KCD2 RR Ex1
KCD2 RR Ex1
KCD2 RR Ex1
Features Assembly
PWR
Function
S1
I II
required accuracy.
The input card of the control system measures the same load Removable terminals
as if it were connected directly to the resistance in a hazardous green
area.
Connection
286931_eng.xml
KCD2-RR-Ex1
Date of issue 2019-05-28
4+ 6+
3+ 8+ mA
1- 7-
2- 5-
Release date 2019-05-28 13:43
9+
10-
24 V DC
Zone 0, 1, 2 24 V DC Zone 2
Div. 1, 2 Power Rail Div. 2
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
1
Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical data KCD2-RR-Ex1
General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection Power Rail or terminals 9+, 10-
Rated voltage Ur 19 ... 30 V DC
Ripple within the supply tolerance
Rated current Ir < 20 mA
Power consumption 0.35 W (24 V and 1 mA sense current)
Input
Connection side field side
Connection terminals 1, 2, 3, 4
Line fault detection yes , at Pt100
Lead resistance ≤ 10 % of resistance value
Transmission range 0 ... 10 mA
Available voltage 9V
Line fault detection 8 nA
Output
Connection side control side
Connection terminals 5-, 7-, 6+, 8+
Current 0 ... 10 mA
Available voltage 0 ... 4.2 V
Fault signal < 10 Ω or > 400 Ω, depending on lead disconnected (measuring current ≤ 1 mA)
> 400 Ω, terminal 3 lead disconnected in 2-/4-wire (measuring current ≤ 0.3 mA)
Transfer characteristics
Accuracy 0.1 %
Deviation 4-wire
Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable)
Im < 1 mA: accuracy reduces in proportion to Im.
e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).
3-wire
Im ≥ 1 mA: (±0.1 % - 0.1 Ω Offset) or ± 0.2 Ω (the larger value is applicable)
Im < 1 mA: accuracy reduces in proportion to Im.
e. g. Im = 0.1 mA: (±1 % - 0.1 Ω Offset) or ± 1.1 Ω (the larger value is applicable)
Influence of ambient temperature Im ≥ 1 mA, Rm ≥ 100 Ω : 0.01 %/K in the range -20 ... +60 °C (253 ... 333 K)
Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm
Rise time signal response time ≤ 2 ms (10 ... 90 %)
response to application of Im: Rm > 50 Ω and Im < 5mA: < 5ms
response to application of Im: Rm > 30 Ω and Im < 5mA: < 10ms
response to application of Im: Rm > 18 Ω and Im < 5mA: < 20ms
Galvanic isolation
Input/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Input/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Output/power supply functional insulation, rated insulation voltage 50 V AC
Indicators/settings
Display elements LED
Control elements DIP-switch
Configuration via DIP switches
286931_eng.xml
2
Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical data KCD2-RR-Ex1
3
Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical data KCD2-RR-Ex1
Additional information
Function
When a signal converter, a DCS or PLC is connected to terminals 5, 6, 7, and 8 (control side), the measuring current is
transferred to terminals 2 and 4 (field side). The resulting voltage at terminals 1, and 3 is transferred to terminals 5, 6, 7, and 8.
In the case of fast multiplex input cards, transmission problems might be experienced in connection with low resistance values
and/or high sensor currents. For data see rise time.
The quoted accuracy is for a 4-wire technique connection. The accuracy in 3-wire technique will depend on the matching of the
line resistance.
Connection types control side (safe area)
2-wire technique 3-wire technique 3-wire technique 4-wire technique
negative positive
measuring line measuring line
8 6 5 7 8 6 5 7 8 6 5 7 8 6 5 7
+ + - - + + - - + + - - + + - -
Measurement range
The resistance repeater can convey a maximum of 10 mA and a maximum of 7 V. The maximum connectable resistance value
can be calculated with the following equations
• Resistance value = 4.2 V / measuring current
• Resistance value = 9 V / measuring current - 758 Ω
Use the smaller of these two resistance values as maximum allowed load.
The measuring current is determined by control.
Measuring current
I (mA)
10
286931_eng.xml
4
Date of issue 2019-05-28
0.5
2 4 6 8 8.4 10 12 kΩ
Max. resistance
of sensor
Release date 2019-05-28 13:43
4
Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Technical data KCD2-RR-Ex1
5
Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com