MTU
MTU
MTU
G00.50f Optimizations
G00.50 Exhaust emission optimization without test - - - - - only for 1500 rpm, 3B,
G00.50a measurement results (acc. to TA-Luft regu- - - - - - only air charge air cooling
G00.50b lations, NOx < 1500 mg/m³ i.N.) - - - - -
G00.51 Exhaust emission optimization with test - - - - - only for 1500 rpm, 3B,
G00.51a measurement results and protocol (acc. to - - - - - only air charge air cooling
G00.51b TA-Luft regulations, NOx < 1500 mg/m³ i.N.) - - - - -
G00.62 Exhaust emission optimization with certification - - - - - only for 1800 rpm, necessary for
G00.62a label on engine (acc. to EPA 40 CFR 60 Tier 2 - - - - - use in USA and Canada
G00.62b Stationary Emergency, EPA 40 CFR 89 Tier 2 compliant - - - - -
or flexibility)
G00.19 Exhaust emissions ARAI-Indien (2004), Stage I - - - - - for Indian Market only
G00.19a (valid until 30.06.2014) with label
G01.51 M Electric starter and compressed air starter with - - - - in place of item G01.10
G01.51a electric starting valve (24 VDC, max. 30 bar) - -
G03.26 M Open crankcase without return to combustion air system in place of item G03.25
G03.61 S Set of connecting parts for interval pre-lubrication pump contained in item G03.60, in case of
customer supplied pre-lubrication pump
G04.11 S Set of dry-type air filters with pre-separator, - - - - for medium to heavy duty use
G04.11a safety element, contamination indicator, - - in place of item G04.10
G04.11b rain cap and mounting parts
G05.11 S Set of companion flanges (2x) with gaskets for in place of item G05.10
connection to exhaust elbow
G06.31 M V-belt fan drive, with belt tensioner, in place of item G06.30
without fan, selective fan speed:
G10.40 S 1 coolant level sensor with cable (5 m) l l l l l l air charge air cooling
G10.40a (Bedia sensor, magnetic-inductive) water charge air cooling
for installation in coolant circuit expansion tank
G10.41 S 1 coolant level sensor with cable (15 m) water charge air cooling
(Bedia sensor, magnetic-inductive)
for installation in coolant circuit expansion tank
G10.42 S 1 coolant level sensor with cable (25 m) water charge air cooling
(Bedia sensor, magnetic-inductive)
for installation in coolant circuit expansion tank
G15.39 Primer (not available for stock engines) in place of item G15.30
G16.00 Documentation
G16.10 S Set of standard documentation (Hardcopy German) l l l l l l
consisting of:
- Installation instruction
- Fuel regulations
- Operating instructions
G17.15 Calculation for the layout of the exhaust / cooling / only 1x for all identical
fuel piping system (for standard design) designs per order
(1x per system)
G18.00 Packing
G18.10 Container-transportation cradle for engine in l l l l l l
G18.10a PVC cover and crate for accessories
G60.03 Accessory prices are only valid concurrently with engine order.