Ordering Information
Classification Model Rated voltage
Input (bifurcated contact) SPST-NO G7T-1122S (see note 2) 12 VDC
24 VDC
100/110 VAC
200/220 VAC
Output (single contact) SPST-NO G7T-1112S (see note 2) 12 VDC
24 VDC
SPST-NC G7T-1012S 12 VDC
24 VDC
SPDT G7T-112S 12 VDC
24 VDC
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in Specifications.
Example: G7T-112S 12 VDC
Rated voltage
2. The G7T-1122S and G7T-1112S are approved by UL and CSA. Contact your OMRON representative for the coil ratings of other
models. The G7T-112S cannot be used in place of the G7TC. The G7T-112S can only be used with the P7TF-05 Socket.
1
G7T
■ Accessories
Socket
Applicable Relay Model
All G7T I/O Relay and the G3TA models. P7TF-05
Note: 1. Order the Indicator Module that is suited to the Relay coil voltage.
2. The Indicator Module for DC Relays has a multiple power supply common to 12 and 24 VDC.
3. Input current (reference values):
100/110 VAC: 1.14 to 1.38 mA
200/220 VAC: 1.40 to 1.71 mA
12/24 VDC: 4.83 to 5.90 mA
Specifications
■ Ratings
Coil Ratings (Common to Both Input and Output)
Item Rated current Coil Must operate Must release Max. voltage Power
resistance voltage voltage consumption
Rated voltage (V) 50 Hz 60 Hz
AC 100/110 8.2/9 mA 7/7.7 mA 8,700 Ω 80% max. of 30% min. of rat- 110% of rated 0.7 VA
200/220 4.1/4.5 mA 3.5/3.85 mA 33,300 Ω rated value ed value value
DC 12 42 mA 290 Ω 80% max. of 10% min. of rat- 110% of rated 0.5 W
24 21 mA 1,150 Ω rated value ed value value
100/110 5 mA 20,000 Ω 80% max. of 10% min. of rat- 110% of rated 0.5 W
rated value ed value value
Note: 1. The rated current and coil resistance values are measured at a coil temperature of 23°C. Tolerances of AC rated current are +15%, –20%
and tolerances of coil resistance are ±15%.
2. Four rated voltages or currents are available to single AC models used with the P7TF-05 Socket. Only three rated voltages or currents
are available, however, when the Relay is used in place of the G7TC.
3. The operating characteristics values are for a coil temperature of 23°C.
4. The maximum voltage is one that is applicable to the Relay coil instantaneously at 23°C and not continuously.
Contact Ratings
Classification For input For output
Item Resistive load Inductive load Resistive load Inductive load
(cosφ = 1) (L/R = 7 ms) (cosφ = 1) (cosφ = 0.4, L/R = 7 ms)
Contact mechanism Crossbar bifurcated Single
Contact material AgAu-clad Ag AgSnIn
Rated load 1 A at 24 VDC 0.5 A at 24 VDC 5 A at 24 VDC 2 A at 24 VDC
2 A at 220 VAC 1 A at 220 VAC
Rated carry current 1A 5A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 1A 5A
Failure rate (reference value) 100 μA at 1 VDC 10 mA at 5 VDC
2
G7T
■ Characteristics
Contact resistance (see note 2) 50 mΩ max.
Operate time (see note 3) 15 ms max.
Release time (see note 3) 15 ms max.
Max. operating frequency Mechanical:18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load)
Insulation resistance (see note 4) 100 MΩ (at 500 VDC)
Dielectric strength Between coil and contacts: 2,000 VAC, 50/60 Hz for 1 minute
Between contacts of same polarity: 1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance Malfunction: 200 m/s2
Mechanical endurance 50,000,000 operations
Electrical endurance (see note 5) Input:10,000,000 operations (10 mA) or 50,000 operations (1 A) with resistive load
2,500,000 operations (10 mA) or 20,000 operations (1 A) with inductive load
Output:1,000,000 operations with rated load
Error rate (level P) Input: 100 µA at 1 VDC
(Reference value) Output: 10 mA at 5 VDC
(see note 6)
Ambient temperature Operating:–40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85% (with no icing or condensation)
Weight Approx. 17 g
■ Socket Ratings
Features
• Easily mounts or dismounts the G7T I/O Relay.
• Also mounts the Indicator Module (with surge suppressing function).
• Only 19 mm in width.
• Terminals corresponding to the NO and NC contacts of a Relay are arranged on top of the Socket to enhance maintainability.
• Also permits mounting of the G3TA Solid-state I/O Relay.
Specifications
Model P7TF-05
Contact resistance 10 mΩ max.
Dielectric strength 2,000 VAC for 1 minute
Insulation resistance 1,000 MΩ (at 500 VDC)
Vibration resistance 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance 1,000 m/s2
Ambient temperature Operating: 0°C to 55°C
Ambient Humidity Operating: 5% to 85%
Weight Approx. 28 g
3
G7T
Engineering Data
Maximum Switching Power Electrical Endurance
(Output Model with Life of Output Relay Input Relay
1,000,000 Operations)
5,000 5,000
50
3,000 3,000
30 AC inductive load
cosφ = 0.4
10 1,000 1,000
AC resistive load 700 700
5 500 24 VDC resistive load 500
3 300 24 VDC inductive load 300
(L/R 7 ms)
24 VDC resistive
1 100 100 load
70 70
0.5 DC resistive load 50 50
0.3 30 30
DC inductive load
L/R = 7 ms 220 VAC resistive load 10 24 VDC L/R 7 ms
0.1 10
7 7
5 220 VAC inductive load (cosφ = 0.4) 5
0.05
0.03 3 3
0.01 1 1
1 3 5 10 30 50 100 300 500 1,000 0 1 2 3 4 5 6 7 8 0 10 mA 50 mA 100 mA 0.5 A 1A
Switching Switching
Switching voltage (V) Switching current (A) current (mA) current (A)
4
G7T
Dimensions
Note: All units are in millimeters unless otherwise indicated.
10 max.
SPST-NO Type
G7T-1122S (for input)
G7T-1112S (for output) Terminal Arrangement/
Internal Connections
(Bottom View)
32 max.
39 max.
10 max.
29 max.
33.5 max.
32 max.
39 max.
10 max.
29 max.
33.5 max.
SPDT Type
10 max.
G7T-112S (for output)
Terminal Arrangement/
Internal Connections
(Bottom View)
32 max.
39 max.
10 max.
5
G7T
■ Accessories
Socket
P7TF-05
Dimensions
19 max. Internal Connections
Five, M3.5 × 8 (Top View)
square screws with M3 or M4 screw hole *
washers
71.5 max.
M3 screw hole
8.5 max.
32.5 max.
39 max.
Safety Precautions
Refer to Safety Precautions for All Relays.
In the interest of product improvement, specifications are subject to change without notice.
6
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
2010.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/