I/O Relay

G7T CSM_G7T_DS_E_3_1

Slim-styled I/O Relay Saves Space in Panel


• SPST-NO, SPST-NC, and SPDT contact forms available for
output (SPST-NO only for input).
• Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
• All Output Relays provide a long endurance (1,000,000
operations at 5 A), while all Input Relays provide microswitching
power (100 μA at 1 V).
• Approved by UL and CSA standards.

Refer to Safety Precautions for All Relays.

Ordering Information
Classification Model Rated voltage
Input (bifurcated contact) SPST-NO G7T-1122S (see note 2) 12 VDC
24 VDC
100/110 VAC
200/220 VAC
Output (single contact) SPST-NO G7T-1112S (see note 2) 12 VDC
24 VDC
SPST-NC G7T-1012S 12 VDC
24 VDC
SPDT G7T-112S 12 VDC
24 VDC

Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in Specifications.
Example: G7T-112S 12 VDC
Rated voltage
2. The G7T-1122S and G7T-1112S are approved by UL and CSA. Contact your OMRON representative for the coil ratings of other
models. The G7T-112S cannot be used in place of the G7TC. The G7T-112S can only be used with the P7TF-05 Socket.

Model Number Legend


G7T-@@@@S
1 2 3 4 5

1. No. of Contact Poles


2. Contact Form
No indication: Transfer contact
Number: Number of NO contacts
3. Contact Mechanism
1: Single contact
2: Bifurcated contact
4. Enclosure Construction
2: Casing
5. Terminal Type
S: Plug-in Terminal

1
G7T
■ Accessories
Socket
Applicable Relay Model
All G7T I/O Relay and the G3TA models. P7TF-05

P70 Indicator Module


Remove the transparent style strip of the Socket and mount this module. It will function as an operation indicator with surge suppression.

Model Applicable Relay coil voltage Remarks


For AC Relay P70A 100/110 VAC Surge suppressing system with varistor
200/220 VAC
For DC Relay P70D 12/24 VDC Surge suppressing system with diode

Note: 1. Order the Indicator Module that is suited to the Relay coil voltage.
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. Input current (reference values):
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA

Specifications
■ Ratings
Coil Ratings (Common to Both Input and Output)
Item Rated current Coil Must operate Must release Max. voltage Power
resistance voltage voltage consumption
Rated voltage (V) 50 Hz 60 Hz
AC 100/110 8.2/9 mA 7/7.7 mA 8,700 Ω 80% max. of 30% min. of rat- 110% of rated 0.7 VA
200/220 4.1/4.5 mA 3.5/3.85 mA 33,300 Ω rated value ed value value
DC 12 42 mA 290 Ω 80% max. of 10% min. of rat- 110% of rated 0.5 W
24 21 mA 1,150 Ω rated value ed value value
100/110 5 mA 20,000 Ω 80% max. of 10% min. of rat- 110% of rated 0.5 W
rated value ed value value

Note: 1. The rated current and coil resistance values are measured at a coil temperature of 23°C. Tolerances of AC rated current are +15%, –20%
and tolerances of coil resistance are ±15%.
2. Four rated voltages or currents are available to single AC models used with the P7TF-05 Socket. Only three rated voltages or currents
are available, however, when the Relay is used in place of the G7TC.
3. The operating characteristics values are for a coil temperature of 23°C.
4. The maximum voltage is one that is applicable to the Relay coil instantaneously at 23°C and not continuously.

Contact Ratings
Classification For input For output
Item Resistive load Inductive load Resistive load Inductive load
(cosφ = 1) (L/R = 7 ms) (cosφ = 1) (cosφ = 0.4, L/R = 7 ms)
Contact mechanism Crossbar bifurcated Single
Contact material AgAu-clad Ag AgSnIn
Rated load 1 A at 24 VDC 0.5 A at 24 VDC 5 A at 24 VDC 2 A at 24 VDC
2 A at 220 VAC 1 A at 220 VAC
Rated carry current 1A 5A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 1A 5A
Failure rate (reference value) 100 μA at 1 VDC 10 mA at 5 VDC

2
G7T
■ Characteristics
Contact resistance (see note 2) 50 mΩ max.
Operate time (see note 3) 15 ms max.
Release time (see note 3) 15 ms max.
Max. operating frequency Mechanical:18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load)
Insulation resistance (see note 4) 100 MΩ (at 500 VDC)
Dielectric strength Between coil and contacts: 2,000 VAC, 50/60 Hz for 1 minute
Between contacts of same polarity: 1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance Malfunction: 200 m/s2
Mechanical endurance 50,000,000 operations
Electrical endurance (see note 5) Input:10,000,000 operations (10 mA) or 50,000 operations (1 A) with resistive load
2,500,000 operations (10 mA) or 20,000 operations (1 A) with inductive load
Output:1,000,000 operations with rated load
Error rate (level P) Input: 100 µA at 1 VDC
(Reference value) Output: 10 mA at 5 VDC
(see note 6)
Ambient temperature Operating:–40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85% (with no icing or condensation)
Weight Approx. 17 g

Note: 1. The above values are all initial values.


2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The operate and the release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient tem-
perature of 23°C.
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
strength.
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 120 operations per minute.

■ Socket Ratings
Features
• Easily mounts or dismounts the G7T I/O Relay.
• Also mounts the Indicator Module (with surge suppressing function).
• Only 19 mm in width.
• Terminals corresponding to the NO and NC contacts of a Relay are arranged on top of the Socket to enhance maintainability.
• Also permits mounting of the G3TA Solid-state I/O Relay.

Specifications
Model P7TF-05
Contact resistance 10 mΩ max.
Dielectric strength 2,000 VAC for 1 minute
Insulation resistance 1,000 MΩ (at 500 VDC)
Vibration resistance 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance 1,000 m/s2
Ambient temperature Operating: 0°C to 55°C
Ambient Humidity Operating: 5% to 85%
Weight Approx. 28 g

3
G7T
Engineering Data
Maximum Switching Power Electrical Endurance
(Output Model with Life of Output Relay Input Relay
1,000,000 Operations)
5,000 5,000

Endurance (x 104 operations)

Endurance (x 104 operations)


Switching current (A)

50
3,000 3,000
30 AC inductive load
cosφ = 0.4
10 1,000 1,000
AC resistive load 700 700
5 500 24 VDC resistive load 500
3 300 24 VDC inductive load 300
(L/R 7 ms)
24 VDC resistive
1 100 100 load
70 70
0.5 DC resistive load 50 50
0.3 30 30
DC inductive load
L/R = 7 ms 220 VAC resistive load 10 24 VDC L/R 7 ms
0.1 10
7 7
5 220 VAC inductive load (cosφ = 0.4) 5
0.05
0.03 3 3

0.01 1 1
1 3 5 10 30 50 100 300 500 1,000 0 1 2 3 4 5 6 7 8 0 10 mA 50 mA 100 mA 0.5 A 1A
Switching Switching
Switching voltage (V) Switching current (A) current (mA) current (A)

4
G7T
Dimensions
Note: All units are in millimeters unless otherwise indicated.

10 max.
SPST-NO Type
G7T-1122S (for input)
G7T-1112S (for output) Terminal Arrangement/
Internal Connections
(Bottom View)

32 max.
39 max.

Four, 1-dia. holes

10 max.

29 max.
33.5 max.

SPST-NC Type 10 max.


G7T-1012S (for output)
Terminal Arrangement/
Internal Connections
(Bottom View)

32 max.
39 max.

Four, 1-dia. holes

10 max.

29 max.
33.5 max.
SPDT Type
10 max.
G7T-112S (for output)
Terminal Arrangement/
Internal Connections
(Bottom View)

32 max.
39 max.

Four, 1-dia. holes

10 max.

Note: This Relay cannot be used as an I/O relay terminals


29 max. and must be used in combination with the exclusive
33.5 max. P7TF-05 Socket.

5
G7T
■ Accessories
Socket
P7TF-05

Dimensions
19 max. Internal Connections
Five, M3.5 × 8 (Top View)
square screws with M3 or M4 screw hole *
washers

71.5 max.

M3 screw hole

Note: If the I/O SSR or Indicator Module is used,


be aware that the polarity of terminal 1 is
positive.
59 max.
* We recommend that you insert washers when
mounting with M3 screws. A washers are not
required when mounting with M4 screws.

Indicator Module (with Surge Suppressing Function)


P70
Dimensions
Internal Connections
29.5 max.

8.5 max.

32.5 max.
39 max.

Two, 1-dia. holes

Safety Precautions
Refer to Safety Precautions for All Relays.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

6
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

2010.8
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.