Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Operation Manual: Multihead Weigher

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

Multihead Weigher

Operation Manual
Contents
Chapter 1. Preface 1
Chapter 2. Notice 2
2.1 Model Instruction 2

2.2 Working Environment 2

2.3 Transportation & Storage 3

2.4 Working Environment 3

Chapter 3. Specifications 4
Chapter 4. Working Theory 5
Chapter 5. Operation 6
5.1 Start up 6

5.2 Start to Run 8

5.3 Calibration 10

5.4 Program Setup 11

5.5 System Setup 17

5.6 Records 23

5.7 Manual Test 24

Chapter 6. Trouble Shooting & Settlement 27


Chapter 7. The Meaning of the Indicated Color & Character 29
Chapter 8. Remarks of KJ1&KJ2 Cable 30
Chapter 9. Crate-Open & Check 31
9.1 Check the machine and spare parts under guide of Packing List. 31

9.2 Check if the following documents are attached with the machine 31

9.3 Crate Open 31

Chapter 10. Machine Structure 32


10.1 Main Components 32

10.2 External Specification 33

10.3 Main Components 35


Multihead Weigher Operation Manual

Chapter 1. Preface
Thank you for using HS-H Series Multihead Weighers.

HS-H Series Mulithead Weighers are automatic weighing equipment by using Modular control system to
achieve the high speed, accuracy and stable performance, different functions could be expanded according
to customer's requirements.

To ensure the proper use as well as safe operation, please read this instruction manual carefully before
using.

Please keep this manual in proper place so that you can use it for maintenance or repair in future. If you
have any problem while using our multihead weigher, please feel free to contact our service department, we
will try our best to provide you a professional and all-round service.

•1•
Multihead Weigher Operation Manual

Chapter 2. Notice
2.1 Model Instruction
HS - H10L1.6

Hopper Volume(1.6=1.6L;2.5=2.5L)

Litre

Heads( 10=10 head,14=14 head)

H SeriesH Series

Abb. of Company Name

2.2 Working Environment


• Temperature: 0℃ ~40℃ ;
• Humidity: 35%-85%(No dewing);
• Power: AC 220V/110V ± 10%V 50Hz(60Hz);
• Keep away and shield off away from the disturb source;
• Installation place: On rigid, horizontal and no vibration surface;
• Earth line: Make sure the machine is connected to the earth;
• It works under aseptic and non-dust plant when packaging food products;
• Leave enough space around the machine for maintenance.

•2•
Multihead Weigher Operation Manual

2.3 Transportation & Storage

• Only professional engineer is allowed to repair the machine when failure happens;
• Turn off the power before cleaning, moving and repairing the machine;
• To avoid body injury, it is prohibited to touch the hopper or pan while machine is running;
• No bumping or strong pressure on weigh hoppers;
• Direct current for the connection signals with other equipments (packing machine,
conveyor,etc.) should be no more than 30V, the overloading current no more than 100mA.

2.4 Working Environment


• The machine should be treated carefully while transporting, installation and disassembling. No
throwing, bumping or reversing. Prevent from strong vibration and raining.
• The machine should be kept in ventilated room with temperature range of -10℃ ~50℃ , humidity no
more than 80% and kept away from corrosion gas.

•3•
Multihead Weigher Operation Manual

Chapter 3. Specifications
Machine Model HS-H10 HS-H14 HS-H14L5.0

Single Weigh Range 10-3000G 10-3000G 10-5000G

Accuracy ± 0.1 - ± 2.0G ± 0.1 - ± 2.0G ± 0.1 - ± 3.0G

Power AC220V/110V ±10% 50Hz(60Hz)

Max. Speed 70WPM 120WPM 70WPM

Weigh HP Volume 1600mL/2500mL 1600mL/2500mL 5000mL

Control System Modular Unit

Touch Screen 7inch touch screen

1090L*1130W*1830H 1130L*1130W*1830H 2300L*1530W*1721H


Packaging Dimension
(mm) (mm) (mm)

Packaging Weight 420KG 480KG 800KG

Optional Parts Dimple plate / Timing hopper / Diverter chute gates / 10 inch touch screen

•4•
Multihead Weigher Operation Manual

Chapter 4. Working Theory


The product is fed to the upper storage funnel where it is dispersed to the feed hoppers by main vibrator
pan. Each feed hopper drops the product into a weigh hopper beneath it as soon as the weigh hopper
becomes empty.

The weigher's computer determines the weight of product in each individual weigh hopper and identifies
which combination contains the weight closest to the target weight .The multihead weigher opens all the
hoppers of this combination and the product falls, via a discharge chute, into a packaging machine or,
alternatively, into a distribution system which places the product, for example, into trays. The working
principle of the multihead weigher is shown as chart4-1-1.

Conveyer
Upper storage funnel

Main Vibrator Pan


Multihead weigher

Linear Vibrator Linear Vibrator

Feed Hopper Feed Hopper

Weigh Hopper Weigh Hopper

Weigh Hopper Combination

Discharge

Packaging Mahince
conveyer.etc.

Chart 4-1-1

•5•
Multihead Weigher Operation Manual

Chapter 5. Operation
Our machine panel is friendly-use design. All functions will work within 0.5-1 second after be touched.

5.1 Start up
It will automatically enter into the language choice menu after turning on the machine, shown as chart 5-1-1.

Chart 5-1-1

Press password bar to input password, passwords be set as several level of authorities.

a) Level 0, no password, permit to enter Menu of “Manual Test”,“Record”,“Help”, ”Zero”,“Empty”,


“Clean”, “Run”.
b) Level 1, Password: 138138, permit to enter all Menu except “System Setup”, “Calibration”;
c) Level 2, Password: 168168, permit to enter all Menu except “System Setup”;
d) Level 3, Password: 178178, permit to enter all Menu; it’s highest management of password;

•6•
Multihead Weigher Operation Manual

Choose language and press the language button to enter the main menu, shown as chart 5-1-2.

Chart 5-1-2

1. Help :
Press the "Help" where you can read explanation of parameters by checking its different page.
2. Zero:
1) After turning on the machine, an attention of "PLS Press Zero" will be displayed on the main menu,
which reminds that you must make manual Zero operation.
2) Press "Zero", all feed hoppers and weigh hoppers will open in turn to empty the rest products in the
hoppers. After 3 seconds, each load cell has an auto zeroing.
3) After auto zeroing, the attention of "PLS Press Zero" will auto-disappear and display the current date
and time on the screen.
3. Empty:
Press "Empty" to empty products. Main vibrator, linear vibrators, feed hoppers and weigh hoppers will
run continuously to clear up the hoppers. Press "Empty" again to exit. To ensure the weighing accuracy,
after the "Empty" operation stop, it will make Auto-zero again.
4. Clean:
Press "Clean" , all hoppers will stay open at its maximum angle. Press "Clean" again to exit.
5. Exit:
Return to language choice menu.

•7•
Multihead Weigher Operation Manual

5.2 Start to Run


On the main menu, press "Start to Run" to enter the menu "Run" , shown as chart 5-2-1.

Chart 5-2-1

1. Preset Sp:
Preset Speed: Set an expected speed for multihead weigher according to the actual packaging speed.
The revised speed will be auto-saved after Exit.
2. Amplitude:
Main AMP:
Press central button, it will display a keyboard, Adjust the main vibrator amplitude at running status.
The larger the value is, the stronger the vibration is. The revised main AMP will be auto-saved after Exit.
Range: 1-99.
Lin. AMP:
Press the button of each hopper, Adjust the linear vibrator amplitude at running status. Press the button
and it will display keyboard to change the value. Eachamplitude can be adjusted independently. The
larger the value is, the stronger the vibration is. The revised Lin AMP will be auto-saved after Exit. Range:
1-99.
SET ALL:
Set all linear amplitude at the same time.

•8•
Multihead Weigher Operation Manual

Chart 5-2-2

3. Run:
Run or pause the machine.
4. Main Menu:
Return to "Main Menu". During running, you have to press "Pause" first.
5. Meaning of each Letters during menu “Run”

Letter Meaning
C Be choose to combination;
D Hopper be disabled;
E Head modular control boards in communication error;
U Single hopper weight exceed target weight and be forced to discharge;
L Single hopper weight less than weight of “Average hopper weight %”
Q Hopper which no combination will be forced to discharge;
R Weight is ready;
T Communication error for weighing modular;
Z Auto zeroing;
A In course of feeding material

Reminder: If “E”, “D”,”T” occurs, please go to chapter 9 to refer “Trouble shooting & Settlement”.
Press “Run” again to stop running then press “Main Menu” to exit.

•9•
Multihead Weigher Operation Manual

5.3 Calibration
Press "Calibration" on main menu to enter into "Calibration" menu, shown as chart 5-3-1.

Chart 5-3-1

1. Poise Wt(g):
Input the real weight value of Poise which equipped with machine. Our standard poise is 500gram.
2. Hopper No.
Input the number of hopper which should be calibrated.
3. Zero:
Make sure there is no any products in weigh hopper, then press “Zero”, to make load cell conducting
zeroing, if value display as 0.0g, Zero is successfully done.
4. Full:
Put the poise in the weigh hopper gently and then press "Full" to confirm. Waiting 1~2 seconds, if value
same as poise weight, Calibration is done successfully. When take away poise, the display value should
be 0.0g±0.1g. Otherwise please do “Zero” and “Full” operation one more time.
5. How to make calibration:
• Input the poise weight value,500g. Our standard poise is 500gram.
• Input the number of hopper which should be calibrated, then press “ZERO” to conduct zeroing, waiting
1~2 seconds, if value display as 0.0g, Zero is successfully done. If not, try it again.
• Put the poise in the weigh hopper gently and then press "Full" to confirm. Waiting 1~2 seconds, if value
same as poise weight, Calibration is done successfully.
• Repeat above operations to calibrate the rest of load cells.
Attention: Make sure there is no any products in weigh hopper. Calibration should be done in condition of
airless and no vibrating environment.

• 10 •
Multihead Weigher Operation Manual

5.4 Program Setup


On the main menu, press "Program Setup" to enter into the " Program Setup " menu , shown as chart 5-4-1.

Chart 5-4-1

1. Program No.:
Program No.: Choose the saved program number for different product. Range:1-99.
2. Prod. Name:
Products Name: Input the products' name. (6 letters Maximum).
3. Target Wt:
Target Weight: The target weight of products. Unit is gram. Range: 3.0-6000.0g.
4. Over Wt:
Over Weight: The over weight limit of the weighed products. Range: 0.0~99.9g, Unit is gram.
5. Under Wt:
Under Weight: The under weight limit of the weighed products. Range:0.0~99.9g, Unit is gram.
6. Correct Wt:
Correct Weight: It used as a correct value when the combination weigher can not be calibrated
amendatory value referring to the deviation between the actual weight and display weight. Actual weight=
Displayed weight - Correct weight. Range:-50.0g~+50.0g, Unit is gram.
7. Preset Sp:
Preset Speed: Set an expected speed for multihead weigher. It can be set according to the working
speed of the connected packaging machine.

• 11 •
Multihead Weigher Operation Manual

8. Zero Interval:
Zero Intervals: The load cell performs zeroing automatically after N times combination. This function aims
to remove error to ensure weighing accuracy. In Zero status, the hopper is cleared up and will not be
taking into combination. (Range:0-999 Minutes.)
9. Stable Tm:
Stable Time: After feed hopper closing, there is a stable time delay before system reading digital sensor
to make sure the accuracy of weighing. The bigger the value is, the slower the weighing speed is. (Range:
80-255*10ms, Recommendation: 95-125*10ms)
10. Min HP WT%:
Minimum Single Hopper Weight(%):It is a percentage to be set. If single hopper weight is less than certain
percentages of target weight, the hopper is not allowed to join combination and it needs feed more
material. And this hopper can attend the combination when reaching the certain percentage. (Range: 5-99,
Recommendation: 10-25)
11. IDLE:
No Combination Times: It refers to the times that the hopper not be combinated while running. If the times
that the hopper uncombinated exceeds the IDLE times preset. That hopper will be combinated forcibly.
This function can improve the using rate of weigh hoppers. (Range: 11-9999, Recommendation:50-100)
12. Multicomb TMS:
Multi-combination Times: When target weight is large, it will be divided into several times to discharge.
The timing hopper will open to dump the products into packaging equipment after collecting all the
products from the multi-combination times discharging. This function aims to solve big target weight, to
avoid product blocking or lower pass rate. (Range:1-99)
13. Level Feed Tm:
Level Products Feed Time: It refers the photo cell detect less or no products on weigher, feeding
signal will last the “Level Feed Tm “ to output until photo cell detect product again. (Range: 1-99*1s,
Recommendation:5-10)
14. Lin VB Dly:
Linear Vibrator Feed Delay: It refers the time delay that linear vibrator to feed product to feed hopper after
the feed hopper open. (If it is too short, products may be blocked in feed hopper, if it is too long, it will
affect weighing speed .(Range:1-250*10ms.Recommendation:10-35)
15. Feed HP Dly:
Feed Hopper Delay: It refers the time delay that feed hopper to feed products to weigh hopper after the
weigh hopper open and releasing the product. (Range:1-250*10ms.Recommendation:10-35)

• 12 •
Multihead Weigher Operation Manual

16. Weigh HP Dly:


Weigh Hopper Delay: It refers the time delay that the weigh hopper to dump products into the timing
hopper after the timing hopper open. (Range:1-250*10ms.Recommendation:10-35)
17. Time HP Dly:
Timing Hopper Delay: It refers the time delay that the timing hopper to discharge products into the
packaging machines after weigh hopper dumping the products to ensure all the materials in the timing
hopper and then allow next discharge. (Range:1-250*10ms.Recommendation:55-90)
18. Dump Sgl Tm:
Dump Signal Time:It refers the duration time that multihead weigher send dump signal to packaging
machine. (Range: 1-999*10ms. Recommendation: 10-30.)

Vibrator Settings
Press “Vibrator Settings” enter following menu, shown as Chart 5-4-2.

Chart 5-4-2

19. Main VB Feed Tm:


It means time that main vibrator acts. (Range: 20ms. Recommendation:5-20.)
20. Lin VB Feed Tm:
It means time that linear vibrators act. (Range: 20ms. Recommendation:5-20.)

• 13 •
Multihead Weigher Operation Manual

21. Set All:


Press this button; change all settings of linear vibrator.
In Menu“Program Setting1”, Press“Next”to enter to“Program Setting2”menu, shown as Chart 5-4-3.

Chart 5-4-3

22. FD HP MD:
Feed Hopper Mode: It refers to the running model of the feed hopper motor. There are 4 patterns for
choice. That is 0-3. The smaller the value is, the faster the speed is.(Recommend value: 0-2)
23. WG HP MD:
Weigh Hopper Mode: Set the motor pattern of weigh hopper. There are 4 patterns for choice that is 0-3.
The smaller the value is, the faster the speed is. (Recommend value:0-2)
24. Tm HP MD:
Timing Hopper Mode: Set the motor pattern of timing hopper mode, there are 4 patterns for choice, that
is 0-3. The smaller the value is, the faster the speed is ( Recommend value: 0-2)
25. FD HP Opn Tm:
Feed Hopper Open Time: After feed hopper open, there will be a "feed hopper open time" delay, and then
the feed hopper will close to ensure all the products are discharged. ( Range:1-999*10ms, Recommend
value:1-20)

• 14 •
Multihead Weigher Operation Manual

26. WG HP Opn Tm:


Weigh Hopper Open Time: After weigh hopper open, there will be a "weigh hopper open time" pause,
and then the weigh hopper will close to ensure all the products are discharged. ( Range:1-999*10ms,
Recommend value:1-20)
27. Tm HP Opn Tm:
Timing Hopper Open Time: After timing hopper open, there will be a "timing hopper open time" pause,
and then timing hopper will close to ensure all the products are discharged. ( Range:1-999*10ms,
Recommend value:1-20)
28. Single Pieces WT:
Single Piece Weight: The standard weight of single piece for uniform products which is applicable to
calculate the combination weight to finish the target pieces.
29. Target Pcs:
Target Pieces: The target pieces of the weighing products.
30. Over Pcs:
Over Piece Limit: The allowable up limit of the weighed products
31. Under Pcs:
Under Piece Limit: The allowable down limit of the weighed products.

Notes:
0: It means to close this function. The amplitude can only be adjusted by manual;
1: AFCT, it adjust the amplitude according to the combinated hoppers and it will give
an auto adjustment to all linear vibrator amplitudes;
2: AFCW, it adjust the amplitude according to the single hopper weight and it will give
an auto adjustment to the single linear amplitude, meanwhile, display the single amplitude.

• 15 •
Multihead Weigher Operation Manual

----------------AFCT----------------

33. Avg Comb Hps:


Avg Combination Hoppers: It refers the average combination hoppers which are used in a successful
combination weighing. (Range:0.1-9.9,Recommendation: 3.0-4.0 for 10head,5.0-7.0 for 14head)
34. Acpt Comb Err:
Single Acceptable Combination Error Hoppers: It refers to the acceptable deviation of average number of
combination hoppers. (Range:0.1-9.9,Recommendation:0.1~1.0)
35. Track Interval:
Track Interval: After N times successful combinations, it will give an auto adjustment to all linear
amplitudes. (Range:0.1-9.9,Recommendation:1.0)

----------------AFCW----------------

36. Avg HP Wt%:


Single Avg Hopper Weight Percent: It refers to the ideal average weight of single hopper, and it was
calculated as certain percentage of single combination weight. (Range:1~99,Recommendation: 20%-
40%.)
37. ACPT HP Wt Err:
Single Hopper Acceptable Error Weight: It refers to the single acceptable hopper weight error during
running. (Range:0.1~100.0,Recommendation:1.0-10.0g)
38. Track Interval:
Track Interval: After N times successful combinations, it will give an auto adjustment to the single linear
amplitude. (Range:1~99,Recommendation: 10)
39. Stagger Dump Tm:
This function aims to puffy food, like chips.It means that, each hopper of this combination will take turns
to discharge products via interval. Range 0-999*10ms.
40. Copy To:
Copy this Program to:The current parameter will be saved with another program number.

• 16 •
Multihead Weigher Operation Manual

5.5 System Setup


Press "System Setup" on main menu to enter "System Setup" menu, shown as chart 5-5-1.

Chart 5-5-1

1. Signal Type:
To preset the models of receiving discharging signal received from the packaging machine. Range: 0-4.
• 0: Trailing edge of pulse with memory: If multihead weigher receive a signal when it is not ready, it will
remember the signal and discharge to the packaging machine when it is ready.
• 1: Trailing edge of pulse without memory: If multihead weigher receive a signal when it is not ready, it
will not discharge when it is ready until it receive another request signal.
• 2: Tension with memory: If multihead weigher receive a signal when it is not ready, it will remember the
signal and discharge to the packaging machine when it is ready.
• 3: Tension without memory: If multihead weigher receive a signal when it is not ready, it will not
discharge when it is ready until it receive another request signal.
• 4: Rising edge of pulse without memory. If multihead weigher receive a signal when it is not ready, it will
not discharge when it is ready until it receive another request signal.

ATTN:Pulse signal is effective when it connects and breaks.


Tension signal is effective once it connect.

• 17 •
Multihead Weigher Operation Manual

2. Weighing MD:
Weighing Mode: Selection between weighing and counting by pieces. There are two model, 0~1, Default
value is 0.
• 0: Weighing. Unit is gram.
• 1: Counting by pieces. Unit is Pieces.)
3. Top Cone MD:
Top Cone Model: there are 4 model,
• 0: Vibrator+ Photocell (For easy flowing granule products)
• 1: Rotary+Photocell (For uneasy running products.)
• 2: Vibrator+ Load Cell (For easy flowing granule products)
• 3: Rotary +Load Cell (For uneasy running products.)
4. Tm HP Mode:
Timing Hopper Mode: 0~3
• 0: No timing hopper.
• 1: The two doors of timing hopper open at the same time
• 2: The two doors of timing hopper open by interval. (In the case of weigher connected with two packing
machines. High speed packaging)
• 3: The timing hopper + unqualified weight rejecter ,one door discharge to packing machine, the other
discharge to overweight rejecter.
5. No Comb Action:
No Combination Action: Select the processing ways in case of there is no any combination
• 0: Auto enforced dumping. If there is no any combination always, the weigher computer will recalculate
all combination and identifies the overweight closest to the target weight, discharge this overweight
products and output the "Overweight" signal.
• 1: Manual intervention. The weigher will stop running automatically, and display the notice "Pls do
manual intervention", after the status be settled down, the weigher computer will start to recombination.
6. Combn HPS:
Combined Hoppers: If there is no qualified combination, it will decide if re-feed products to recombine, or
make an enforced discharge according to the current actual combined hoppers.
7. Optimum:
This function aims to achieve higher accuracy. An idealist combination will be selected to discharge
among all qualified comtinations. Range:1-99.

• 18 •
Multihead Weigher Operation Manual

8. Starved Feeding Pause Delay:


When photocell detect no enough products on top cone, Weigher will stop within this Delay time until
elevator start to feed products, then weigher will start to work automatically. Unit is seconds.
Model “0”, this function is disabled.
9. Free port (1.2.3.):
Please select corresponding Free Port function via pull-down menu:
Free Port 1 match Signal wire Y07&Y08
Free Port2 match Signal wire Y11&Y12
Free Port3 match Signal wire Y13&Y14

Free port Setting Value Signal


0 No output
1 Discharge 1
2 Discharge 2
3 Ready 1
Free Port 1(Default value 8)
4 Ready 2
Free Port 2(Default value 9)
5 Feeding
Free Port 3(Default value 10)
6 Overweight 1
7 Overweight 2
8 Empty
9 Run
10 Pneumatic timing hopper

10. Combined Model:

• 19 •
Multihead Weigher Operation Manual

11. Sys Management:


System Management: Press this button to enter menu “Sys Management”, shown as chart 5-5-2

Chart 5-5-2

In this menu, machine Version Number and Software Version Number can be tracked.
Attention: “Default set 1”, “Default set 2” and “A/D” are all default plant parameters Please
contact our factory for any parameter’s modification.
Press “Exit” back to Menu “System Setup”.
12. Password Setup
Press this button to enter menu “Password Setup”, Shown as Chart 5-5-3

Chart 5-5-3

• 20 •
Multihead Weigher Operation Manual

A. Password for Program Setup: 138138; In case of customer want to reset password, please press“Exit”
,
the resetting password will work;
B. Password for Calibration: 168168; In case of customer want to reset password, please press “Exit”,
the resetting password will work;
C. Password for System Setup: 178178; In case of customer want to reset password, please press“Exit”
,
the resetting password will work;
Password including 6 numbers, just input once is available.
Press “Exit” back to Menu “System Setup”.
13. Download:
After you change the parameters in the program setup, you have to press "Download" to upload the
program in order to make the revised parameters work. Please press "Download" for at least 1 second
until the guage comes up.
14. Motor MD:
It is to set the running mode for different motors. Press "Motor MD Setup" enter "Motor MD Setup" menu,
shown as chart 5-5-4.

Chart 5-5-4

• 21 •
Multihead Weigher Operation Manual

1) FD HP MD: Feed Hopper Motor: Press "FD HP MD",4 modes to be choose. Range: 0.1.2.3.; Press
“Download” to save new setting;
2) WG HP MD: Weigh Hopper Motor: Press "WG HP MD",4 modes to be choose. Range: 0.1.2.3. ; Press
“Download” to save new setting;
3) TM HP MD: Time Hopper Motor: Press "TM HP MD",4 modes to be choose. Range: 0.1.2.3.; Press
“Download” to save new setting;
4) Init. Move DRCT: The rotary direction of front 5 moves (1~5).
• 0: Clockwise rotary.
• 1: Anticlockwise rotary.
5) Return Move DRCT: The rotary direction of return 5 moves (6~10).
• 0: Clockwise rotary.
• 1: Anticlockwise rotary.
6) Steps: It means that the step motor runs how many pulses within this segment, for each pulse, the
step motor rotary angle is 1.8° . Range:0~100
7) Speed: The rotary speed for each step within the segment. Rang: 0~99, the value is bigger, speed is
faster.
Attention: The total steps of Initial Move should be equal with Return Move.
8) Download: After you change the parameters, you must press "Download" to save the program, until
then the revised parameters will work. Please press "Download" for at least 1 second until the guage
comes up.
15. Prog. Recov:
Program Recovery: Press "Prog. Recov" until the guage window comes out . 1-15 sets of preset progrom
can be recovered.

• 22 •
Multihead Weigher Operation Manual

5.6 Record
On the main menu, press "Record" to enter the menu "Record" , shown as chart 5-6-1.

Chart 5-6-1

1. Total Records: Maximum 2000 pages of records could be saved. Input number to track each record.
2. Display Record: Press the button and input record number to check the corresponding record.
3. No Record:
4. Date Search:
Press the button and it will display the number keys. Input the date, it will display the last record of that
day.
5. Prev.: Show previous record.
6. Next: Show next record.
7. Print:
Plug the USB memory card into the touch screen and press "Print", then it will turn the present record
into JPG picture and be saved to the USB memory card. Then you can print it by computer.
8. Del. All:
Delete All Records: Press this button until the window comes out and the guage is over. Then all records
will be deleted.
9. Main Menu: Press the button and return back to the main menu.

• 23 •
Multihead Weigher Operation Manual

5.7 Manual Test


On the main menu, press "Manual Test" to enter the "Manual Test " interface, shown as chart 5-7-1.
"Manual Test" is mainly to check the running condition of each part.

Chart 5-7-1

1. Motor. Sensor:
Motor Sensor: Press this button to detect step motor back to original position (clockwise 6 o’clock), if
green light, means motor stay at original position; if red light, means motor not stay at original position.
Outer circle of light indicate feeding hopper motors,inner circle of light indicate weighing hopper motors,
center lights indicate timing hopper motors.

Chart 5-7-2

• 24 •
Multihead Weigher Operation Manual

2. Main VB:
Main Vibrator: Press any number button ,then press “Main VB”, main vibrator act once;
3. Linear VB:
Linear Vibrator:Press number button 1~10/14, means choose a vibrator, or press “Select All”, choose
all linear vibrators, then press “Linear VB”, Linear vibrators will act once;
4. Feed HP:
Feed Hopper: Press number button 1~10/14, means choose a feed hopper, or press “Select All”,
choose all feed hopper, then press “Feed HP”, Feed hopper will act once;
5. Weigh HP:
Weigh Hopper: Press number button 1~10/14, means choose a weigh hopper, or press “Select All”,
choose all weigh hopper, then press “Weigh HP”, Weigh hopper will act once;
6. Timing HP:
Timing Hopper: Press number button 1~2, means choose timing hopper open door by single side, or
press “Select All”, choose timing hopper open door by two sides, then Press “Timing HP” , Timing
hopper will act once;
7. Load cell
Press this button to test the status of A/D module. Shown as Chart 5-7-3 ,choose number
button1~10/14, long press at least 1second to make zeroing.

Chart 5-7-2

Note: hopper weight in green means load cell modular in good signal communication, in
red means signal communication in error.

• 25 •
Multihead Weigher Operation Manual

1. Disable HP:
Disable Hopper: Press this button and then select the number key to inhibit the corresponding hopper.

Once the hopper is inhibited, will change to "D". Long press the number key again to activate the

hopper and "D" will change to . This function is mainly applied to repair the failure hopper.
2. Once Run:
Press this button and then select the number key. The selected hopper will run once with the process
of main vibrator → linear vibrator → feed hopper → weigh hopper → timing hopper. Press "M" to select
all hoppers. If you keep pressing the "FULL" button, they will run continually. Press "Once Run" again to
exit.
3. Cont. Run:
Continuous Running: Press this button and then select the number key. The selected hopper will run
continuously with the process of main vibrator → linear vibrator → feed hopper → weigh hopper → timing
hopper. Press "FULL" to select all hoppers. Press "Cont. Run" again to exit.
4. Test Run:
Press this button, Weigher will run according to present parameter without real material. In this condition,
requested signal will input and other signal can be output/input to test signal communication between
weigher and packaging machine.

• 26 •
Multihead Weigher Operation Manual

Chapter 6. Trouble Shooting & Settlement


Bad Accuracy
Low Pass Rate
Fault reason Trouble shooting and Settlements
1. Adjust Amplitude or vibrating time,make AV Combi HP
as 3~5 (10head) 5~7(14head)
2. Adjust the height of uper funnel,make sure enough
1. AV Combi HP too much or too small product spreading on linear feeding pans, but prevent
over load
3. If use AFC, set AV Combi HP as 4
4. If use AFCW, set Min HP WT%: as 25
1. Feeding conveyor capacity not enough
2. Product feeding unevenly 2. Product feeding uncontiniously, adjust Starve feeding
Delay
1. Increase AV Combi HP will rise the accuracy while will
3. AV Combi HP too small
slow down the speed

Bad Accuracy
Big difference between display weight on HMI and actual weight
Fault reason Trouble shooting and Settlements
1. Airless working space
2. Weigher should be put on horizontal level, supporting
frame should be stable
1. Zero over floating,Load cell data jumping
3. Weigher should be surely grounded
4. If sticky product, auto-zero tracking time shoulbe be
reduced
1. Overweight:set Correct WT as minus
2. OverWT or UnderWT in actual weight Under weight: set Correct WT as plus
2. Recalibation
1. Increase Hopper delay time
3. Products be clamped by hopper
2. Increase Hopper open time

4. Products stick or be blocked on hopper 1. Check weighing hopper be touched by anything


hooks 2. Check any products stick in weighing hoppers

5. Parameter Setting 1. Increase Stable time

• 27 •
Multihead Weigher Operation Manual

Slow speed
Fault reason Trouble shooting and Settlements
1. Increase Preset Speed
2. Adjust Stable Time, Stable Time suggest value as 100-
1. Parameter Setting 120
3. Decrease Delay Time, meanwhile make sure products
couldn’t be clamped
1. Check weigher has send ready signal but not input
2. Request Signal Input not on time
Request Signal on time
1. Products feeding not enough,products spreading
level unevenly, lead to bad combination rate
2. Linear Amplitude setting too small, Hopper of “L”
too much, lead to quantities of Average Combination
3. Dumping uncontiniously Hoppers too much
3. OverWT or UnderWT setting too small, lower
combination rate
4. Targete weight setting too large lead to bad
combination rate

Hopper Status
Symbol Meaning Trouble shooting and Settlements
R Ready
D Hopper Disabled 1. In Manual Test, set “Disable Hopper”
Failure in Unit head 1. Check power supply of Unit head control Modular; cables and
E
control Modular wires be well connected
Failure in communication
T 1. Check COM connector well connected or not
of weighing Modular
1. In case of AFC=0, decrease the “LIN AMP”. Lin AMP, make
Single hopper weight
sure products be dispersed evenly
U exceeds the target
2. In case of AFC=1,increase “Avg Comb Hps”
weight
3. In case of AFC=2, decrease the value of “Avg HP Wt%”
1. Increase “ AV Comb HP”, Increase OverWT or UnderWT
No Comb Tm be dropped 2. Adjust Amplitude, make sure single weighing hopper
Q
enforcedly weight as 25~35% of target weight, and set AV Comb HP as
3~4(10head),5~7(14head)
Current Combination that
C
be chosen
Z Auto Zero 1. For easy running products, increase “AUTO ZERO” accordingly
A Product Feeding

• 28 •
Multihead Weigher Operation Manual

Chapter 7. The Meaning of the Indicated Color & Character


NO. Color Character Meanings
1 Purple C Be choose to combination
2 Black D The hopper is disabled
3 Red E Head modular control boards in communication error
Single hopper weight exceeds target weight and be forced to
4 Orange U
discharge
Single hopper weight is less than the preset
5 Light Blue L
“Min Single Hopper Weight”
6 Yellow Q Being forced to dump due to no combination
AD card in good communication before running
7 Green R
Ready for combination during running
8 Light Red T Error in AD card communication
9 Blue Z Auto Zeroing in the running
10 Azury A Feeding products

• 29 •
Multihead Weigher Operation Manual

Chapter 8. Remarks of P1& P2 Cable

• 30 •
Multihead Weigher Operation Manual

Chapter 9. Crate-Open & Check


9.1 Check the machine and spare parts under guide of Packing List.

9.2 Check if the following documents are attached with the machine:
① Instruction manual.
② Packing List.
③ Installation manual.

9.3 To avoid damage to the machine surface as opening the crate, the top
cover board should be removed firstly, then remove the siding wooden
boards carefully

• 31 •
Multihead Weigher Operation Manual

Chapter 10. Machine Structure


10.1 Main Components

1 Upper Storage Funnel 8 Discharge Chute


2 Main Vibrator Pan 9 Machine Frame
3 Main Vibrator 10 Discharge Funnel
4 Linear Vibrator Pan 11 Timing Hopper/Bucket
5 Linear Vibrator 12 Touch Screen
6 Feed Hopper 13 Actuator
8 Weigh Hopper

• 32 •
Multihead Weigher Operation Manual

10.2 External Specification


1. Packaging Dimension:
HS-H10 1090L*1130W*1830H (mm)
HS-H14 1130L*1130W*1830H (mm)
HS-H14L5.0 2300L*1530W*1721H (mm)
2. Packaging Weight:
HS-H10 420KG
HS-H14 480KG
HS-H14L5.0 800KG
3. Installation Size:
HS-H10 Shown as chart 10-2-1
HS-H14 Shown as chart 10-2-2
HS-H14L5.0 Shown as chart 10-2-3

Chart 10-2-1

• 33 •
Multihead Weigher Operation Manual

Chart 10-2-2

Chart 10-2-3

• 34 •
Multihead Weigher Operation Manual

10.3 Main Components


1. Weigh Hopper Installation
Shown as chart 10-3-1, put the fixed plate close to the retainer bracket and then put the upper support
bar in the upper position slot and push down until the lower support bar is in the lower position slot.
Check and make sure the hopper is on stale position after mounted.

Chart 10-3-1

• 35 •
Multihead Weigher Operation Manual

2. Feed Hopper Installation


Please refer to the installation instruction of weigh hopper.
3. Linear Vibrator Pan Installation
Linear Vibrator Pan: Shown as chart 10-3-2, loosen the locking handle, slanting insert section "a" of the
Vibrator Pan to section "b" of the Vibrator. Level the Vibrator Pan and tighten the locking handle.
NOTICE: Each Linear Vibrator Pan should be well installed without bumping with each other.

Chart 10-3-2

• 36 •

You might also like