm or more from one another to prevent
interference.
: Polarity guide
: A1 pin mark
160
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Other requirements (1) Install the I/O module in a fully enclosed cabinet.
Ordering specifications
Item Specification Remarks
Module specifications
Item Specification Remarks
161
9. CONNECTION TO FANUC I/O Link B–63833EN/02
NOTE
Ensure that the maximum current per DOCOM pin (DO
power supply pin) does not exceed 0.7 A.
162
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.5.8
Other Notes
DO signal reaction to a If a system alarm occurs in a CNC using this 48/32–point I/O module, or
system alarm if I/O Link communication between the CNC and operator’s panel I/O
module fails, all the DO signals of the I/O module are turned off.
Therefore, due care must be taken when setting up the machine sequence.
Also, the same phenomenon occurs if the power of the CNC or the I/O
module is turned off.
Address allocation For the operator’s panel I/O module, I/O addresses are mapped as follows.
NOTE
Reserved addresses can not used.
163
9. CONNECTION TO FANUC I/O Link B–63833EN/02
NOTE
Reserved addresses can not used.
Turning the DO (output All the DO signals can be turned off simultaneously by turning off
signal) power on and off (opening) the DO (output signal) power supply pin “DOCOM”. Doing
(DOCOM) so causes the DO signal status to change as shown below.
ON
DOCOM OFF
When DO is ON in ON
the sequence OFF
When DO is OFF
ON
in the sequence
OFF
NOTE
When the DO signal is in the ON state in the sequence, the
ON or OFF state of the DOCOM pin determines the state of
the signal, as shown within dotted lines in the above figure.
Do not turn off the +24 V supply provided by the CPD1 to the
I/O module during the operation. Turning off the +24 V
supply causes a CNC communication alarm. When turning
on the power, the +24 V supply to the I/O module must be
turned on before or at the same time as the power supply
to the CNC. When turning off the power, the +24 V supply
to the I/O module must be turned off after or at the same time
as the power supply to the CNC.
164
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
Parallel DO (output The DO load current can be doubled by connecting two DO points in
signal) connection parallel and turning them on and off simultaneously in sequence, as
shown in the figure below. The maximum load current per DI point is 200
mA. Connecting two DO points in parallel and turning them on at the
same time produces a current of 400 mA. Note that, however, when two
DO points are connected in parallel, the leakage current also doubles
when they are off (max. 40 mA).
+24V 0V
+24 stabilized
power supply
Relay
DV
DV
0V
DO (output signal) alarm The DO driver of the I/O module is capable of detecting an overcurrent
detection and measuring its own temperature. If an accident, such as the connecting
of the cable to ground, causes an abnormal increase in the load current or
in the driver temperature, a protection circuit, which is provided for each
DO driver (1 byte), is activated and keeps the DO signal for the relevant
1 byte in the OFF state until the cause of the problem is eliminated. Even
if this occurs, the CNC and I/O module continue operating. The DI
address (Xm+15) identifies the DO driver which has detected the alarm.
The following table shows the correspondence between the DI address
(Xm+15) bits and the DO addresses. Bit value “1” indicates that the
corresponding DO driver has detected an alarm. The contents of the
Xm+15 area can be checked by using the DGN screen of the CNC or by
performing alarm processing for the area in advance by using Ladder.
This helps alarm detection and recovery.
165
9. CONNECTION TO FANUC I/O Link B–63833EN/02
Xm+15.0 Yn+0
Xm+15.1 Yn+1
Xm+15.2 Yn+2
Xm+15.3 Yn+3
Ground plate
Cable Wire
166
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
(These cables do not include the wire shown in the above figure.)
9.5.10 Like a pulse coder, the manual pulse generator operates on 5 VDC. The
Cable Length for supply voltage drop due to the cable resistance must be held below 0.2 V
(when those of the 0–volt and 5–volt wires are combined), as expressed
Manual Pulse in the following expression:
Generator
0.2 u
+
0.1 R
m
2L
Where
0.1 = manual pulse generator supply current (0.1 A)
R = resistance per unit cable length (W/m)
m = number of 0–volt and 5–volt wires
L = cable length (m).
Lt
+R
m
In the case of the A66L–0001–0286 cable, for example, when three pairs
of signal wires and six power supply wires (20/0.18, 0.0394 W/m) are
used (three power supply wires connected to 5 V and the other three to 0
V), the cable length is:
Lt
+
3 + 76.75[m]
0.0394
However, the maximum pulse transmission distance for the manual pulse
generator is 50 m. Taking this into consideration, the cable length may
be extended to:
38.37 m (when two generators are used), or
25.58 m (when three generators are used).
167
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.6
CONNECTING THE
FANUC SERVO UNIT β
SERIES WITH I/O Link
9.6.1 The FANUC servo unit β series with I/O Link (called the β amplifier with
Overview I/O Link) is a power motion control servo unit that can be easily connected
to a CNC control unit via the FANUC I/O Link.
The β amplifier with I/O Link can be connected to the Series 0i using the
FANUC I/O Link.
However, this cannot be used with the Series 0i Mate.
168
B–63833EN/02 9. CONNECTION TO FANUC I/O Link
9.6.2 The β amplifier with I/O Link is connected to the Series 0i using the usual
Connection FANUC I/O Link connection.
Control unit
JD1B
I/O JD1A
LINK I/O
IOLINK LINK
I/O Link cable
JD1A
I/O Link
cable
JD1B
I/O
LINK
169
9. CONNECTION TO FANUC I/O Link B–63833EN/02
9.6.3 The maximum number of β amplifiers with I/O Link that can be
Maximum Number of connected to a control unit depends on the maximum number of FANUC
I/O Link points provided by that control unit, as well as their assignments.
Units that can be For the Series 0i, the maximum number of FANUC I/O Link DI and DO
Connected points are 1024 and 1024, respectively. One β amplifier with I/O Link
occupies 128 DI/DO points in the FANUC I/O Link. If no units other than
the β amplifiers with I/O Link are connected to the control unit, up to eight
β amplifiers can be connected.
9.6.4 If the β amplifier with I/O Link is used as an I/O Link slave, I/O addresses
Address Assignment are assigned in the PMC in the CNC. Because data output from the slave
is made in 16–byte units, the number of input/output points must be set
by Ladder to 128.
170
B–63833EN/02 10. EMERGENCY STOP SIGNAL
Using the emergency stop signal effectively enables the design of safe
WARNING machine tools. See ”Cautions for configuring emergency stop circuit in
compliance with safety standards.”
The emergency stop signal is provided to bring a machine tool to an
emergency stop. It is input to the CNC controller, servo amplifier, and
spindle amplifier. An emergency stop signal is usually generated by
closing the B contact of a pushbutton switch.
When the emergency stop signal (*ESP) contact is closed, the CNC
controller enters the emergency stop released state, such that the servo and
spindle motors can be controlled and operated.
When the emergency stop signal (*ESP) contact opens, the CNC
controller is reset and enters the emergency stop state, and the servo and
spindle motors are decelerated to a stop.
Shutting off the servo amplifier power causes a dynamic brake to be
applied to the servo motor. Even when a dynamic brake is applied,
however, a servo motor attached to a vertical axis can move under the
force of gravity. To overcome this problem, use a servo motor with a
brake.
While the spindle motor is running, shutting off the motor–driving power
to the spindle amplifier allows the spindle motor to continue running
under its own inertia, which is quite dangerous. When the emergency stop
signal (*ESP) contact opens, it is necessary to confirm that the spindle
motor has been decelerated to a stop, before the spindle motor power is
shut off.
The FANUC servo amplifier αi series products are designed to satisfy the
above requirements. The emergency stop signal should be input to the
power supply module (called the PSM). The PSM outputs a motor power
MCC control signal, which can be used to switch the power applied to the
power supply module on and off.
The CNC controller is designed to detect overtravel by using a software
limit function. Normally, no hardware limit switch is required to detect
overtravel. If the machine goes beyond a software limit because of a servo
feedback failure, however, it is necessary to provide a stroke end limit
switch, connected so that the emergency stop signal can be used to stop
the machine.
Fig. 10 shows an example showing how to use the emergency stop signal
with this CNC controller and αi series servo amplifier.
171
10. EMERGENCY STOP SIGNAL B–63833EN/02
Spark killer
SK
EMG
Relay
CNC control unit
emg1
+24
*ESP
Spark killer
SK
3φ
Coil
200VAC
L1
L2
L3
Fig. 10
WARNING
To use a spindle motor and amplifier produced by a manufacturer other than FANUC, refer to
the corresponding documentation as well as this manual. Design the emergency stop
sequence such that, if the emergency stop signal contact opens while the spindle motor is
rotating, the spindle motor is decelerated until it stops.
172
B–63833EN/02 10. EMERGENCY STOP SIGNAL
Cautions for config- To configure an emergency stop circuit in compliance with JIS safety
standards(*), observe the following cautions. Compliance with these JIS
uring an emergency safety standards is a prerequisite for complying with the EC Machine
stop circuit in com- Instructions.
pliance with safety
standards The method for shutting off the motor power section in the amplifier is
based on an IGBT (transistor) rather than an electromechanical scheme.
When configuring an emergency stop circuit, therefore, install a line
contactor on the power input line for motor power in the power supply
module in order to ensure electromechanical shut–off, and apply voltage
to the control coil of the contactor via the contactor control output of the
power supply module.
A failure in the amplifier may disable the output relay of the power supply
module from going off, thus preventing the line contactor from shutting
off the power, even when the emergency stop command input (*ESP) of
the amplifier becomes low.
If a spindle amplifier module is used, shutting off the motor power line
during spindle rotation disables the spindle from stopping quickly
because the power regenerative function does not work, allowing the
spindle to coast. So, provide the redundancy circuit mentioned above
with a delay function based on an off–delay timer that allows a usual stop
time.
NOTE
Examples of important safety standards. Enclosed in
parentheses are corresponding European standards.
173
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
174
B–63833EN/02 11. HIGH–SPEED SERIAL BUS (HSSB)
11.1 The high–speed serial bus (HSSB) enables the high–speed transfer of
large amounts of data between a commercially available IBM PC or
OVERVIEW compatible personal computer and a CNC, by connecting them via a
high–speed optical fiber.
On the CNC, the HSSB interface board is installed in a minislot. On the
personal computer, an appropriate interface board is installed.
175
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
11.2 The use of the HSSB requires an IBM PC/AT compatible computer or
FANUC intelligent terminal. The machine tool builder or end user is
CAUTIONS required to procure and maintain the personal computer.
To enable the use of the HSSB, Windows 95/Windows NT4.0 must have
been installed on the personal computer.
FANUC owns the copyright for the HSSB device driver.
The software mentioned above and the contents of the related manuals
may not be used or reproduced in part or whole without the prior written
permission of FANUC.
NOTE
1 IBM is a registered trademark of IBM Corp. of the US.
2 Windows is registered trademarks of Microsoft Corp. of the
US.
3 The company and product names mentioned in this manual
are trademarks or registered trademarks of the respective
companies.
176
B–63833EN/02 11. HIGH–SPEED SERIAL BUS (HSSB)
11.3
CONNECTION
DIAGRAM
Series 0i
control unit
PC/AT compatible personal computer
COP7
Personal computer interface card
High–speed
serial bus
2ch A20B–8001–0582
2ch A20B–8001–0960
177
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
11.4
PERSONAL
COMPUTER CAUTION
SPECIFICATION 1 FANUC requires the customer to buy and maintain the
personal computer itself.
2 FANUC is not responsible for the proper working about the
personal computer itself and any troubles caused by using
the personal computer.
178
B–63833EN/02 11. HIGH–SPEED SERIAL BUS (HSSB)
179
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
11.7
PROCEDURE FOR
WARNING
INSTALLING Before starting to mount or remove a personal computer
PERSONAL interface board, switch off the personal computer and its
COMPUTER peripheral devices, and disconnect their power supply
INTERFACE BOARDS cables. Otherwise, there is a serious danger of electric
shock.
CAUTION
Do NOT touch the edge terminals (the contacts that engage
with a mating connector) of the interface board.
180
B–63833EN/02 11. HIGH–SPEED SERIAL BUS (HSSB)
Setting the rotary switch Using the rotary switch on the interface board in the personal computer,
on the interface board in set the base address of the I/O space for use by this HSSB board.
the personal computer 1. Setting of I/O Base Address in Case of Interface Board new Type 2 For
Personal computer (A20B–8001–0580, –0581, –0582, –0583)
Channel B (COP7B)
A20B–8001–0582
Channel A L,M,N = 0,2,9
181
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
182
B–63833EN/02 11. HIGH–SPEED SERIAL BUS (HSSB)
2nd HSSB(1ch)
1st HSSB(2ch)
PCI slot 1
PCI slot 2
PCI slot 3
PCI slot 0
Node ISA/PCI
0 ISA
1 ISA 1ch
2 PCI
2ch
3 PCI
4 ISA
1ch
5 PCI
6
7
3. Node Number
Node number is allotted manually as stated above.
183
11. HIGH–SPEED SERIAL BUS (HSSB) B–63833EN/02
11.8
RECOMMENDED
CABLES Personal computer
CNC interface card interface card
Optical fiber cable
COP7 COP7
(COP7A, COP7B)
Usable Optical Fiber Cable (The FSSB optical fiber cable to be used
outside of the cabinet.)
A66L–6001–0026#L1R003 : Cable Length = 1 m
A66L–6001–0026#L3R003 : Cable Length = 3 m
A66L–6001–0026#L5R003 : Cable Length = 5m
A66L–6001–0026#L7R003 : Cable Length = 7m
A66L–6001–0026#L10R03 : Cable Length = 10m
A66L–6001–0026#L15R03 : Cable Length = 15m
A66L–6001–0026#L20R03 : Cable Length = 20m
A66L–6001–0026#L30R03 : Cable Length = 30m
A66L–6001–0026#L50R03 : Cable Length = 50m
A66L–6001–0026#L100R3 : Cable Length = 100 m
NOTE
1 The optical fiber cables for the FANUC I/O Link cannot be
used with the HSSB.
2 Optical fiber cables cannot be cut or connected without
specialized equipment, usually not available to machine
tool builders. Therefore, use only the cables listed above.
184
B–63833EN/02 12. FANUC DNC2 INTERFACE
185
12. FANUC DNC2 INTERFACE B–63833EN/02
Series 0i
control unit
JD28A
RS232C
186
B–63833EN/02 12. FANUC DNC2 INTERFACE
12.2
DNC2 INTERFACE
CNC OPTION board Host computer (Example)
(RS–232–C)
JD28A
(PCR–E20LMDETZ–SL) DBM–25S
1 RD 11 SD 1 FG
14
2 0V 12 0V 2 SD
15
3 DR 13 ER 3 RD
16
4 0V 14 0V 4 RS
17
5 CS 15 RS 5 CS
18
6 0V 16 0V 6 DR
19
7 CD 17 7 SG
20 ER
8 0V 18 8 CD
21
9 19 9
22
10 20 10
23
11
24
12
25
13
Conceptional diagram
of signal connection
RS RS
CS CS
ER ER
DR DR
CD CD
SG SG
0V FG FG
FRAME
NOTE
When an IBM PC/AT is used, the RS signal goes low in the
reception phase. In this case, connect CS on the host side
to ER on the same side.
187
13. CONNECTION TO OTHER NETWORKS B–63833EN/02
188
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
189
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.2
CAUTIONS D The copyright of Windows 2000 and other software provided with the
CNC display unit with PC functions is owned by Microsoft
Corporation (USA), NeoMagic Inc., Phoenix Technologies Ltd., PFU
Co.,Ltd, and FANUC LTD.
– No part of the software described above, or its manuals, may be
used or reproduced without permission.
– No part of the software described above, or its manuals, may be
sold independently of the CNC display unit with PC functions.
– The software described above, and its manual, must be used under
the conditions described in the attached license agreement.
– The use of the CNC incorporating the CNC display unit with PC
functions shall imply that the user agrees to the conditions of the
license agreement described above.
*Windows2000 is a registered trademark of Microsoft corporation, USA
*Company name and product name mentions in this manual are
(registered) trademark of each company.
CAUTION
1 If an operation error or mishap occurs, the data on the hard
disk may be lost, even if all the installation conditions are
satisfied. Therefore, always maintain a backup copy of the
data on the hard disk in case the stored data is lost or
damaged.
Especially, the power–off on accessing the hard disk must
not be done because that possibility is very high. Please
concern for the end–users.
2 Be sure to finish the OS and the applications through the
proper operation of shutdown before turning the power off.
Without the above–mentioned operation, there is no
assurance of the following action. At worst, the command of
initializing the HDD will not work.
190
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.3
CONNECTION
ÅÅÅÅ
ÅÅÅÅ ÅÅÅÅÅ
ÅÅÅÅÅ ÅÅÅÅÅÅ
ÅÅÅÅÅÅ
FA
ÅÅÅÅ
ÅÅÅÅ ÅÅÅÅÅÅ
ÅÅÅÅÅÅ
ÅÅÅÅ ÅÅÅÅÅÅ
24VDC
ÅÅÅÅ ÅÅÅÅÅÅ
A 50 cm (approximate
length) flat cable for soft
ÅÅÅÅ
ÅÅÅÅ
keys is provided with the
CNC display unit with PC
functions.
ÅÅÅÅ
ÅÅÅÅ
ÅÅÅÅ
ÅÅÅÅ
ÅÅÅÅ
ÅÅÅÅ
MDI
Unit
ÅÅÅÅ
ÅÅÅÅ
ÅÅÅÅ ÅÅ Å
ÅÅÅÅ ÅÅ Å
ÅÅ Å
CK2
ÅÅÅÅ
ÅÅÅÅ ÅÅ Å
ÅÅÅÅ
ÅÅ
ÅÅÅÅ ÅÅ ÅÅÅ
ÅÅ
ÅÅÅÅ
ÅÅÅÅ
ÅÅ
JD45
ÅÅ
ÅÅÅÅ CK1
ÅÅÅÅ
Either an FA typewriter–style keyboard or an MDI unit can be connected.
191
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.4
GENERAL
CONNECTION
DIAGRAMS
14.4.1
CNC Display Unit with
PC Functions Having
Neither Soft Keys nor a
Touch Panel
192
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
Ô
Ô
: Optical link Module & Cable
: AMP(Dynamic)
Õ : AMP(mini–DIN6pins)
Õ
CNC Control Unit
Ÿ
: HONDA TSUSHIN (PCR 20pins)
POWER SUPPLY
: HIROSE DENKI(Flat Cable34pins)
HSSB I/F BOARD : HIROSE DENKI(Flat Cable40pins)
HSSB(COP7)
: AMP(EI Series 4pins)
: molex (5046–NA 3pin)
THE OTHER PCB
MDI(JA2) : Others
(CNH3)
ŽŽ FAN UNIT
3.5” HDD
HDD POWER (CN2B)
Unit
*2
*1
ÔÔÔ
FA FULL
HSSB (COP7) MOUSE
COLOR LCD PANEL
KEYBOARD
+24V INPUT (CP5)
ÔÔÔ *1
FULL KEYBOARD
KEY BOARD (CD32A)
MOUSE (CD32B) *1
MOUSE
232–1 (JD33)
ÕÕÕ
ÕÕÕ
Serial port 1
I/O
POWER
SUPPLY
ÕÕÕ
Serial port 2
232–2 (JD46)
USB port 1, 2 POWER
ŸŸÕ
ÕÕŸ ŸŸ
I/O
CENTRO (JD9) SUPPLY
ŸŸŸ ŸŸ
FDD (CD34) FLOPPY *1 POWER
DISK USB
SUPPLY
FDD POWER (CN2) DRIVE
*1 POWER
PRINTER
SUPPLY
PCMCIA CARD SLOT
PCMCIA
CARD
PCI SLOT 2 (CNP2) PCI EXTENSION BOARD
*1 These devices can be used only during application development. These cannot be installed in the control unit.
*2 A 3.5”HDD unit with a FAN unit must be mounted on the backside of a FA Full Keyboard.
193
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.4.2
CNC Display Unit with PC
Functions Having Soft
Keys but No Touch Panel
Ô : AMP(Dynamic)
(
POWER SUPPLY
: AMP(mini–DIN6pins)
HSSB I/F BOARD
HSSB(COP7) )
(
)
: HONDA TSUSHIN (PCR 20pins)
Ž
: HIROSE DENKI(Flat Cable34pins)
’
THE OTHER PCB : HIROSE DENKI(Flat Cable40pins)
’
MDI(JA2) : AMP(EI Series 4pins)
: molex (5046–NA 3pin)
: Others
POWER SUPPLY (+24VDC)
’
CNC display unit with PC functions Separate MDI
Soft–Key
%%&& ’ (CNK1)
FAN UNIT
ÔÔÔÔ
HSSB (COP7)
COLOR LCD PANEL
ÔÔÔÔ
+24V INPUT (CP5)
*1
FULL KEYBOARD
KEY BOARD (CD32A)
*1
MOUSE (CD32B) MOUSE
!!!!
232–1 (JD33) I/O
SUPPLY
Serial port 2
!!!!
232–2 (JD46)
USB port 1, 2 I/O POWER
""
!!""
!! ŸŸ
Ÿ
CENTRO (JD9) SUPPLY
""""ŸŸŸ
FDD (CD34) FLOPPY *1
USB POWER
DISK
SUPPLY
FDD POWER (CN2) DRIVE
*1 POWER
PRINTER
PCMCIA CARD SLOT
SUPPLY
PCI SLOT 1 (CNP1) PCI EXTENSION BOARD
PCMCIA
CARD
*1 These devices can be used only during application development. These cannot be installed in the control unit.
*2 A 3.5”HDD unit with a FAN unit must be mounted on the backside of a MDI.
194
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.4.3
CNC Display Unit with PC
Functions Having a Touch
Panel but No Soft Key
Ô
CNC Control
: Optical link Module & Cable
Ô
POWER SUPPLY : AMP(Dynamic)
’ : AMP(mini–DIN6pins)
.
’
HSSB I/F BOARD
HSSB(COP7) : HONDA TSUSHIN (PCR 20pins)
.
# : HIROSE DENKI(Flat Cable34pins)
THE OTHER PCB
! # : HIROSE DENKI(Flat Cable40pins)
!
MDI(JA2)
’ %
: AMP(EI Series 4pins)
’
: molex (5046–NA 3pin)
Separate MDI (CNK1)
(*1) : Others
,,-
POWER SUPPLY (+24VDC)
**+
HDD FAN (CN7)
FAN UNIT
**+
(CNH3)
3.5” HDD
HDD POWER (CN2B) Unit
*1 *2
ÔÔ
ÔÔÔ
FA FULL
MOUSE
HSSB (COP7) KEYBOARD
Ô
COLOR LCD PANEL
*2 FULL KEYBOARD
KEY BOARD (CD32A)
*2
MOUSE (CD32B) MOUSE
((
(((
232–1 (JD33) Serial port 1 (*3)
(((
Serial port 2 I/O POWER
232–2 (JD46)
USB port 1, 2 SUPPLY
CENTRO (JD9)
))
(()
( ŸŸ *2
))) ŸŸ
USB POWER
FDD (CD34) FLOPPY SUPPLY
DISK
FDD POWER (CN2) DRIVE *2 POWER
PRINTER
PCMCIA CARD SLOT
SUPPLY
PCMCIA
CARD
*1 Either Separate MDI or FA Full Keyboard is usable. Both cannot be used simultaneously. A 3.5”HDD unit with a FAN unit
must be mounted on the backside of a FA Full Keyboard or a MDI.
*2 These devices can be used only during application development. These cannot be installed in the control unit.
*3 RS232–C channel 1 is not usable because it is used by the Touch–Panel.
195
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.4.4
CNC Display Unit with PC
Functions Having a Touch
Panel and Soft Key
ÔÔ
CNC Control Unit
: Optical link Module & Cable
ÔÔ
POWER SUPPLY : AMP(Dynamic)
’’ : AMP(mini–DIN6pins)
..
’’
HSSB I/F BOARD
HSSB(COP7) : HONDA TSUSHIN (PCR 20pins)
..
’ ##
: HIROSE DENKI(Flat Cable34pins)
THE OTHER PCB
’
: HIROSE DENKI(Flat Cable40pins)
MDI(JA2)
%%
: AMP(EI Series 4pins)
%%
: molex (5046–NA 3pin)
: Others
’
POWER SUPPLY (+24VDC)
Stand–alone MDI
’
CNC display unit with PC functions
(CNK1)
%%& &
Soft–Key
##$$
HDD FAN (CN7) (CNK2)
ÔÔ
ÔÔÔÔ
HSSB (COP7)
ÔÔ
COLOR LCD PANEL
*1
FULL KEYBOARD
KEY BOARD (CD32A)
*1
MOUSE (CD32B) MOUSE
!!!!
!!
232–1 (JD33) Serial port 1 (*3)
!!!!
Serial port 2 POWER
232–2 (JD46) I/O
SUPPLY
""
!!""
!! ŸŸ
Ÿ
USB port 1, 2
CENTRO (JD9)
*1
""""ŸŸŸ
USB POWER
FDD (CD34) FLOPPY SUPPLY
DISK
FDD POWER (CN2) DRIVE *1 POWER
PRINTER
PCMCIA CARD SLOT
SUPPLY
*1 These devices can be used only during application development. These cannot be installed in the control unit.
*2 A 3.5”HDD unit with a FAN unit must be mounted on the backside of a MDI.
*3 RS232–C channel 1 is not usable because it is used by the Touch–Panel.
196
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.5
SPECIFICATIONS
14.5.1 When CNC display unit with PC functions is used, the following
environmental conditions (as measured top of the CNC display unit with
Installation
PC functions inside the cabinet) must be ensured for the CNC display unit
Environmental with PC functions unit installation.
Conditions
Ambient temperature Operating : +5 to +45_C
Non–operating : – 20 to +60_C
CAUTION
If an operation error or mishap occurs, the data on the hard
disk may be lost, even if all the installation conditions are
satisfied. Therefore, always maintain a backup copy of the
data on the hard disk in case the stored data is lost or
damaged.
Especially, the power–off on accessing the hard disk must
not be done because that possibility is very high. Please
concern for the end–users.
197
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
NOTE
Use of the FANUC I/O unit also requires +1 A.
(b) Timing
Input power can be turned on/off without relation to CNC power
on/off.
(2) Supply power
The CNC display unit with PC functions can supply power, as listed
below, to peripheral equipment. Check the amount of current drawn
by each unit you want to use.
198
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
NOTE
Above power consumption is reference. If peripherals are
connected or PCI extended boards are mounted, the power
consumption will increase. Also, please consider the
cabinet design and the cooling method which is most
suitable to the total power consumption.
14.5.3 Before switching off the CNC display unit with PC functions, terminate
all applications and the OS according to the normal shutdown procedure.
Shutdown
If the CNC display unit with PC functions is switched off while an
application or the OS is still running, the CNC display unit with PC
functions may fail to operate normally next time it is switched on. In the
worst case, the initialization command for the hard disk drive may
become inoperable.
199
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.6 The following three spaces are required around the CNC display unit with
PC functions.
INSTALLATION
A: Space for connecting cables.
SPACE Also, If you wish to exchange a battery or a fuse without removing
CNC display unit with PC functions from the machine panel, this
space A is required and it is necessary to be able to access to the battery
or the fuse from the rear side of the CNC display unit with PC
functions.
B: If PCI extension board exists, this space B is required for cable
connection. The dimension X depends on cables connected to the PCI
Extension board.
C: This space is required for airflow.
CNC display unit with PC functions consumes the power described at
“14.5.2. Power Specification” item 3) . Therefore, please install
cooling system in the cabinet with keeping space C.
14.6.1
Basic Unit 10.4″ LCD
Type
/// //////////////
Plate is ordered.
///
C
//////////////
C 50
/// //////////////
/// //////////
/// ////////// A
/// //////////
A
//////
/// //////////
//////
///
//////
27
//////////
///
///
////// ///
B X B
Fuse Battery
200
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.6.2
Basic Unit 12.1″ LCD
Type
60 In case that PCI Extension Board Fitting
/// ///////////////
Plate is ordered. 20
/// C
///////////////
/// ///////////////
C
/// /////////
///
///
A /////////
/////////
A
/// /////////
///
////// ////////////
////// /////////
////////////
57
B
//////
//////
B X
Fuse
///
/// Battery
Refer to APPENDIX about outline dimensions of the basic unit.
Unit: mm
14.6.3
Basic Unit 15.0″ LCD
Type
60 In case that PCI Extension Board Fitting
/// //////////////
Plate is ordered. 0
///
///
C
//////////////
////////////// C
/// ///////
///////
/// ///////
A
/////
/// /////////
A
///// /////////
///// /////////
77
B
///// //
///// //
X B
Fuse Battery
201
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.6.4 The HDD unit is mounted on the backside of the MDI or the FA
HDD Unit Full–Keyboard.
Reserve space C in the above figure.
And reserve space for connecting cables of HDD signal, HDD power,
FAN power , and MDI/FA full keyboard signal too.
The HDD unit itself also generates heat. Consider heat removal for both
the HDD unit and basic unit.
FA Full Keyboard
FAN HDD Unit or MDI Unit
/// //
///
///
C
//
///
///////////
//
/// //
//
/// //
/// //
C
/// //
/// //
/// // //
/// //
/// //
///
/// //
////////////
///
// //
//
////////////
30 20
202
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7
PERIPHERAL
EQUIPMENT AND
CONNECTION
14.7.1
Connector Layout
Diagram
PCMCIA
Card slot
(Display side)
Show from
CNP1
The back side
CNP2
CN2B CN2
JD33 JD46 JD9
CD32B CD32A
CP5 COP7
CNH3
CD34 CN7
Connector
Number Connector Name Function
CP5 +24V INPUT Main Power Input Soft–key
JD33 232–1 Serial Port 1 (Connector to sparate
JD46 232–2 Serial Port 2 +USB MDI)
JD9 CENTRO Parallel Port See 14.7.10.
COP7 HSSB HSSB
CD32B MOUSE Mouse
CD32A KEY BOARD Full Keyboard
CNH3 HDD HDD Signal
CN2B HDD POWER HDD Power Output
CN7 HDD FAN FAN for HDD
CD34 FDD FDD Signal
CN2 FDD POWER FDD Power Output
PCMCIA Card
CNP1 PCI SLOT1 PCI extension slot 1
CNP2 PCI SLOT2 PCI extension slot 2
NOTE
The Soft–Key only exists in the CNC display unit with PC
functions with Soft–Key.
203
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.7.2
Main Power Supply
Input
CP5
1 +24V
3
AMP
2–178288–3 (CASE)
1–175218–5 (CONTACT)
1
+24V +24V
2
0V 0V
NOTE
This power supply cable should be routed away from the
signal lines of the CNC display unit with PC functions.
204
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.3
Floppy Disk Drive
(Signal and Power
Supply)
CD34
1 0V 2 DENSEL 1 0V 2 DENSEL
3 0V 4 3 0V 4
5 0V 6 5 0V 6
7 0V 8 :INDEX 7 0V 8 :INDEX
9 0V 10 :MT0 9 0V 10 :DS0
11 0V 12 :DS1 11 0V 12 :DS1
13 0V 14 :DS0 13 0V 14 (RES)
15 0V 16 :MT1 15 0V 16 :MTR0N
17 0V 18 :DIR 17 0V 18 :DIR
19 0V 20 :STEP 19 0V 20 :STEP
21 0V 22 :WDATA B A 21 0V 22 :WDATA
23 0V 24 :WE 23 0V 24 :WE
25 0V 26 :TRK0 25 0V 26 :TRK0
27 0V 28 :WPRT 27 0V 28 :WPRT
29 0V 30 :RDATA HIF3BA–34D–2.54P 29 0V 30 :RDATA
31 0V 32 HDSEL produced by Hirose 31 0V 32 HDSEL
33 0V 34 :DSKCH Electric 33 0V 34 :DSKCH
CN2 J2
4321
1234 1 +12V 1 +5V
2 0V 2 0V
3 0V 3 (NC)
4 +5V 4 (NC)
AMP EI series 4–pin connector
Housing: 171822–4
Contact: 170262 and 170263
NOTE
1 This is a standard interface for the IBM PC compatible. Note the following:
D Only two floppy disk density modes (720 Kbytes and 1.44 Mbytes) are supported.
D The DENSEL signal level is fixed to low.
D Can not used floppy disk drive unit that needs 12V.
2 Commercial floppy disk drives are prone to compatibility problems with personal computers to
some degree. It is not guaranteed that the CNC display unit with PC functions can operate with
every commercial floppy disk drive. Machine tool builders are requested to check the
operability of the floppy disk drives they select. Keep in mind that commercial floppy disk drives
are neither dust–proof nor moisture–resistant.
3 The interface on the drive side shown above is only an example. Design an interface cable
according to the specification of the drive with which it is used.
205
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
1 1 1
0V 0V
2 2 2
DENSEL DENSEL
3 3 3
0V 0V
4 4 4
(NC) (NC)
5 5 5
0V 0V
6 6 6
(NC) (NC)
7 7 7
0V 0V
8 8 8
*INDEX *INDEX
9 9 9
0V 0V
10 10 16
*MT0 *0S0
11 11 15
0V 0V
12 12 14
*DS1 *DS1
13 13 13
0V 0V
14 14 12
*DS0 (RES)
15 15 11
0V 0V
16 16 10
*MT1 *MTRON
17 17 17 Panel–mount type
0V 0V
18 18 18 3.5″ floppy disk unit
CNC *DIR *DIR
19 19 19
CD34 0V 0V
20 20 20
*STEP *STEP J1
21 21 21
0V 0V
22 22 22
*WDATA *WDATA
23 23 23
0V 0V
24 24 24
*WE *WE
25 25 25
0V 0V
26 26 26
*TRK0 *TRK0
27 27 27
0V 0V
28 28 28
*WPRT *WPRT
29 29 29
0V 0V
30 30 30
*RDATA *RDATA
31 31 31 Pin assignment for
0V 0V
32 32 32 connector A on the
HDSEL HDSEL
33 33 33 previous page (see
0V 0V
34 34 34 Note)
*DSKCH *DSKCH
206
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.3.1 When using this unit on the machine, observe the following cautions:
Operating environment (1) Dust
Because the CNC display unit with PC functions is not covered with
panels, except for the front door section, it must be enclosed in a sealed
cabinet. While the door is open, dust can enter the floppy disk unit and
cabinet via the disk insertion slot. If the CNC display unit with PC
functions is installed in a dusty environment, more floppy disk failures
than normal may occur.
(2) Temperature
+5°C to +45°C (operating)
The operating temperature range for this unit is stricter than ordinary
units because of the restrictions imposed by the floppy disk. So, pay
special attention to the way it is cooled.
Avoid blowing air directly from a cooling fan, as dust in the air may
stick to the components of the unit.
14.7.3.2 Do NOT switch on the power to CNC display unit with PC functions
Handling precautions while a floppy disk is inserted, and especially when the floppy disk is
being accessed (LED is on). Machine tool builders are requested to
provide this information to their end users.
207
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.7.4
High–speed Serial Bus
(HSSB)
Optical fiber
COP7 COP7
208
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
NOTE
1 The high–speed serial bus cannot use an optical fiber cable
designed for the FANUC I/O link, FSSB extension line, or
serial spindle.
2 Machine tool builders cannot cut or extend optical fiber
cables. Select an appropriate type from the above list.
3 No FANUC I/O link junction adapter other than the low–loss
optical junction adapter can be used.
4 When using a low–loss optical junction adapter, be sure to
use a junction–only low–loss optical fiber cable together
with it.
5 Keep the total length of the junction adapter and
junction–only low–loss optical fiber within 60 m.
HSSB interface Translation CNC display unit with
board adapter PC functions
60m or less
14.7.5
Full Keyboard
Full keyboard
CNC display unit with PC functions (commercial model)
CD32A
(mini DIN6)
209
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
A02B–0236–C132#EC :
FA Full Keyboard (English) for 12.1” LCD type
A08B–0082–C150#JC :
FA Full Keyboard (Japanese) for 15.0” LCD type
A08B–0082–C150#EC :
FA Full Keyboard (English) for 15.0” LCD type
A08B–0082–C151#JC :
FA Full Keyboard (Japanese) for 15.0” LCD type (punch panel
built–in)
A08B–0082–C151#EC :
FA Full Keyboard (English) for 15.0” LCD type (punch panel
built–in)
NOTE
1 Commercial full keyboards are prone to compatibility
problems with personal computers to some degree. It is not
guaranteed that the intelligent terminal type 2 can operate
with every commercial full keyboard. Machine tool builders
are requested to check the operability of the full keyboards
they select. Keep in mind that general commercial full
keyboards are neither dust–proof nor moisture–resistant.
2 If an FA full keyboard is incorporated into the system, clamp
its cable at a point as close to it as possible so that the
weight of the cable is not applied directly to the connector.
210
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.6
Mouse
CNC display unit with PC functions
Mouse (commercial model)
CD32B
(mini DIN6)
Alternatively, FA full
keyboard
1) Recommended mouse
A86L–0001–0212 Standard PS/2 mouse (commercial model):
for development and maintenance use only
NOTE
1 Commercial mice are prone to compatibility problems with
personal computers to some degree. It is not guaranteed
that the intelligent terminal type 2 can operate with every
commercial mouse. Machine tool builders are requested to
check the operability of the mice they select. Keep in mind
that general commercial mice are neither dust–proof nor
moisture–resistant.
2 If an FA typewriter–style keyboard is incorporated into the
system, clamp its cable at a point as close to it as possible
so that the weight of the cable is not applied directly to the
connector.
3 The Mouse and The Touch–Panel can not be used
simultaneously.
211
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.7.7
Centronics Parallel
Port
JD9
(PCR–E20MD)
9 PE 19 :ERROR 9 STD7 27 0V
11 BUSY 29 0V
12 PE 30 0V
13 SLCT 31 :INIT
14 :AFD 32 :ERROR
15 33 0V
16 0V 34
1) Recommended cable conductor
A66L–0001–0284#10P: 10 pairs of 0.08 mm2 wires 17 FG 35
2) Recommended cable–end connectors (JD9 side)
PCR–E20FA (Honda Tsushin Kogyo Co., Ltd.) 18 36 :SLIN
FI30–20S (Hirose Electric Co., Ltd.)
FCN–247J020–G/E (Fujitsu Limited)
52622–2011 (Molex Japan)
NOTE
1 The interface on the printer side shown above is only an example. Design an interface cable
according to the specification of the printer with which it is used.
2 Commercial printers are prone to compatibility problems with personal computers to some
degree. It is not guaranteed that intelligent terminal type 2 can operate with every commercial
printer. Machine tool builders are requested to check the operability of the printers they select.
Keep in mind that general commercial printers are neither dust–proof nor moisture–resistant.
212
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.8
Serial Port 2 + USB
1 RD 11 SD 1 FG
14
2 0V 12 USB1_0V 2 SD
15
3 DR 13 ER 3 RD
16
4 0V 14 USB2_0V 4 RS
17
5 CS 15 RS 5 CS
18
6 USB1+ 16 USB2+ 6 DR
19
7 CD 17 USB2– 7 SG
20 ER
8 USB1– 18 USB2_5V 8 CD
21
9 RI 19 (+24V) 9
22 RI
10 (+24V) 20 USB1_5V 10
23
( ) : Used with FANUC 11
24
I/O device 12
25
13
* (Reserve) pins are not usable.
USB port 1
1 USB1_5V 4
2 USB1+ 3
2
3 USB1–
1
4 USB1_0V
USB port 2
1 USB2_5V 4
2 USB2+ 3
2
3 USB2–
1
4 USB2_0V
213
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
NOTE
1 The figure shows a sample host computer interface and
USB. Design the cable to suit the interface of the actual
device to be connected.
2 The +24V pins of the interface for CNC display unit with PC
functions shown above can be used only with the FANUC
I/O unit (FANUC CASSETTE, FANUC Handy File, etc.). Do
not use these pins for other purposes. Also, do not attempt
to simultaneously connect two or more FANUC I/O units to
one CNC display unit with PC functions.
3 Commercial USB devices cannot be guaranteed its proper
work with CNC display unit with PC functions. Careful
checking by the customer will be required. And please be
aware that those devices in the market are not almost
considered about waterproof and dustproof.
CAUTION
The standard punch panel for CNC cannot be used in CNC
display unit with PC functions.
214
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.9 For an CNC display unit with PC functions having a touch panel, the
Serial Port 1 touch panel controller uses serial port 1. So this connector cannot be used
for any other purpose. The touch panel controller is connected, using a
dedicated connector rather than JD33.
JD33
(PCR–E20MD) (DBM–25S)
1 RD 11 SD 1 FG
14
2 0V 12 0V 2 SD
15
3 DR 13 ER 3 RD
16
4 0V 14 0V 4 RS
17
5 CS 15 RS 5 CS
18
6 (RES) 16 (RES) 6 DR
19
7 CD 17 (RES) 7 SG
20 ER
8 (RES) 18 (RES) 8 CD
21
9 RI 19 (+24V) 9
22 RI
10 (+24V) 20 (RES) 10
23
( ): Used for a FANUC 11
24
I/O unit
12
25
* (RES) pins are not usable. 13
1) Recommended cable conductor
A66L–0001–0284#10P: 10 pairs of 0.08 mm2 wires
2) Recommended cable–end connectors (JD36 side)
PCR–E20FA (Honda Tsushin Kogyo Co., Ltd.)
FI30–20S (Hirose Electric Co., Ltd.)
FCN–247J020–G/E (Fujitsu Limited)
52622–2011 (Molex Japan)
215
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
NOTE
1 he interface on the host computer side shown above is only
an example. Design an interface cable according to the
specification of the host computer with which it is used.
2 The +24 V lines in the interface on the CNC display unit with
PC functions interface connection unit side shown above
can be used only for FANUC I/O units (such as the FANUC
cassette and FANUC Handy File). Do not use these lines
for any other purpose. Also, do not connect more than one
of these units to one CNC control unit. Otherwise, the +24
V power supply capacity may be exceeded.
3 Do not connect anything to those pins that are not labeled.
4 The standard punch panel for CNC cannot be used in CNC
display unit with PC functions.
14.7.10
Soft Keys
CNK2
50cm
216
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.7.11
PCMCIA Card
Door
PCMCIA
Card slot
Back side
PCMCIA card
(Type I, Type II)
NOTE
1 Only Type I or Type II PCMCIA card is usable. The following card cannot be used.
– Card–bus card
– Dual mode card (Card–bus mode/PCMCIA mode) with Card–bus mode
– Type III card
2 Care about the direction of the card, and insert certainly.
3 No card designed for use on +3.3 V can be used in the basic units (A08B–0082–B001 to
–B023).
CAUTION
If the door is opened, dust or coolant would enter and might cause any troubles. Please pay
attention.
217
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
14.7.12
Hard Disk Unit 1) Cable Connection
Connect HDD Signal cable to CNH3.
Connect HDD Power cable to CN2B.
Connect FAN cable to CN7.
Each cables are connected to HDD unit at exfactory.
2) Cable Length
HDD Power Cable: 50cm
HDD Signal Cable: 40cm
HDD FAN Cable: 65cm
CNH3 CN2B
CN7
HDD Signal
cable
HDD Power cable
FAN cable
HDD unit
FA full keyboard or MDI
unit
218
B–63833EN/02 14. CNC DISPLAY UNIT WITH PC FUNCTIONS
14.8
PCI EXPANSION
BOARD
Up to 106.68mm
Unit : mm
Up to 176.41mm
* If the fittings do not fit these extension boards, please change the
screw (B) positions.
219
14. CNC DISPLAY UNIT WITH PC FUNCTIONS B–63833EN/02
Press Down
Slot 1
Slot 2
Screw Point (A)
NOTE
Fanuc does not guarantee the proper workings or
maintenance of any PCI extension boards. And is not liable
to any trouble or damage incurred by use of any PCI
extended boards.
220
APPENDIX
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
223
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
224
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
Slot 1
Memory
card
Weight : 0.7kg
225
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
172
10
112 S=1/1
172
56 56
Main
board
I/O board
380
360
S=1/1
2 12
Weight : 3.0kg
226
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
220 max
Weight : 4.1kg
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
227
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Weight : 1.8kg
Panel cut drawing
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
228
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
Weight : 2.3kg
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
229
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Weight : 2.1kg
230
B–63833EN/02
Fig.U7
231
10.4″ TFT color LCD unit
Specification No. : A02B–0299–C060
Weight : 2.4kg
At the rear of the metal plate of the panel, the area
within 8 mm of the perimeter is left unpainted Panel cut drawing
A. EXTERNAL DIMENSIONS OF EACH UNIT
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Weight : 0.6kg
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
232
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
Weight : 1.1kg
Panel cut drawing
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
233
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
125
(With PCI Extension Board Fitting Plate)
60
(Without PCI Extension Board Fitting Plate)
25 2 20
Upper View
Paint Masking
(Mounting side of this
plate is unpainted in 8mm
4–φ4 width from the edge )
290
5
Maximum
PCI card
defined at
Connecting 4.
220
210
280
280
4–M3
204
(HOLE)
210
274
(Basic Unit is mounted from outside
of the panel)
Weight: 3.3kg
Unit : mm
Panel Cutting
Fig.U10 (a) 10.4″ TFT color LCD of CNC display unit with PC functions
234
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
125
(With PCI Extension Board Fitting Plate)
60
(Without PCI Extension Board Fitting Plate)
30 2 25
270
6–f4
5 165 165
5
Front View Side View
165 165
6–M3
(HOLE)
264
324
Weight: 4.5kg
Unit : mm
Panel Cutting
Fig.U10 (b) 12.1″ TFT color LCD of CNC display unit with PC functions
235
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
125
(With PCI Extension Board Fitting Plate)
60
(Without PCI Extension Board Fitting Plate)
35 2 30
Paint Masking
Upper View (Mounting side of this
plate is unpainted in 8mm
400 width from the edge )
5
155
320
155
5 195 195
304
(HOLE)
310
384
(Basic Unit is mounted from outside
of the panel)
155
Weight: 6.0kg
Panel Cutting Unit : mm
Fig.U10 (c) 15.0″ TFT color LCD of CNC display unit with PC functions
236
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
10.7
50.5
290
43.5
220
40 24.5
45.5
14.5
9 42.4
70max.
5 9
65
51.8
87.6
83.1
63
b
34
54 177 35
69 79
Fig.U11 (a) Stand–alone type standard MDI unit for CNC display unit with PC functions (10.4” LCD, vertical type)
237
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
10.7
230 50.5
43.5
220
40
24.5
45.5
14.5
4–f4 9 42.4
5 9
70max.
5
* The depth dimension assumes that
the HDD unit is installed.
35
21.8
57.6
53.1
63
b
16
24 177
18
39 79
Fig.U11 (b) Stand–alone type standard MDI unit for CNC display unit with PC functions (10.4” LCD, horizontal type)
238
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
1550"40 250"40
290 20 60.6
220
10 6
4–φ5
5
32
a
5
a
a: M5 10mm
b: M5 10mm (Frame GND)
60 56
a
30
b Weight : 3.5 kg
40
a (Unit :mm)
20
239
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
1550"40 250"40
340 20 60.6
220
10 6
6–φ5
5
32
a
5
a
a: M5 10mm
b: M5 10mm
(Frame GND)
110
54
a
30
b
Weight : 3.7 kg
40
a
(Unit :mm)
20
240
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
1550"40 250"40
2
400
60.6
20
220
6–φ5
5.5
26
34 5 35
13
140
86 Hole of
179
168
Connector
27 Panel
b
59
20
80
5.5
2–φ5
Weight :3.9 kg Unpaint rear side
(Unit :mm) (φ10)
b: M5 10mm (Frame GND)
241
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
280
- FA Full Keyboard 10.4" LCD Type
4–M3
210
204
HOLE
274
6–M3
204
210
HOLE
162
324
390
- FA Full Keyboard 15.0" LCD Type
6–M3
204
HOLE
210
242
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
(Unit : mm)
Full Keyboard 106key (A86L–0001–0211)
Note: These units can be used only during application development and maintenance ,and this is not
dust proof. .Ambient temperature during operation is 0_C–40_C.
243
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Cap Ball
1800"190
(Unit : mm)
Note: This unit can be used only during application development and maintenance ,and this is not
dust proof. .Ambient temperature during operation is 0_C–40_C.
Fig.U14 Mouse
Specification No. : A86L–0001–0212
244
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
5
4–φ3.6
FDD
J2
150
140
ACRYLIC
104
WINDOW
J1
5
5 70 5 145
80
(Unit : mm)
4–M3
140
134
64
(HOLE)
70
Panel Cutting
Mounting direction
When using the floppy disk unit attached to the machine, mount the floppy disk unit in one of the following directions:
245
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
–0582 –0583
Weight: 0.2 kg
Fig.U16 (a) High–speed serial bus interface board type 2 (PC) (ISA bus version)
Specification No. : A20B–8001–0583 (1 CH)
A20B–8001–0582 (2 CH)
0961 0960
Fig.U16 (b) Interface Board for Personal Computer (PCI bus version)
Specification No. : A20B–8001–0960 (2 CH)
A20B–8001–0961 (1 CH)
246
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
MS connector: MS3102A–20–29P
247
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
8.35
f80.0
f55.0
50.0
30.0
M4X8.0
60.0
On the f72 circumference
PULSE GENERATOR
11.0
FANUC LTD
0V 5V A B
M3 screw terminal
120.0°
248
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
90 38.0
25
Y Z X1 X10X100
X 4
M3 screw terminal
140
100.0
39.0
M3 screw terminal
90 38.0
25
Z 4 X1 X10 X100
Y
X 5
M3 screw terminal
140
100.0
39.0
M3 screw terminal
249
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
COP10B COP10A
JF101(JF105)
JF102(JF106)
JF103(JF107)
JF104(JF108)
CP11
JA4A
250
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
Plus terminal
with 3–M3
screw holes
103
93
Minus terminal
with 3–M3
screw holes
FANUC
40
4–f4.3 mounting hole
Arrow view A
14.1
106.3
92.2
13.2
78 78
251
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Main unit
Cover
103
115
M4 tap × 4
70
81 93
145
252
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
80
5
13
5
125
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
80
Dimensions of panel cutting
100
115
20
4–M3
253
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
40
20 13
5
125
5
At the rear of the metal plate of the panel, the area within 8 mm of the perimeter is left unpainted
100
20
2–M3
254
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
150
255
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Earth stud
(M4)
6–φ4
5
80
70
60
5 280 5
5
290
70
270
6–M3
140 140
70
66
274 Unit : mm
Weight : 0.6kg
Panel cut drawing
256
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
Earth stud
(M4)
Unit = mm
Weight: 0.6kg Panel cut drawing
257
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Connectors
Fig. title Specification No. Fig. No.
AMP connector (3) for +24 V power supply AMP1–178288–3 Fig.C3 (c)
AMP connector (4) for +24 V power supply AMP2–178288–3 Fig.C3 (d)
Honda connector (for distribution I/O connection printed circuit board) MRH–50FD Fig. C9
258
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
A
n
2 1.27 1
7.3
n n)1
2
Display
HONDA
7
15.1
1.27
B
A B
PCR–E20FS 21.65 11.43
259
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
16.25 15_
11.43
1.27
Note
This connector does not
10 9 8 7 6 5 4 3 2 1 have contacts for positions
11,13,15,17, and 19.
5.5
2.2
9.2
1.7
20 19 18 17 16 15 14 13 12 11
13.35
19.2
Tab for
shield
connection
7
(4)
4.3
3
(3)
5
8.5
1.8 (1)
(2)
2.4 2.4
A A
Section AA S 20 18 16 14 12
(Standard 1/10)
See from the back (soldering side)
10 8 6 4 2
9 7 5 3 1
260
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
9.5
21 11.4
(1)
HONDA
(2)
37
30
(3) (6)
(5)
(4)
261
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
21±0.3
11.5±0.3
9.5±0.2
(5)
(6)
(4)
37"0.5
17.5"0.3
(3)
30±0.3
(2) (1)
262
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
9.5
21 11.4
(2)
F
C020–02
37
30
Cable clamp
Screw
Lock lever
263
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
264
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
TYPE : AMP1–178128–3
22.8
16.3
19.24
0.6
10.16
5.08
7.15
4.05
6.55
3.1
3 2 1
Circuit No.
265
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
TYPE : AMP2–178128–3
Circuit No.
(29.7)
DIMENSION
3 2 1
AMP D–3
16.3" 0.3
(19.24)
" 0.3
7.15
4.05
6.55
3.1
3 2 1
Cricuit No.
266
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
TYPE : AMP1–178288–3
X 22.8
16.3
16.7
0.6
7.62
3.81
7.15
4.05
6.55
3.1
3 2 1
Circuit No.
267
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
TYPE : AMP2–178288–3
0.6
7.15
6.55
3 2 1
Circuit No.
268
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
" 0.5
" 0.2
5.5
3.4
–AMP
" 0.2
(f2.6)
2.5
269
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
(2)
(4)
(1)
(3)
C
(5)
A (D)
(B)
Symbol Number of
Specification A (B) C (D) terminals
MR–20LMH (Plug)
39.3 44.9 39.8 17 20
MR–20LFH (Jack)
MR–50LMH (Plug)
67.9 73.5 44.8 18 50
MR–50LFH (Jack)
Symbol Name
Outer diameter of the cable
1 Connector cover MR–20L dia.10mm max
2 Cable clamp MR–50L dia.16mm max
3 Stopper
4 Screw for cable clamp
Plug (MR–20, 50MH)
5
Jack (MR–20, 50FH)
270
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
271
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
13 2–M2
A
B
(1)
2.4
18.1
(2)
8.5
(3)
14 15 16 17 18 19 20
HONDA
8 9 10 11 12 13
1 2 3 4 5 6 7
Number of
A B
terminals
MR–20RMH 32.8 27.8 20
MR–50RHF 61.4 56.4 50
Symbol Name
1 Cable clamp
2 Screw 2.6dia.×8
3 Connector (MR–20,–50MH)
272
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
13 2–M2
B
A
(1)
2.4
19.9
8.4
10.9
(2)
(3)
1 2 3 4 5 6 7
HONDA
8 9 10 11 12 13
14 15 16 17 18 19 20
Number of
A B terminals
MR–20RMH 32.8 27.8 20
MR–50RMH 61.4 56.4 50
Symbol Name
1 Cable clamp
2 Screw 2.6dia.×8
3 Connector ( MR–20,– 50FH)
273
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
HONDA
MR–50MH
19 20 21 22 23 24 25 26 27 28 29 30 31 32 (50–core,plug)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
MR–50FH
HONDA
19 20 21 22 23 24 25 26 27 28 29 30 31 32 (50–core, jack)
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
14 15 16 17 18 19 20
HONDA
MR–20MH
8 9 10 11 12 13 (20–core,plug)
1 2 3 4 5 6 7
1 2 3 4 5 6 7
HONDA
MR–20FH
8 9 10 11 12 13 (20–core, jack)
14 15 16 17 18 19 20
274
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
5.08
5
38 max.
48 max.
4
3
1
2
1
7 max.
24.9
275
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
HIF3BB
15.6
14.4
1.27 1.27 1.09
1.27
A A A
2.54
D
6.0
A A’ B
3.6
6.0
6.0
1.27 2.54
B’ 3.81
B
D
3.8 :1
3.5
:2
:3
5.1
7.0 3.5
7.0
10.5
0.95
0.3
8.5
1.05
2.3 2.3
2.7
C 3.5
4.5
Dimensions
No.of
Description A B C D
contact
HIF3BB–34D–2.54R 34 47.75 40.64 41.91 43.23
ROW A
ROW B
01 03 05 07 09
02 04 06 08 10
OUTVIEW FROM CONNECTOR SIDE.
50PINS
ROW A
ROW B
01 03 05 07 09 11 13 15 17 19 21 23 25
02 04 06 08 10 12 14 16 18 20 22 24
OUTVIEW FROM CONNECTOR SIDE.
276
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
+0.2
18
2 (pitch)
±0.15
13
0
20.5 –0.3
+0.3
21.6 0
277
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Section A–A
Contact position
Product name
278
B–63833EN/02 A. EXTERNAL DIMENSIONS OF EACH UNIT
H
J
A 53.0 D 7.8 G 10.7
B 38.3 E 12.6 H 1.2
C 47.0 F 41.3 J 0.8
A
C A–A cross section
B F
A 10
E D G
6.1 10
A 10
2–3.05f
10.8
Small round
M2.6 P0.45 screw Interlock screw head screw
1.2groove
6.1
12.7
1.2
6.2 Spring washer
279
A. EXTERNAL DIMENSIONS OF EACH UNIT B–63833EN/02
Honda MR type, 50 pins, male, connection printed circuit board soldering type connector
Type No. Honda Tsushin Kogyo Co., Ltd.
MRH–50FD
280
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
281
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
282
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
B.3 Cable connectors consist of a connector main body and housing. The
models listed below are available. Those connectors not marked with an
CABLE asterisk are currently being mass–produced as manufacturer’s standard
CONNECTORS models. Those marked with an asterisk are produced according to custom
specifications by FANUC.
283
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
PCR–E20FS (Honda) Soldering type connector for general signals. This is suitable for producing
cable assemblies in small quantities, as well as on–site.
FI40B–20S (Hirose) Has the same number of pins as the FI40–20S, but features a wider soldering
(formerly, FI40A–20S) pitch, facilitating soldering and enabling the use of thicker wires. Its reinforced
pins allow wires as thick as #17AWG to be soldered to the FI40B–20S (wires no
thicker than #20AWG can be used with the FI40A–20S). Note, however, that a
thick wire, such as #17AWG, should be used with a more robust housing like
the FI–20–CV6.
FI40B–2015S (Hirose) Features a wider soldering pitch, attained by using the space provided by thin-
(formerly, FI40–2015S) ning out some pins. Also features tougher pins, compared with its predecessor,
the FI40–2015S. These pins can be soldered to wires as thick as #17AWG,
provided that the cable diameter does not exceed 8.5 mm.
D Housings
Housing model (manufacturer) Supplementary description
FI–20–CV5 (Hirose) Should be used with the FI40B–20S. This is a plastic housing designed for use
with a cable that is 9.2 mm in diameter.
FI–20–CV6 (Hirose) Should be used with the FI40B–20S. This housing, however, can be used with
a thicker cable (such as 10.25 mm) than is possible with the FI–20–CV5. Its
components are die cast.
FI–20–CV2
D FI40–20S (6.2mm in diameter) Those
listed on
FI40B–20S FI–20–CV5
the left
(formerly FI40A–20S) (9.2mm in diameter)
can be
FI–20–CV6 used.
(10.25mm in diameter)
284
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
B.4
RECOMMENDED
CONNECTORS,
APPLICABLE
HOUSINGS, AND
CABLES
Table B.4 Recommended connectors, applicable housings, and cables
Connector name
FANUC–approved FANUC–approved Compatible cable (cable diameter)
referenced in the
connector housing FANUC development Remark
Connection
(manufacturer) (manufacturer) FANUC specification number
Manual
NOTE
*1 Cable A66L–0001–0286 has been recommended for use as a pulse coder cable. It can be
up to 20 m long. Two cables, A66L–0001–0402 and A66L–0001–0403, have recently been
developed. A66L–0001–0402 and A66L–0001–0403 can be as long as 30 m and 50 m,
respectively. (See Fig. 4 for detailed specifications.)
Both cables have the same level of oil and bending resistance (cable, 100 mm in diameter,
capable of withstanding at least 10 million bending cycles) as conventional cables, and are
UL– and CSA–certified.
285
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
Press–mount type
connector assembly
tools and jigs
Connector model FANUC–approved
Press–mounting
referenced in the connector Wire forming tool Remark
tool
Connection Manual (manufacturer)
FHAT–918A
FCN–237T–T062/H
NOTE
1 Those tools indicated by shading are available from FANUC (specification number
A02B–0120–K391).
2 The tools available from each manufacturer are specifically designed for use with the
connectors manufactured by that manufacturer.
286
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
Materials for cable Machine tool builders are required to manufacture or procure the
assemblies materials for the cable assemblies to be used with their products. FANUC
recommends the following materials as being suitable for interface
connectors. Individual machine tool builders are encouraged to contact
each cable manufacturer for themselves, as required.
FANUC
Material Use Constitution specification Manufacturer Remark
number
287
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
Pitch mm 20 or less
Thickness mm 1.0
288
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
The numbers assigned to the wires correspond to the numbers in the table at right.
Dot mark
color
Pair No.
(1 pitch)
The numbers assigned to the wires correspond to the numbers in the table at right.
289
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
Pitch mm 20 or less
Thickness mm 0.3
Braid density % 70
290
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
NOTE
The maximum outside diameter applies to portions other
than the drain wire.
Drain wire
Red
0.18–mm2 twisted pair wire
7
6 White 1
Red Black 0.5–mm2 insulated wire
291
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
(c) Specifications
Item Specification
Insulation Color White, red, black Red, black White, red, black Red, black
(polyester)
Typical thickness (mm) 0.16 0.23 0.16 0.25
292
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
Item Specification
Electrical Conductor resistance 103 or lower 25.5 or lower 103 or lower 15.0 or lower
performance Ω/km (20°C)
Cable cross
section Tape Braided shielding
ÅÅÅÅÅÅÅÅ
ÅÅÅÅÅÅÅÅ
ÅÅÅÅÅÅÅÅ
White Red Twisted pair A
ÅÅÅÅÅÅÅÅ
Red
Black
ÅÅÅÅÅÅÅÅ
Red Black Red Black
ÅÅÅÅÅÅÅÅ
Solid wire B
ÅÅÅÅÅÅÅÅ
White Black
Black
Red
ÅÅÅÅÅÅÅÅ
Drain
Sheath
293
B. 20–PIN INTERFACE CONNECTORS AND CABLES B–63833EN/02
Specification – A66L–0001–0371
Number of Conductors – 5
Diamter mm 0.48
Thickness mm 0.71
Diamter mm 1.90
Density % 95 or more
Thickness mm 0.2
Thickness mm 0.15
Diamter mm 2.6
Shield braiding Element wire diameter (material) mm 0.12 (tinned soft copper wire)
Thickness mm 0.3
Diameter mm 7.8
294
B–63833EN/02 B. 20–PIN INTERFACE CONNECTORS AND CABLES
1 Red RD
2 Red RD
INTERPOSITION
9 Black BK 3 Green GN
4 Green GN
10 Black BK
SHEATH
8 White WH 6 Blue BU
7 White WH 5 Blue BU
.
.
.
Ω
Resistor
Check .
every pin .
.
PCR–E20LMD (Honda)
PCB connector This is a standard product from the manufacturer.
295
C. CONNECTION CABLE (SUPPLIED FROM US) B–63833EN/02
Maximum
Cable type Use and condition cable length
(m)
NOTE
1 The maximum cable lengths listed above apply only when
the respective recommended cables stated in the text are
used. If a non–recommended cable is used, the maximum
cable length may not be guaranteed. Cables other than
those listed above are used between units in the i series
CNC. See the respective descriptions in this manual for
details of these cables.
2 This cable can be extended to up to 15 m if it is used within
the cabinet.
296
B–63833EN/02 C. CONNECTION CABLE (SUPPLIED FROM US)
MDI
signal cable
Control unit
A02B–0120–K810 5m
(JA2)
µ PCR–E20F
MDI unit
(CK1)
CRT/PDP
video signal
cable
Monochrom
CRT
power cable
LCD Power
supply cable
Control unit
A02B–0120–K823 5m
(CP1B)
µ
LCD unit AMP2–17288–3
(CP1B)
Control unit
A02B–0236–K843 5m
(CP1B)
µ
I/O Unit
SMS3PNS–5
(CP31)
297
C. CONNECTION CABLE (SUPPLIED FROM US) B–63833EN/02
Power supply
cable for AMP2–178288–3
stand–alone type
LCD unit
A02B–0166–K880 55 m
Control unit
(CPD2)
µ
Stand–alone type AMP1–178288–3
LCD (CP1A)
Manual pulse
generator cable
(for one unit)
FI40–2015S
Control unit
A02B–0120–K847 7m
(JA3)
µ M3 crimp style terminal
Manual pulse
generator
terminal board
Manual pulse
generator cable
(for two units)
Manual pulse
generator cable
(For 3 MGs)
I/O Link
cable
Control unit
A02B–0120–K842 5m
(JD1A)
µ PCR–E20FA
I/O unit
(JD1B)
298
B–63833EN/02 C. CONNECTION CABLE (SUPPLIED FROM US)
Spindle signal
cable A03B–0807–K801 5m
Control unit
(JA7A)
µ PCR–E20FA
Spindle A03B–0807–K802 10m
amplifier (JA7B)
Voltage regulator
A02B–0124–K830 5m
(24VDC)
µ
Control unit
AMP1–178288–3
(CP1A)
299
D. OPTICAL FIBER CABLE B–63833EN/02
The Series 0i/0i Mate uses optical fiber cables for the following
interfaces. This table lists the usable combinations.
Interface Recommended Maximum allowable Applicable junc- Remark
optical cable transmission distance tion adapter
NOTE
For printed–circuit boards with the following former ordering
information, the maximum allowable transmission distance
with –0026#L~ is lowered to 50 m, and connection with
A63L–0020–0004 is impossible.
·A20B–8001–0580 ·A20B–8001–0581
·A20B–8001–0640 ·A20B–8100–0100
300
B–63833EN/02 D. OPTICAL FIBER CABLE
Unit: mm
7
21
Code
Unit: mm
8.2
21
Code Bush
Reinforced cover
301
D. OPTICAL FIBER CABLE B–63833EN/02
A66L–6001–0023# A66L–6001–0026#
L50R03 50.0 m
L100R03 100.0 m
L200R03 200.0 m
2. Cable selection
D Always use an external cable (A66L–6001–0026#) when the cable
is to be laid outside the power magnetics cabinet or main unit
cabinet, where it may be pulled, rubbed, or stepped on.
D Use an external cable when part of the cabling is to be subject to
movement. For example, when connecting a portable operation
pendant box to the power magnetics cabinet, the use of an external
cable is desirable because the cable is likely to be bent, pulled, or
twisted repeatedly even though frequent system operation is not
expected. However, the force likely to be applied when the cable
is installed or moved for maintenance purposes does not need to be
taken into consideration.
D Use an external cable in locations where sparks or flame are a
danger. Although the internal cord type cable
(A66L–6001–0023#) is covered by nonflammable resin, the cover,
if exposed to frame for a long time, may melt, allowing the fiber
cable inside to burn.
D Use an external cable when the cable is expected to be pulled with
considerable force during installation (the force applied to the cable
must be within the specified tensile strength limit at all times). For
example, even though installing a cable in a cable duct can be
regarded as internal cabling, a cable of the appropriate type must
be selected according to the tensile force to be applied to the cable
during installation.
D Both the internal cord type and external cables have the same oil
and heat resistance properties.
302
B–63833EN/02 D. OPTICAL FIBER CABLE
4. Handling precautions
(1) Protection during storage
When the electrical/optical conversion module mounted on the
printed circuit board and the optical fiber cable are not in use, their
mating surfaces must be protected with the lid and caps with which
they are supplied. If left uncovered, the mating surfaces are likely
to become dirty, possibly resulting in a poor cable connection.
303
D. OPTICAL FIBER CABLE B–63833EN/02
Fig. D.3 Protection of electrical/optical conversion module and optical fiber cable (when not in use)
304
B–63833EN/02 D. OPTICAL FIBER CABLE
pull it. Because the combined tensile strength of the two cords is
only 14 kg, however, avoid applying too great a force to the cable
during installation, regardless of whether you have taken the
protective measures.
Optical connector
Reinforcing cover Optical connector
Tape Tape
2 cords combined
D Take care to keep both parts of the optical connector (cable side and
PCB side) clean. If they become dirty, wipe them with tissue paper or
absorbent cotton to remove dirt. The tissue paper or absorbent cotton
may be moistened with ethyl alcohol. Do not use any organic solvent
other than ethyl alcohol.
D Fix the reinforcing cover of the external cable or the cord binding
portion of the internal cord type cable by using a cable clamp, as
shown in Fig. D.5, to prevent the weight of the optical fiber cable
from being applied directly to the connecting part of the optical
connector.
(Recommended cable clamp):
Recommended cable clamps are listed below. Use a clamp
that grasps the optical cable lightly; the clamp should not
apply excessive pressure to the cable.
For an external cable:
CKN–13SP (with sponge)(Kitagawa Industry Co., Ltd.)
For an internal cord type cable:
MN–1 (Kitagawa Industry Co., Ltd.)
305
D. OPTICAL FIBER CABLE B–63833EN/02
306
B–63833EN/02 D. OPTICAL FIBER CABLE
32"0.3
10.16
R1.6
6.6
8.2
21"0.5
3.2 42"0.5
18.2"0.5
2.2
Mounting board
NOTE
Up to one relay points are permitte.
307
D. OPTICAL FIBER CABLE B–63833EN/02
32"0.5
10.16
R1.6
6.6
8.2
21"0.3
3.2 42"1.0
18.1
2.2
Mounting board
NOTE
Only one relay point is permitted.
308
B–63833EN/02 D. OPTICAL FIBER CABLE
NOTE
Ferrule: Movable metal at the tip of an optical connector; the
fiber is bonded to the ferrule.
Ferrule
Protective cover
Optical cable
Optical connector
309
D. OPTICAL FIBER CABLE B–63833EN/02
10.Cleaning
If the optical fiber junction adapter, optical–to–electrical conversion
module, or optical cable are soiled, clean them according to the
following procedures.
D Cleaning the optical fiber junction adapter and optical-to-electrical
conversion module
First, clean the entire housing by wiping it with a cloth moistened
with, or by washing it in, ethyl alcohol or HCFC141B (alternative
CFC; High Shower spray can DS–2168, manufactured by Sun
Hayato). Similarly, wash the two sleeves in the adapter or wipe
them with a cotton swab or the like.
310
B–63833EN/02 D. OPTICAL FIBER CABLE
311
E. ATTACHING A CRT PROTECTIVE COVER B–63833EN/02
312
B–63833EN/02 E. ATTACHING A CRT PROTECTIVE COVER
Bottom cover
To be inserted under the
metal plate
313
F. MEMORY CARD INTERFACE B–63833EN/02
Overview Data I/O internal to the CNC can be performed for maintenance through
the memory card interface in the control unit. This appendix F describes
the memory card interface for data input/output.
314
B–63833EN/02 F. MEMORY CARD INTERFACE
NOTE
The PSMCIA interface on the CNC display unit for with PC
functions is not included.
315
F. MEMORY CARD INTERFACE B–63833EN/02
Purpose
Vendor Specification Capacity Remarks
For Data For Data
Input/Output server
NOTE
1 If a card other than the above is used, the operation is not
guaranteed.
2 The cards for 3.3 V cannot be used.
3 The cards for 5 and 3.3 V (automatic switching) can be
used.
316
B–63833EN/02 F. MEMORY CARD INTERFACE
4.Miscellaneous
D The flash ATA card uses a quick format.
If your flash ATA card has not been formatted, do so using a
personal computer.
D It is impossible to use ATA cards with the memory card access
function of a C executor application.
317
B–63833EN/02 Index
[Numbers] Configuration, 1
Connecting DI/DO, 106
20–pin Interface Connectors and Cables, 281
Connecting I/O Devices, 59, 60
9I CRT Display Unit Interface, 52
Connecting Machine Interface I/O, 101
Connecting the FANUC Servo Unit β Series with I/O
Link, 168
[A] Connecting the High–speed Skip (HDI), 74
Action Against Noise, 15 Connecting the Manual Pulse Generator, 71
Address Assignment by Ladder, 170 Connecting the signal ground (SG) of the control unit,
Analog Spindle Interface, 81 18
Attaching a CRT Protective Cover, 312 Connection, 122, 169, 191
Connection Cable (Supplied from US), 296
Connection Diagram, 177
[B] Connection of Battery for Separate Absolute Detector,
95
Basic Unit 10.4I LCD Type, 200
Connection of FANUC I/O Link by Electric Cable,
Basic Unit 12.1I LCD Type, 201 127
Basic Unit 15.0I LCD Type, 201 Connection of One to Two Serial Spindles, 79
Batteries for CNC Display Unit with PC Functions Connection of Power Supply, 88
(3VDC), 46 Connection to CNC Peripherals, 49
Battery, 44 Connection to FANUC I/O Link, 120
Battery for Absolute Pulse Coder Built into the Motor Connection to Machine Operator’s Panel, 129
(6VDC), 48
Connection to Manual Pulse Generators, 72
Battery for Memory Backup (3VDC), 44
Connection to other Networks, 188
Battery for Separate Absolute Pulse Coders (6VDC),
47 Connection to the Display Unit/MDI Unit, 50
Board–mounted Connectors, 282 Connection to the High–speed Skip (HDI), 75
Built–in I/O Card Connection, 104 Connection to the Operator’s Panel I/O Module, 151
Connection to the Servo Amplifiers, 84
Connection to the Standard MDI Unit, 54
[C] Connections, 131
Cable Clamp and Shield Processing, 23 Connector (on the cable side) specifications, 138
Cable Connectors, 283 Connector Layout Diagram, 29, 203
Cable for Power Supply to Control Unit, 43 Connector Locations, 97
Cable Lead–in Diagram, 27 Connector Locations of Main Panel B, 141
Cable Length for Manual Pulse Generator, 167 Connector Pin Arrangement, 105
Cable Length When Only One Manual Pulse Genera- Control Unit, 26
tor is Used, 73 Cooling by Heat Exchanger, 13
Centronics Parallel Port, 212
CNC Display Unit with PC Functions, 189
CNC Display Unit with PC Functions Having a Touch [D]
Panel and Soft Key, 196
Design and Installation Conditions of the Machine
CNC Display Unit with PC Functions Having a Touch Tool Magnetic Cabinet, 11
Panel but No Soft Key, 195
Detachable key top, 147
CNC Display Unit with PC Functions Having Neither DI (General–purpose Input Signal) Connection, 154
Soft Keys nor a Touch Panel, 192
DI (input signal) connection, 135
CNC Display Unit with PC Functions Having Soft
Keys but No Touch Panel, 194 DI Signals and Receivers, 103
i–1
Index B–63833EN/02
[F]
FANUC DNC2 Interface, 185
[L]
FANUC Handy File Connection, 70
Linear Scale Interface, 89
Floppy Disk Drive (Signal and Power Supply), 205
Full Keyboard, 209
[M]
Main panel B specification, 143
[G] Main Power Supply Input, 204
General Connection Diagrams, 192
Manual Pulse Generator Connection, 166
General of Hardware, 4
Maximum Number of Units that can be Connected,
General–purpose DI signal definition, 144 170
General–purpose DO signal definition, 144 Meaning of key symbols, 145
Ground, 17 Memory Card Interface, 314
Mouse, 211
[H]
Handling Precautions, 179 [N]
Handling precautions, 207 Name Of Each Part of Control Unit, 2
Hard Disk Unit, 218 Noise Suppressor, 22
HDD Unit, 202 Notes on Installing a Separate Detector Interface Unit,
99
Heat Loss of Each Unit, 14
i–2
B–63833EN/02 Index
[R] [V]
Recommended Cables, 184 Varied MDI key switch, 55
Recommended Connectors, Applicable Housings, and Various LCD Units Interface, 53
Cables, 285
i–3
Revision Record
01 July, 2002