53 1001274 06 FixedRackMountKit
53 1001274 06 FixedRackMountKit
53 1001274 06 FixedRackMountKit
16 November 2012
53-1001274-06
*53-1001274-06*
2 of 12
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: china-info@brocade.com
European Headquarters
Brocade Communications Switzerland Srl
Centre Swissair
Tour B - 4me tage
29, Route de l'Aroport
Case Postale 105
CH-1215 Genve 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: china-info@brocade.com
Document History
Title
Publication number
Summary of changes
Date
53-0000244-03
December 2003
53-0000244-04
July 2004
53-0000244-05
January 2005
53-0000244-06
June 2005
53-1000244-07
October 2005
53-1000244-08
February 2006
53-0000244-09
December 2006
53-0000244-10
January 2008
53-0000244-11
March 2008
53-0000244-12
August 2008
53-1001274-01
March 2009
53-1001274-02
July 2009
53-1001274-03
August 2009
53-1001274-04
December 2010
3 of 12
Title
Publication number
Summary of changes
Date
53-1001274-05
September 2011
53-1001274-06
November 2012
4 of 12
Contents
This document provides instructions to install a 1U, 1.5U, or 2U switch (or SAN Router) in a 19-in. (48.3 cm) EIA rack
using the Fixed Rack Mount Kit. The document is organized as follows:
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tool requirements and parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
6
6
8
Introduction
The supported switches are listed in Table 1. The switch can be installed so that the port side is either flush with the
front posts or recessed from the front posts. A recessed position allows a more gradual bend in the fiber-optic cables
connected to the switch.
TABLE 1
Supported switches
Switch height
Switch model
1U
Brocade 300
Brocade 5100
Brocade 7800
Brocade 8000
Brocade VA-40FC
Brocade VDX 6710-54
Brocade VDX 6720-24
Brocade VDX 6730-32
2U
Brocade 5300
Brocade 6520
Brocade Encryption Switch
Brocade VDX 6720-60
Brocade VDX 6730-76
5 of 12
Installation requirements
Allow 15 to 30 minutes to complete this procedure. Note the following requirements to ensure correct installation
and operation:
Provide space in a 19-in. (48.3 cm) EIA rack, as required for the switch type, with a minimum distance of 28.25
in. (71.76 cm) and a maximum distance of 29.88 in. (75.90 cm) between the front and back posts.
Verify that the additional weight of the switch does not exceed the rack weight limits.
Ensure that an electrical branch circuit with the following characteristics is available:
- Required voltage and frequency as indicated in the hardware reference manual (200-230 VAC is always
preferred).
Ensure that all equipment installed in the rack is grounded through a reliable branch circuit connection. Do not
rely on a secondary connection to a branch circuit, such as a power strip.
6 of 12
FIGURE 1
7 of 12
Installation procedure
ATTENTION
The switch must be turned off and disconnected from the fabric during this procedure.
NOTE
Although this document describes how to install single-height (1U) and double-height (2U) switches, the illustrations
show a single-height switch as a typical installation.
Complete these tasks to install the switch in a four-post rack:
8 of 12
FIGURE 2
9 of 12
FIGURE 3
NOTE
The figure above is shown with a recessed mounting configuration on the left and a flush mounting configuration on
the right. You can select either mounting option.
10 of 12
FIGURE 4
11 of 12
FIGURE 5
12 of 12