TAL040
TAL040
TAL040
General characteristics
Insulation class H Excitation system 6-wire SHUNT AREP+
Winding pitch 2/3 (wind.6S - 6-wire / wind.6 - 12-wire) AVR type R120 R180
Number of wires 6 (12 option) Excitation system 12-wire (option) SHUNT AREP+
Protection IP 23 AVR type R120 R180
Altitude ≤ 1000 m Voltage regulation (**) ±1% ± 0.5 %
Overspeed 2250 R.P.M. Total Harmonic Distortion THD (***) in no-load < 3.5 %
Air flow 50 Hz 0.06 m3/s Total Harmonic Distortion THD (***) in linear load <5%
Air flow 60 Hz 0.07 m3/s Waveform: NEMA = TIF (***) < 50
AREP+ Short-circuit current = 2.7 In: 5 seconds (*) Waveform: I.E.C. = FHT (***) < 2%
(*) D350: 10 seconds (**) Steady state (***) Total harmonic distortion between phases, no-load or on-load (non-distorting)
95
95
90 88.6 88.9 90.7 90.7 90.5
86.9 88.8 89.7
90
85
84.4
80.1 83.9 83.3 85 86.6 86.9 86.1
80 83.1 82.9 85.6
80 82.3
75 77.4
70 kVA 75 kVA
0 2 4 6 8 10 12 0 5 10 15 20 25
95 95
88.9 88.5 88.1 91.3 91.3 91.2
90 88.1 90.2
90
85 82.8 85.1
87.4 87.8 87.1
83.8 83.5 85 86.7
80 82.1 81.4
79.9 83.1
75 80
70 kVA 75 kVA
0 5 10 15 0 5 10 15 20 25
% TAL 040 D
100
95
89.1 90.2 90.2 90.0
90
85 83.5
85.7 86.1 85.3 84.8
80 81.2
75
70 kVA
0 5 10 15 20
B C D E F B C D E F
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 10 20 30 40 50 0 10 20 30 40 50
Phase loading (SHUNT) - kVA at P.F. = 0.8 Phase loading (AREP+) - kVA at P.F. = 0.8
B C D E F B C D E F
30% 30%
25% 25%
20% 20%
Voltage rise
Voltage rise
15% 15%
10% 10%
5% 5%
0% 0%
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Load shedding (SHUNT) - kVA at P.F. = 0.8 Load shedding (AREP+) - kVA at P.F. = 0.8
B C D E F B C D E F
30% 30%
25% 25%
20%
Voltage drop
Voltage drop
20%
15% 15%
10% 10%
5% 5%
0% 0%
0 10 20 30 40 50 0 10 20 30 40 50
- For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
- For voltages other than 400V (Y), 230V (Δ) at 50 Hz, then kVA must be multiplied by (400/U)2 or (230/U)2.
95 95
90 88.5 89.0 89.0 90.7 90.9 90.8
86.4 89.3
90
85
84.5 84.2 83.9 85 83.4 86.6 87.3 86.8 86.5
80 78.7 83.2
75 80 81.6
76.6
70 kVA 75 kVA
0 5 10 15 0 5 10 15 20 25 30
95
95
89.0 88.9 91.2 91.5 91.4
90 87.7 88.7 89.8
90
85
81.7 88.2 87.8
84.1 84.4 85 84.0 87.4 87.5
80 83.4 82.8
79.2 82.4
75 80
70 kVA 75 kVA
0 5 10 15 20 0 5 10 15 20 25 30
% TAL 040 D
100
95
90.2 90.4 90.3
90 88.7
70 kVA
0 5 10 15 20 25
B C D E F B C D E F
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Phase loading (SHUNT) - kVA at P.F. = 0.8 Phase loading (AREP+) - kVA at P.F. = 0.8
B C D E F B C D E F
30% 30%
25% 25%
20% 20%
Voltage rise
Voltage rise
15% 15%
10% 10%
5% 5%
0% 0%
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35
Load shedding (SHUNT) - kVA at P.F. = 0.8 Load shedding (AREP+) - kVA at P.F. = 0.8
B C D E F B C D E F
30% 30%
25% 25%
20% 20%
Voltage drop
Voltage drop
15% 15%
10% 10%
5% 5%
0% 0%
0 10 20 30 40 50 0 10 20 30 40 50 60
- For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
- For voltages other than 480V (Y), 277V (Δ), 240V (YY) at 60 Hz, then kVA must be multiplied by (480/U)2 or (277/U)2 or (240/U)2.
1000
SHUNT
1
1 10 100 1000 5000
Time (ms)
1000
100
TAL 040 C AREP+
Symmetrical -------- In
Asymmetrical - - -
10
Current (A)
SHUNT
1
1 10 100 1000 5000
Time (ms)
1000
100
TAL 040 D AREP+
Symmetrical -------- In
Asymmetrical - - -
10
Current (A)
SHUNT
1
1 10 100 1000 5000
Time (ms)
1000
10
Current (A)
SHUNT
1
1 10 100 1000 5000
Time (ms)
1000
100
AREP+
TAL 040 F
In
Symmetrical --------
Asymmetrical - - -
10
Current (A)
SHUNT
1
1 10 100 1000 5000
Time (ms)
General characteristics
Insulation class H Excitation system SHUNT
Winding pitch 2/3 (wind. M) AVR type R121
Number of wires 4 Voltage regulation (*) ±1%
Protection IP 23 Total Harmonic Distortion THD (**) in no-load < 3.5 %
Altitude ≤ 1000 m Total Harmonic Distortion THD (**) in linear load <5%
Overspeed 2250 R.P.M. Waveform: NEMA = TIF (**) < 100
Air flow 0.06 m3/s (50 Hz) / 0.07 m3/s (60 Hz) Waveform: I.E.C. = FHT (**) <2%
(*) Steady state (**) Total harmonic distortion between phases, no-load or on-load (non-distorting)
25% 25%
Voltage droop
20% 20%
15% 15%
10% 10%
5% 5%
0% 0%
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Locked rotor kVA at PF : 0.9
Single-bearing dimensions
Detail of L L
XBG Ø 11 holes over Ø M
S.A.E. 5 LB LB
flange AH AH 212 49 Access to
349
terminals β°
Z Xg Z Xg 81 50 ω°
and AVR
Cable
outlet
213
Ø N - 0.127
Ø N - 0.127
130
Ø 53
- 0.05
Ø BX - 0.15
- 0.05
Ø BX - 0.15
+0
+0
373
ØP
ØP
+1
H -3
X Ø Y holes
4
equid over Ø U
80 Optional
AIR H = 180
AIR OUTLET AIR OUTLET
13
98 87.5 INLET A2
3 3 13 C2 123.5 A1
C 282
5.5 203 5.5 51
307
Ø 25
Ø 50
Ø 52
Ø 41
Ø 55
Lr
Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2)
Flex plate S.A.E. 6 ½ S.A.E. 7 ½ S.A.E. 8 S.A.E. 10
Type Xr Lr M J Xr Lr M J Xr Lr M J Xr Lr M J
TAL 040 B 211.7 428 25.5 0.078 211.7 428 25.7 0.080 243.5 428 26 0.085 238.3 428 26.5 0.096
TAL 040 C 211.7 428 25.5 0.078 211.7 428 25.7 0.080 243.5 428 26 0.085 238.3 428 26.5 0.096
TAL 040 C1 221.7 428 27.9 0.087 221.7 428 28.1 0.089 253.5 428 28.4 0.094 248.3 428 28.9 0.105
TAL 040 D 229.2 458 30.3 0.094 229.2 458 30.5 0.096 261 458 30.8 0.100 255.8 458 31.3 0.112
TAL 040 E 236.7 458 32.2 0.100 236.7 458 32.4 0.103 268.5 458 32.7 0.107 263.3 458 33.2 0.119
TAL 040 F 246.7 478 35.3 0.110 246.7 478 35.4 0.113 278.5 478 35.7 0.117 273.3 478 36.2 0.129
NOTE : Dimensions are for information only and may be subject to modifications. The torsional analysis of the transmission is imperative. All values are available
upon request.
Linkedin.com/company/leroy-somer
Twitter.com/Leroy_Somer_en
Facebook.com/LeroySomer.Nidec.en
YouTube.com/LeroySomerOfficiel
© Nidec 2020. The information contained in this brochure is for guidance only and does not form part of
any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development
and reserve the right to change the specification of their products without notice.
Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France.
Capital social : 38 679 664 €, RCS Angoulême 338 567 258.
5672 en - 2021.06 / n